A microarray biosensor for multiplexed detection of microbes using grating-coupled surface plasmon resonance imaging.

A microarray biosensor for multiplexed detection of microbes using grating-coupled surface plasmon resonance imaging.
复制标题

DOI:
10.1021/es201239f
复制
发表时间:
2012-01-03
影响因子:
11.4
通讯作者:
Lynes, Michael A.
Lynes, Michael A.
中科院分区:
环境科学与生态学1区
文献类型:
--
作者:
Marusov, Gregory;Sweatt, Andrew;Pietrosimone, Kathryn;Benson, David;Geary, Steven J.;Silbart, Lawrence K.;Challa, Sreerupa;Lagoy, Jacqueline;Lawrence, David A.;Lynes, Michael A.

文献摘要

参考文献

被引文献

相似文献

Grating-coupled surface plasmon resonance imaging (GCSPRI) utilizes an optical diffraction grating embossed on a gold-coated sensor chip to couple collimated incident light into surface plasmons. The angle at which this coupling occurs is sensitive to the capture of analyte at the chip surface. This approach permits the use of disposable biosensor chips that can be mass-produced at low cost and spotted in microarray format to greatly increase multiplexing capabilities. The current GCSPRI instrument has the capacity to simultaneously measure binding at over 1000 unique, discrete regions of interest (ROIs) by utilizing a compact microarray of antibodies or other specific capture molecules immobilized on the sensor chip. In this report, we describe the use of GCSPRI to directly detect multiple analytes over a large dynamic range, including soluble protein toxins, bacterial cells, spores, and viruses, in near real-time. GCSPRI was used to detect a variety of agents that would be useful for diagnostic and environmental sensing purposes, including macromolecular antigens, a non-toxic form of Pseudomonas aeruginosa exotoxin A (ntPE), Bacillus globigii, Mycoplasma hyopneumoniae, Listeria monocytogenes, Escherichia coli, and M13 bacteriophage. These studies indicate that GCSPRI can be used to simultaneously assess the presence of toxins and pathogens, as well as quantify specific antibodies to environmental agents, in a rapid, label-free and highly multiplexed assay requiring nanoliter amounts of capture reagents.
DOI: 10.1063/1.1794378
发表时间: 2004-09-27
影响因子: 4
作者:
Ilic, B;Yang, Y;Craighead, HG
通讯作者: Craighead, HG
DOI: 10.1371/journal.ppat.1000557
发表时间: 2009-10
期刊: PLoS pathogens
影响因子: 6.7
作者:
Haagmans BL;Andeweg AC;Osterhaus AD
通讯作者: Osterhaus AD
DOI: 10.1016/j.jviromet.2004.06.019
发表时间: 2004-10-01
影响因子: 3.1
作者:
Boltovets, PM;Snopok, BA;Shirshov, YM
通讯作者: Shirshov, YM
DOI: 10.1016/s0022-1759(00)00295-7
发表时间: 2000-12-01
影响因子: 2.2
作者:
Gómara, MJ;Ercilla, G;Haro, I
通讯作者: Haro, I
DOI: 10.1007/5346_014
发表时间: 2006-01-01
期刊: SURFACE PLASMON RESONANCE BASED SENSORS
影响因子: --
作者:
Homola, Jiri;Piliarik, Marek
通讯作者: Piliarik, Marek