Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.
Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.
复制标题
DOI:
10.1088/0031-9155/61/24/8521
复制
发表时间:
2016-12-21
影响因子:
3.5
通讯作者:
Xing L
中科院分区:
文献类型:
--
作者:
Vernekohl D;Ahmad M;Chinn G;Xing L
X-ray fluorescence imaging is a promising imaging technique able to depict the spatial distributions of low amounts of molecular agents in vivo. Currently, the translation of the technique to preclinical and clinical applications is hindered by long scanning times as objects are scanned with flux-limited narrow pencil beams. The study presents a novel imaging approach combining x-ray fluorescence imaging with Compton imaging. Compton cameras leverage the imaging performance of XFCT and abolish the need of pencil beam excitation. The study examines the potential of this new imaging approach on the base of Monte-Carlo simulations. In the work, it is first presented that the particular option of slice/fan-beam x-ray excitation has advantages in image reconstruction in regard of processing time and image quality compared to traditional volumetric Compton imaging. In a second experiment, the feasibility of the approach for clinical applications with tracer agents made from gold nano-particles is examined in a simulated lung scan scenario. The high energy of characteristic x-ray photons from gold is advantageous for deep tissue penetration and has lower angular blurring in the Compton camera. It is found that Doppler broadening in the first detector stage of the Compton camera adds the largest contribution on the angular blurring; physically limiting the spatial resolution. Following the analysis of the results from the spatial resolution test, resolutions in the order of one centimeter are achievable with the approach in the center of the lung. The concept of Compton imaging allows to distinguish to some extend between scattered photons and x-ray fluorescent photons based on their difference in emission position. The results predict that molecular sensitivities down to 240 pM/l for 5 mm diameter lesions at 15 mGy for 50 nm diameter gold nano-particles are achievable. A 45-fold speed up time for data acquisition compared to traditional pencil beam XFCT could be achieved for lung imaging on cost of a small sensitivity decrease.
登录
查看更多内容
影响因子:
10.6
作者:
Pratx G;Chinn G;Olcott PD;Levin CS
通讯作者:
Levin CS
影响因子:
4.6
作者:
Feng, Peng;Cong, Wenxiang;Wang, Ge
通讯作者:
Wang, Ge
影响因子:
3.5
作者:
Poludniowski, G.;Landry, G.;Verhaegen, F.
通讯作者:
Verhaegen, F.
影响因子:
3.6
作者:
Pratx, Guillem;Carpenter, Colin M.;Xing, Lei
通讯作者:
Xing, Lei
影响因子:
10.6
作者:
Kuang, Yu;Pratx, Guillem;Xing, Lei
通讯作者:
Xing, Lei