All-optical forward-viewing photoacoustic probe for high-resolution 3D endoscopy.

All-optical forward-viewing photoacoustic probe for high-resolution 3D endoscopy.
复制标题

DOI:
10.1038/s41377-018-0070-5
复制
发表时间:
2018
期刊:
Light, science & applications
影响因子:
--
通讯作者:
Beard PC
Beard PC
中科院分区:
其他
文献类型:
--
作者:
Ansari R;Zhang EZ;Desjardins AE;Beard PC

文献摘要

参考文献

被引文献

相似文献

Please try later.
A miniature forward-viewing endoscopic probe that provides high-resolution 3D photoacoustic images is demonstrated. The probe is of outer diameter 3.2 mm and comprised of a transparent Fabry-Pérot (FP) polymer-film ultrasound sensor that is located at the distal end of a rigid optical fiber bundle. Excitation laser pulses are coupled simultaneously into all cores of the bundle and are transmitted through the FP sensor to provide wide-field tissue illumination at the distal end. The resulting photoacoustic waves are mapped in 2D by sequentially scanning the input end of the bundle with an interrogation laser beam in order to individually address different points on the FP sensor. In this way, the sensor acts as a high-density ultrasound array that is comprised of 50,000 individual elements, each of which is 12 µm in diameter, within the 3.2 mm diameter footprint of the probe. The fine spatial sampling that this affords, along with the wide bandwidth (f-3dB = 34 MHz) of the sensor, enables a high-resolution photoacoustic image to be reconstructed. The measured on-axis lateral resolution of the probe was depth-dependent and ranged from 45-170 µm for depths between 1 and 7 mm, and the vertical resolution was 31 µm over the same depth range. The system was evaluated by acquiring 3D images of absorbing phantoms and the microvascular anatomies of a duck embryo and mouse skin. Excellent image fidelity was demonstrated. It is anticipated that this type of probe could find application as a tool for guiding laparoscopic procedures, fetal surgery and other minimally invasive interventions that require a millimeter-scale forward-viewing 3D photoacoustic imaging probe. Doctors looking for minimally invasive imaging techniques for use during procedures such as colon cancer screening may soon use laser-generated ultrasound waves from photoacoustic devices. Researchers are increasingly trying to equip endoscopes, slender visualization and diagnostic instruments inserted into the body, with photoacoustics because ultrasound penetrates deeper into tissue than light. Paul Beard from University College London in the United Kingdom and colleagues have now developed the first photoacoustic endoscope that images in the same forward direction of endoscope travel. By capping multi-core fiber-optic cables with thin, transparent polymer films that sense ultrasound waves, the team’s approach avoids the need for separate and bulky detectors. A prototype device consisting of 50 000 individually addressable fiber-optic cores produced high-resolution images of microvascular network of samples including duck embryos and mouse skin.
DOI: 10.1364/ol.35.002892
发表时间: 2010-09-01
期刊: OPTICS LETTERS
影响因子: 3.6
作者:
Hsieh, Bao-Yu;Chen, Sung-Liang;Li, Pai-Chi
通讯作者: Li, Pai-Chi
DOI: 10.1038/nphoton.2015.22
发表时间: 2015-04-01
期刊: NATURE PHOTONICS
影响因子: 35
作者:
Jathoul, Amit P.;Laufer, Jan;Beard, Paul
通讯作者: Beard, Paul
DOI: 10.1016/j.gie.2014.12.051
发表时间: 2015-08-01
影响因子: 7.7
作者:
Matsuzaki, Ippei;Miyahara, Ryoji;Goto, Hidemi
通讯作者: Goto, Hidemi
DOI: 10.1038/s41566-017-0027-x
发表时间: 2017-11-01
期刊: NATURE PHOTONICS
影响因子: 35
作者:
Guggenheim, James A.;Li, Jing;Beard, Paul C.
通讯作者: Beard, Paul C.
DOI: 10.1148/radiol.2017172228
发表时间: 2018-05-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
Neuschler, Erin I.;Butler, Reni;Dogan, Basak E.
通讯作者: Dogan, Basak E.