Intracranial Blood Flow Quantification by Accelerated Dual-venc 4D Flow MRI: Comparison With Transcranial Doppler Ultrasound.
Intracranial Blood Flow Quantification by Accelerated Dual-venc 4D Flow MRI: Comparison With Transcranial Doppler Ultrasound.
复制标题
通过加速双速度编码4D 流动磁共振成像进行颅内血流定量分析:与经颅多普勒超声的比较
DOI:
10.1002/jmri.28115
复制
发表时间:
2022-10
影响因子:
4.4
通讯作者:
Sorond, Farzaneh A.
中科院分区:
文献类型:
--
作者:
Mahinrad, Simin;Tan, Can Ozan;Ma, Yue;Aristova, Maria;Milstead, Andrew L.;Lloyd-Jones, Donald;Schnell, Susanne;Markl, Michael;Sorond, Farzaneh A.
Dual‐venc 4D flow MRI, recently introduced for the assessment of intracranial hemodynamics, may provide a promising complementary approach to well‐established tools such as transcranial Doppler ultrasound (TCD) and overcome some of their disadvantages. However, data comparing intracranial flow measures from dual‐venc 4D flow MRI and TCD are lacking. To compare cerebral blood flow velocity measures derived from dual‐venc 4D flow MRI and TCD. Prospective cohort. A total of 25 healthy participants (56 ± 4 years old, 44% female). A 3 T/dual‐venc 4D flow MRI using a time‐resolved three‐dimensional phase‐contrast sequence with three‐dimensional velocity encoding. Peak velocity measurements in bilateral middle cerebral arteries (MCA) were quantified from dual‐venc 4D flow MRI and TCD. The MRI data were quantified by two independent observers (S.M and Y.M.) and TCD was performed by a trained technician (A.L.M.). We assessed the agreement between 4D flow MRI and TCD measures, and the interobserver agreement of 4D flow MRI measurements. Peak velocity from MRI and TCD was compared using Bland–Altman analysis and coefficient of variance. Intraclass correlation coefficient (ICC) was used to assess MRI interobserver agreement. A P value < 0.05 was considered statistically significant. There was excellent interobserver agreement in dual‐venc 4D flow MRI‐based measurements of peak velocity in bilateral MCA (ICC = 0.97 and 0.96 for the left and right MCA, respectively). Dual‐venc 4D flow MRI significantly underestimated peak velocity in the left and right MCA compared to TCD (bias = 0.13 [0.59, −0.33] m/sec and 0.15 [0.47, −0.17] m/sec, respectively). The coefficient of variance between dual‐venc 4D flow MRI and TCD measurements was 26% for the left MCA and 22% for the right MCA. There was excellent interobserver agreement for the assessment of MCA peak velocity using dual‐venc 4D flow MRI, and ≤20% under‐estimation compared with TCD. 3 Stage 2
登录
查看更多内容
影响因子:
4.4
作者:
Markl, Michael;Harloff, Andreas;Frydrychowicz, Alex
通讯作者:
Frydrychowicz, Alex
影响因子:
3.3
作者:
Harloff, A.;Albrecht, F.;Markl, M.
通讯作者:
Markl, M.
DOI:
10.3174/ajnr.a3010
发表时间:
2012-09
期刊:
AJNR. American journal of neuroradiology
影响因子:
--
作者:
Chang W;Loecher MW;Wu Y;Niemann DB;Ciske B;Aagaard-Kienitz B;Kecskemeti S;Johnson KM;Wieben O;Mistretta C;Turski P
通讯作者:
Turski P
影响因子:
6.3
作者:
Rivera-Rivera, Leonardo A.;Turski, Patrick;Wieben, Oliver
通讯作者:
Wieben, Oliver
影响因子:
3.5
作者:
de Riva, Nicolas;Budohoski, Karol P.;Czosnyka, Marek
通讯作者:
Czosnyka, Marek