Performance Investigation of a Hospital-grade X-ray Tube-based Differential Phase-contrast Cone Beam CT System.

Performance Investigation of a Hospital-grade X-ray Tube-based Differential Phase-contrast Cone Beam CT System.
复制标题

DOI:
10.1117/12.911400
复制
发表时间:
2012-02-12
期刊:
Proceedings of SPIE--the International Society for Optical Engineering
影响因子:
--
通讯作者:
Conover D
Conover D
中科院分区:
其他
文献类型:
--
作者:
Yu Y;Ning R;Cai W;Liu J;Conover D

文献摘要

参考文献

被引文献

相似文献

差分相位衬度技术有望成为CT成像领域的下一个突破口。虽然传统的基于吸收的X射线CT成像在区分软组织方面效率不高,但相位对比技术具有很大的优势,因为它能够利用物体的相位信息产生更高的对比度图像。我们的长期目标是开发一种基于门架级X射线管差分相位对比锥束CT(DPC-CBCT)技术,在不增加剂量水平的情况下,能够在软组织成像中获得更高的对比噪声比(CNR)。在去年建成的微焦点系统的基础上,设计并搭建了台式医用X线管DPC-CBCT系统。DPC-CBCT系统由医用X射线管和源栅、高分辨率探测器、旋转模架、位相栅和分析栅组成。三维(3-D)位相系数被重建,为我们提供了比传统CBCT扫描更高的CNR,但剂量水平相当的图像。研究了该系统的三个重要方面:a)重建图像相对于剂量水平的CNR的系统性能;b)不同的相位步进方案(即5步到8步)对重建图像的影响;以及c)体模的放大倍率或位置对图像质量的影响,主要是对CNR的影响。这些调查是通过体模研究完成的。
Differential phase contrast technique could be the next breakthrough in the field of CT imaging. While traditional absorption-based X-ray CT imaging is inefficient at differentiating soft tissues, phase-contrast technique offers great advantage as being able to produce higher contrast images utilizing the phase information of objects. Our long term goal is to develop a gantry-based hospital-grade X-ray tube differential phase contrast cone-beam CT (DPC-CBCT) technology which is able to achieve higher contrast noise ratio (CNR) in soft tissue imaging without increasing the dose level. Based on the micro-focus system built last year, a bench-top hospital-grade X-ray tube DPC-CBCT system is designed and constructed. The DPC-CBCT system consists of an X-ray source, i.e. a hospital-grade X-ray tube and a source grating, a high-resolution detector, a rotating phantom holder, a phase grating and an analyzer grating. Three-dimensional (3-D) phase-coefficients are reconstructed, providing us with images enjoying higher CNR than, yet equivalent dose level to, a conventional CBCT scan. Three important aspects of the system are investigated: a) The The system’s performance in term of CNR of the reconstruction image with regard to dose levels, b) the impacts of different phase stepping schemes, i.e. 5 steps to 8 steps, in term of CNR on the reconstruction images, and c) the influence of magnification or position of the phantom on image quality, chiefly CNR. The investigations are accomplished via phantom study.
DOI: 10.1038/nphys265
发表时间: 2006-04-01
期刊: NATURE PHYSICS
影响因子: 19.6
作者:
Pfeiffer, F;Weitkamp, T;David, C
通讯作者: David, C
DOI: 10.1117/12.878492
发表时间: 2011-03-16
期刊: Proceedings of SPIE--the International Society for Optical Engineering
影响因子: --
作者:
Yu Y;Ning R;Cai W
通讯作者: Cai W
DOI: 10.1088/0031-9155/52/7/011
发表时间: 2007-04-07
影响因子: 3.5
作者:
Chou, Cheng-Ying;Anastasio, Mark A.;Zhong, Zhong
通讯作者: Zhong, Zhong
DOI: 10.1063/1.1146073
发表时间: 1995-12-01
影响因子: 1.6
作者:
Snigirev, A;Snigireva, I;Schelokov, I
通讯作者: Schelokov, I
DOI: 10.1063/1.1145931
发表时间: 1995-02-01
影响因子: 1.6
作者:
MOMOSE, A;TAKEDA, T;ITAI, Y
通讯作者: ITAI, Y