Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.
Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.
复制标题
DOI:
10.1021/acs.analchem.7b00991
复制
发表时间:
2017-06-06
影响因子:
7.4
通讯作者:
Easley CJ
中科院分区:
文献类型:
--
作者:
Negou JT;Avila LA;Li X;Hagos TM;Easley CJ
Fluorescence is widely used for small-volume analysis and is a primary tool for on-chip detection in microfluidic devices, yet additional expertise, more elaborate optics, and phase-locked detectors are needed for ultrasensitive measurements. Recently, we designed a microfluidic analog to an optical beam chopper (μChopper) that alternated formation of picoliter volume sample and reference droplets. Without complex optics, the device negated large signal drifts (1/f noise), allowing absorbance detection in a mere 27 μm optical path. Here, we extend the μChopper concept to fluorescence detection with standard wide-field microscope optics. Precision of droplet control in the μChopper was improved by automation with pneumatic valves, allowing fluorescence measurements to be strictly phase locked at 0.04 Hz bandwidth to droplets generated at 3.50 Hz. A detection limit of 12 pM fluorescein was achieved when sampling 20 droplets, and as few as 310 zeptomoles (3.1 × 10−19 mol) were detectable in single droplets (8.8 nL). When applied to free fatty acid (FFA) uptake in 3T3-L1 adipocytes, this μChopper permitted single-cell FFA uptake rates to be quantified at 3.5 ± 0.2 × 10−15 mol cell−1 for the first time. Additionally, homogeneous immunoassays in droplets exhibited insulin detection limits of 9.3 nM or 190 amol (1.9 × 10−16 mol). The combination of this novel, automated μChopper with lock-in detection provides a high-performance platform for detecting small differences with standard fluorescence optics, particularly in situations where sample volume is limited. The technique should be simple to implement into a variety of other droplet fluidics devices.
登录
查看更多内容
影响因子:
15.9
作者:
Kahn, BB;Flier, JS
通讯作者:
Flier, JS
DOI:
10.1039/c4an01725k
发表时间:
2015-02-21
期刊:
The Analyst
影响因子:
--
作者:
Godwin LA;Brooks JC;Hoepfner LD;Wanders D;Judd RL;Easley CJ
通讯作者:
Easley CJ
DOI:
10.1039/c6an01055e
发表时间:
2016-10-21
期刊:
The Analyst
影响因子:
--
作者:
Brooks JC;Ford KI;Holder DH;Holtan MD;Easley CJ
通讯作者:
Easley CJ
影响因子:
14.8
作者:
Mazutis, Linas;Gilbert, John;Ung, W. Lloyd;Weitz, David A.;Griffiths, Andrew D.;Heyman, John A.
通讯作者:
Heyman, John A.
影响因子:
7.4
作者:
Deal, Kennon S.;Easley, Christopher J.
通讯作者:
Easley, Christopher J.