Intraday variability of indicator and pathogenic viruses in 1-h and 24-h composite wastewater samples: Implications for wastewater-based epidemiology.
Intraday variability of indicator and pathogenic viruses in 1-h and 24-h composite wastewater samples: Implications for wastewater-based epidemiology.
复制标题
1小时和24小时复合废水样品中指示剂和致病病毒的日内变化:对废水流行病学的影响。
DOI:
10.1016/j.envres.2020.110531
复制
发表时间:
2021-03
影响因子:
8.3
通讯作者:
Korajkic A
中科院分区:
文献类型:
--
作者:
Ahmed W;Bivins A;Bertsch PM;Bibby K;Gyawali P;Sherchan SP;Simpson SL;Thomas KV;Verhagen R;Kitajima M;Mueller JF;Korajkic A
We monitored the concentration of indicator viruses crAssphage and pepper mild mottle virus (PMMoV) and human pathogen adenovirus (HAdV) in influent from a wastewater treatment plant in Brisbane, Australia in 1-h and 24-h composite samples. Over three days of sampling, the mean concentration of crAssphage gene copies (GC)/mL in 24-h composite samples did not differ significantly (p = 0.72-0.92), while for PMMoV GC/mL (p value range: 0.0002-0.0321) and HAdV GC/mL (p value range: 0.0028-0.0068) significant differences in concentrations were observed on one day of sampling compared to the other two. For all three viruses, the variation observed in 1-h composite samples was greater than the variation observed in 24-h composite samples. For crAssphage, in 54.1% of 1-h composite samples, the concentration was less than that observed in 24-h composite samples; whereas for PMMoV and HAdV the concentration was less in 79.2 and 70.9% of 1-h composite samples, respectively, compared to the relevant 24-h composite samples. Similarly, the concentration of crAssphage in 1-h compared to 24-h composite samples did not differ (p = 0.1082) while the concentrations of PMMoV (p < 0.0001) and HAdV (p < 0.0001) in 1-h composite samples were significantly different from 24-h composite samples. These results suggest that 24-h composite samples offer increased analytical sensitivity and decreased variability compared to 1-h composite samples when monitoring wastewater, especially for pathogenic viruses with low infection rates within a community. Thus, for wastewater-based epidemiology applications, 24-h composite samples are less likely to produce false negative results and erroneous public health information.
登录
查看更多内容
DOI:
10.1080/09603123.2013.769205
发表时间:
2013-12-01
影响因子:
3.2
作者:
Ganesh, Atheesha;Lin, Johnson
通讯作者:
Lin, Johnson
影响因子:
7.7
作者:
Lago, PM;Gary, HE;Cruz, RG
通讯作者:
Cruz, RG
影响因子:
2.7
作者:
Hamza, Hazem;Rizk, Neveen Magdy;Hamza, Ibrahim Ahmed
通讯作者:
Hamza, Ibrahim Ahmed
影响因子:
12.8
作者:
Madoux-Humery, Anne-Sophie;Dorner, Sarah;Prevost, Michele
通讯作者:
Prevost, Michele
影响因子:
9.8
作者:
Haramoto, Eiji;Malla, Bikash;Kitajima, Masaaki
通讯作者:
Kitajima, Masaaki