Does unrestrained single-chamber plethysmography provide a valid assessment of airway responsiveness in allergic BALB/c mice?
Does unrestrained single-chamber plethysmography provide a valid assessment of airway responsiveness in allergic BALB/c mice?
复制标题
无限制单腔体积描记法是否可以有效评估过敏性 BALB/c 小鼠的气道反应性?
DOI:
10.1186/1465-9921-10-61
复制
发表时间:
2009-07-03
影响因子:
5.8
通讯作者:
Zhong N
中科院分区:
文献类型:
--
作者:
Zhang Q;Lai K;Xie J;Chen G;Zhong N
BackgroundUnrestrained plethysmography has been used to monitor bronchoconstriction because of its ease of use and ability to measure airway responsiveness in conscious animals. However, its reliability remains controversial.ObjectiveTo investigate if unrestrained plethysmography could provide a valid interpretation of airway responsiveness in allergic BALB/c mice.MethodsOvalbumin sensitized BALB/c mice were randomized to receive either a single-dose Ovalbumin challenge (OVA-1D group) or a three-dose Ovalbumin challenge (OVA-3D group). The OVA-1D group was further divided into OVA-1D-I (measured invasively, using lung resistance as the index of responsiveness) and OVA-1D-N group (measured non-invasively, using Penh as the index of responsiveness). Similarly the OVA-3D group was divided into OVA-3D-I and OVA-3D-N groups based on the above methods. The control groups were sensitized and challenged with normal saline. Bronchial alveolar lavage fluid was taken and airway histopathology was evaluated for airway inflammation. Nasal responsiveness was tested with histamine challenge.ResultsCompared with controls, a significant increase in airway responsiveness was shown in the OVA-1D-N group (P < 0.05) but not in the OVA-1D-I group. Both OVA-3D-I and OVA-3D-N groups showed higher responsiveness than their controls (P < 0.05). The nasal mucosa was infiltrated by eosinophic cells in all Ovalbumin immunized groups. Sneezing or nasal rubbing in allergic groups appeared more frequent than that in the control groups.ConclusionPenh can not be used as a surrogate for airway resistance. The invasive measurement is specific to lower airway. Penh measurement (done as a screening procedure), must be confirmed by a direct invasive measurement specific to lower airway in evaluating lower airway responsiveness.
登录
查看更多内容
影响因子:
3.3
作者:
Lundblad, LKA;Irvin, CG;Bates, JHT
通讯作者:
Bates, JHT
影响因子:
5
作者:
Nakaya, Muneo;Dohi, Makoto;Kaga, Kimitaka
通讯作者:
Kaga, Kimitaka
影响因子:
15.9
作者:
Schwarze, J;Hamelmann, E;Gelfand, EW
通讯作者:
Gelfand, EW
DOI:
10.1164/ajrccm.156.3.9606031
发表时间:
1997-09-01
影响因子:
24.7
作者:
Hamelmann, E;Schwarze, J;Gelfand, EW
通讯作者:
Gelfand, EW
影响因子:
9.6
作者:
Brightling, CE
通讯作者:
Brightling, CE