Retinal Anatomy and Electrode Array Position in Retinitis Pigmentosa Patients After Argus II Implantation: An International Study.
Retinal Anatomy and Electrode Array Position in Retinitis Pigmentosa Patients After Argus II Implantation: An International Study.
复制标题
DOI:
10.1016/j.ajo.2018.06.012
复制
发表时间:
2018-09
影响因子:
4.2
通讯作者:
Zacks DN
中科院分区:
文献类型:
--
作者:
Gregori NZ;Callaway NF;Hoeppner C;Yuan A;Rachitskaya A;Feuer W;Ameri H;Arevalo JF;Augustin AJ;Birch DG;Dagnelie G;Grisanti S;Davis JL;Hahn P;Handa JT;Ho AC;Huang SS;Humayun MS;Iezzi R Jr;Jayasundera KT;Kokame GT;Lam BL;Lim JI;Mandava N;Montezuma SR;Olmos de Koo L;Szurman P;Vajzovic L;Wiedemann P;Weiland J;Yan J;Zacks DN
To assess the retinal anatomy and array position in the Argus II Retinal Prosthesis recipients. Prospective, non-comparative cohort study Setting: international multicenter study Patients: Argus II recipients enrolled in the Post-Market Surveillance Studies. Procedures: Spectral-domain Optical Coherence Tomography images collected for the Surveillance Studies (NCT01860092 and NCT01490827) were reviewed. Baseline and postoperative macular thickness, electrode-retina distance (gap), optic disc-array overlap, and preretinal membrane presence were recorded at 1, 3, 6, and 12 months. Main Outcome Measures: Axial retinal thickness and axial gap along the array’s long axis (a line between the tack and handle), maximal retinal thickness and maximal gap along a B-scan near the tack, midline, and handle. Thirty-three patients from 16 surgical sites in the United States and Germany were included. Mean axial retinal thickness increased from month 1 through month 12 at each location, but reached statistical significance only at the array midline (p- value=0.007). The rate of maximal thickness increase was highest near the array midline (slope=6.02, p=0.004), compared to the tack (slope=3.60, p<0.001) or the handle (slope=1.93, p=0.368). The mean axial and maximal gaps decreased over the study period, and the mean maximal gap size decrease was significant at midline (p=0.032). Optic disc-array overlap was seen in the minority of patients. Preretinal membranes were common before and after implantation. Progressive macular thickening under the array was common and corresponded to decreased electrode-retina gap over time. By month 12, the array was completely apposed to the macula in approximately half of the eyes.
登录
查看更多内容
DOI:
10.3928/23258160-20161031-03
发表时间:
2016-11-01
期刊:
Ophthalmic surgery, lasers & imaging retina
影响因子:
--
作者:
Rachitskaya AV;Yuan A;Marino MJ;Reese J;Ehlers JP
通讯作者:
Ehlers JP
影响因子:
4.4
作者:
de Balthasar, Chloe;Patel, Sweta;Fine, Ione
通讯作者:
Fine, Ione
影响因子:
--
作者:
Santos, A;Humayun, MS;Milam, AH
通讯作者:
Milam, AH
影响因子:
3
作者:
Ahuja, A. K.;Yeoh, J.;daCruz, L.
通讯作者:
daCruz, L.
影响因子:
4.4
作者:
Schatz, Andreas;Arango-Gonzalez, Blanca;Gekeler, Florian
通讯作者:
Gekeler, Florian