Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction.
Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction.
复制标题
DOI:
10.1002/jmri.26201
复制
发表时间:
2018-12
期刊:
影响因子:
--
通讯作者:
Bernstein MA
中科院分区:
文献类型:
--
作者:
Tao AT;Shu Y;Tan ET;Trzasko JD;Tao S;Reid RD;Weavers PT;Huston J 3rd;Bernstein MA
Gradient non-linearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion weighted imaging. A gradient non-linearity correction (GNLC) method has been developed for whole body systems, but yet to be tested for the new compact 3T (C3T) scanner which exhibits more complex GNL due to its asymmetrical design. To assess the improvement of ADC quantification with GNLC for the C3T scanner. Phantom measurements and retrospective analysis of patient data. A diffusion quality control phantom with vials containing 0-30% polyvinylpyrrolidone in water was used. For in-vivo data, 12 patient exams were analyzed (median age =33). Imaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (TR = 10000 ms, TE = min, b = 1000 s/mm2) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000-10000 ms, TE = min, b = 1000s/mm2) sequence was used for two patient cases. The 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole body scanners. Cerebrospinal fluid and white matter ADCs were quantified for patient and compared to values in literature. Paired t-test and two-way ANOVA For all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post-GNLC were within 1% and 6% of values reported in literature respectively and were significantly different from the uncorrected data (p<0.05). This study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from literature.
登录
查看更多内容
DOI:
10.1002/jmri.24883
发表时间:
2015-10
期刊:
Journal of magnetic resonance imaging : JMRI
影响因子:
--
作者:
Newitt DC;Tan ET;Wilmes LJ;Chenevert TL;Kornak J;Marinelli L;Hylton N
通讯作者:
Hylton N
影响因子:
3.3
作者:
Malyarenko, Dariya I.;Ross, Brian D.;Chenevert, Thomas L.
通讯作者:
Chenevert, Thomas L.
影响因子:
3.3
作者:
Janke, A;Zhao, HW;Doddrell, DM
通讯作者:
Doddrell, DM
影响因子:
3.5
作者:
Tao, S.;Trzasko, J. D.;Bernstein, M. A.
通讯作者:
Bernstein, M. A.
影响因子:
5.7
作者:
Sener, RN
通讯作者:
Sener, RN