Estimation of regional myocardial mass at risk based on distal arterial lumen volume and length using 3D micro-CT images.

Estimation of regional myocardial mass at risk based on distal arterial lumen volume and length using 3D micro-CT images.
复制标题

DOI:
10.1016/j.compmedimag.2008.05.002
复制
发表时间:
2008-09
影响因子:
5.7
通讯作者:
Molloi, Sabee
Molloi, Sabee
中科院分区:
工程技术2区
文献类型:
--
作者:
Le, Huy;Wong, Jerry T.;Molloi, Sabee

文献摘要

参考文献

被引文献

相似文献

The determination of regional myocardial mass at risk distal to a coronary occlusion provides valuable prognostic information for a patient with coronary artery disease. The coronary arterial system follows a design rule which allows for the use of arterial branch length and lumen volume to estimate regional myocardial mass at risk. Image processing techniques, such as segmentation, skeletonization, and arterial network tracking, are presented for extracting anatomical details of the coronary arterial system using micro-computed tomography (CT). Moreover, a method of assigning tissue voxels to their corresponding arterial branches is presented to determine the dependent myocardial region. The proposed micro-CT technique was utilized to investigate the relationship between the sum of the distal coronary arterial branch lengths and volumes to the dependent regional myocardial mass using a polymer cast of a porcine heart. The correlations of the logarithm of the total distal arterial lengths (L) to the logarithm of the regional myocardial mass (M) for the left anterior descending (LAD), left circumflex (LCX) and right coronary (RCA) arteries were log(L) = 0.73log(M)+ 0.09 (R= 0.78), log(L) = 0.82log(M)+ 0.05 (R= 0.77), and log(L) = 0.85log(M)+ 0.05 (R= 0.87)s, respectively. The correlation of the logarithm of the total distal arterial lumen volumes (V) to the logarithm of the regional myocardial mass for the LAD, LCX and RCA were log(V) = 0.93log(M)− 1.65 (R= 0.81), log(V) = 1.02log(M) −1.79 (R= 0.78), and log(V) = 1.17log(M)− 2.10 (R= 0.82), respectively. These morphological relations did not change appreciably for diameter truncations of 600 to 1400 µm. The results indicate that the image processing procedures successfully extracted information from a large 3D dataset of the coronary arterial tree to provide prognostic indications in the form of arterial tree parameters and anatomical area at risk.
DOI: 10.1161/01.hyp.31.1.440
发表时间: 1998-01-01
期刊: HYPERTENSION
影响因子: 8.3
作者:
Garcia-Sanz, A;Rodriguez-Barbero, A;Romero, JC
通讯作者: Romero, JC
DOI: 10.1161/hc4401.098435
发表时间: 2001-11-06
期刊: CIRCULATION
影响因子: 37.8
作者:
Molloi, S;Kassab, GS;Zhou, YF
通讯作者: Zhou, YF
DOI: 10.1118/1.595651
发表时间: 1985-01-01
期刊: MEDICAL PHYSICS
影响因子: 3.8
作者:
PARKER, DL;CLAYTON, PD;GUSTAFSON, DE
通讯作者: GUSTAFSON, DE
DOI: 10.1586/14779072.4.4.583
发表时间: 2006-07-01
影响因子: 2
作者:
Hoffmann, Martin H;Lessick, Jonathan
通讯作者: Lessick, Jonathan
DOI: 10.1007/bf02368424
发表时间: 1990-01-01
影响因子: 3.8
作者:
KING, RB;WEISSMAN, LJ;BASSINGTHWAIGHTE, JB
通讯作者: BASSINGTHWAIGHTE, JB