The accuracy of Magnetic Resonance - Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy.
The accuracy of Magnetic Resonance - Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy.
复制标题
DOI:
10.1016/j.phro.2019.11.005
复制
发表时间:
2019-10
影响因子:
--
通讯作者:
McCallum HM
中科院分区:
文献类型:
--
作者:
Wyatt JJ;Brooks RL;Ainslie D;Wilkins E;Raven E;Pilling K;Pearson RA;McCallum HM
Magnetic Resonance (MR)-Only radiotherapy requires an on-treatment image verification method. This study investigated the accuracy of MR-Cone Beam Computed Tomography (CBCT) image matching. MR-CBCT matching was not clinically different to CT-CBCT (mean differences ⩽0.2 mm). MR-CBCT matching had similar (within 0.5 mm) inter-observer variability to CT-CBCT. Magnetic Resonance (MR)-Only radiotherapy requires a method for matching image with on-treatment Cone Beam Computed Tomography (CBCT). This study aimed to investigate the accuracy of MR-CBCT soft-tissue matching for prostate MR-only radiotherapy. Three patient cohorts were used, with all patients receiving MR and CT scans. For the first cohort (10 patients) the first fraction CBCT was automatically rigidly registered to the CT and MR scans and the MR-CT registration predicted using the MR-CBCT and CT-CBCT registrations. This was compared to the automatic MR-CT registration. For the second and third cohorts (five patients each) the first fraction CBCT was independently matched to the CT and MR by four radiographers, the MR-CBCT and CT-CBCT matches compared and the inter-observer variability assessed. The second cohort used a CT-based structure set and the third a MR-based structure set with the MR relabelled as a ‘CT’. The mean difference between predicted and actual MR-CT registrations was (s.e.m.). Radiographer MR-CBCT registrations were not significantly different to CT-CBCT, with mean differences in soft-tissue match and all except one difference . This was less than the MR-CBCT inter-observer limits of agreement (vertical, longitudinal, lateral), which were similar () to CT-CBCT. MR-CBCT soft-tissue matching is not significantly different to CT-CBCT. Relabelling the MR as a ‘CT’ does not appear to change the automatic registration. This suggests that MR-CBCT soft-tissue matching is feasible and accurate.
登录
查看更多内容
DOI:
10.1016/j.ijrobp.2017.06.006
发表时间:
2017-11-01
影响因子:
7
作者:
Persson, Emilia;Gustafsson, Christian;Jonsson, Joakim
通讯作者:
Jonsson, Joakim
影响因子:
2.6
作者:
McNair, Helen A.;Harris, Emma J.;Dearnaley, David P.
通讯作者:
Dearnaley, David P.
影响因子:
2.6
作者:
Khoo, V. S.;Joon, D. L.
通讯作者:
Joon, D. L.
影响因子:
2.1
作者:
Chen S;Quan H;Qin A;Yee S;Yan D
通讯作者:
Yan D
影响因子:
3.6
作者:
Doemer, Anthony;Chetty, Indrin J.;Movsas, Benjamin
通讯作者:
Movsas, Benjamin