Comparison of gross body fat-water magnetic resonance imaging at 3 Tesla to dual-energy X-ray absorptiometry in obese women.
Comparison of gross body fat-water magnetic resonance imaging at 3 Tesla to dual-energy X-ray absorptiometry in obese women.
复制标题
DOI:
10.1002/oby.20287
复制
发表时间:
2013-04
期刊:
影响因子:
6.9
通讯作者:
Welch, E. Brian
中科院分区:
文献类型:
--
作者:
Silver, Heidi J.;Niswender, Kevin D.;Kullberg, Joel;Berglund, Johan;Johansson, Lars;Bruvold, Morten;Avison, Malcolm J.;Welch, E. Brian
Improved understanding of how depot-specific adipose tissue mass predisposes to obesity-related comorbidities could yield new insights into the pathogenesis and treatment of obesity as well as metabolic benefits of weight loss. We hypothesized that three-dimensional contiguous “fat-water” MR imaging (FWMRI) covering the majority of a whole-body field of view (FOV) acquired at 3 Tesla (3T) and coupled with automated segmentation and quantification of amount, type and distribution of adipose and lean soft tissue would show great promise in body composition methodology. Precision of adipose and lean soft tissue measurements in body and trunk regions were assessed for 3T FWMRI and compared to DEXA. Anthropometric, FWMRI and DEXA measurements were obtained in twelve women with BMI 30–39.9 kg/m2. Test-retest results found coefficients of variation for FWMRI that were all under 3%: gross body adipose tissue (GBAT) 0.80%, total trunk adipose tissue (TTAT) 2.08%, visceral adipose tissue (VAT) 2.62%, subcutaneous adipose tissue (SAT) 2.11%, gross body lean soft tissue (GBLST) 0.60%, and total trunk lean soft tissue (TTLST) 2.43%. Concordance correlation coefficients between FWMRI and DEXA were 0.978, 0.802, 0.629, and 0.400 for GBAT, TTAT, GBLST and TTLST, respectively. While Bland Altman plots demonstrated agreement between FWMRI and DEXA for GBAT and TTAT, a negative bias existed for GBLST and TTLST measurements. Differences may be explained by the FWMRI FOV length and potential for DEXA to overestimate lean soft tissue. While more development is necessary, the described 3T FWMRI method combined with fully-automated segmentation is fast (<30 minutes total scan and post-processing time), noninvasive, repeatable and cost effective.
登录
查看更多内容
影响因子:
3.3
作者:
Doneva, Mariya;Boernert, Peter;Lustig, Michael
通讯作者:
Lustig, Michael
影响因子:
6.9
作者:
Bergman, Richard N.;Stefanovski, Darko;Buchanan, Thomas A.;Sumner, Anne E.;Reynolds, James C.;Sebring, Nancy G.;Xiang, Anny H.;Watanabe, Richard M.
通讯作者:
Watanabe, Richard M.
影响因子:
4.4
作者:
Kullberg, Joel;Johansson, Lars;Boernert, Peter
通讯作者:
Boernert, Peter
影响因子:
4.4
作者:
Machann, J;Thamer, C;Schick, F
通讯作者:
Schick, F
DOI:
10.1007/s12265-009-9101-1
发表时间:
2009-09-01
影响因子:
3.4
作者:
Nedungadi, Thekkethil P.;Clegg, Deborah J.
通讯作者:
Clegg, Deborah J.