A comparison of the quasi-static mechanical and non-linear viscoelastic properties of the human semitendinosus and gracilis tendons.
A comparison of the quasi-static mechanical and non-linear viscoelastic properties of the human semitendinosus and gracilis tendons.
复制标题
DOI:
10.1016/j.clinbiomech.2009.12.007
复制
发表时间:
2010-05
期刊:
影响因子:
--
通讯作者:
Kilger R
中科院分区:
文献类型:
--
作者:
Abramowitch SD;Zhang X;Curran M;Kilger R
Over fifty-percent of anterior cruciate ligament reconstructions are performed using semitendinosus and gracilis tendon autografts. Despite their increased use, there remains little quantitative data on their mechanical behavior. Therefore, the objective of this study was to investigate the quasi-static mechanical and nonlinear viscoelastic properties of human semitendinosus and gracilis tendons, as well as the variation of these properties along their length. Specimens were subjected to a series of uniaxial tensile tests: one-hour static stress-relaxation test, 30-cycle cyclic stress-relaxation test and load to failure test. To describe the nonlinear viscoelastic behavior, the quasi-linear viscoelastic theory was utilized to model data from the static stress relaxation experiment. The constants describing the viscoelastic behavior were similar between the proximal and distal halves of the gracilis tendon. The proximal half of the semitendinosus tendon, however, had a greater viscous response than its distal half, which was also significantly higher than the proximal gracilis tendon. In terms of the quasi-static mechanical properties, the properties were similar between the proximal and distal halves of the semitendinosus tendon. However, the distal gracilis tendon showed a significantly higher tangent modulus and ultimate stress compared to its proximal half, which was also significantly higher than the distal semitendinosus tendon. The results of this study demonstrate differences between the semitendinosus and gracilis tendons in terms of their quasi-static mechanical and nonlinear viscoelastic properties. These results are important for establishing surgical preconditioning protocols and graft selection.
登录
查看更多内容
影响因子:
3.8
作者:
Makihara, Y;Nishino, A;Kanamori, A
通讯作者:
Kanamori, A
影响因子:
4.8
作者:
Pinczewski, LA;Deehan, DJ;Clingeleffer, A
通讯作者:
Clingeleffer, A
DOI:
10.1115/1.1351889
发表时间:
2001-04-01
影响因子:
1.7
作者:
Donahue, TLH;Gregersen, C;Howell, SM
通讯作者:
Howell, SM
影响因子:
2.4
作者:
Moon, DK;Woo, SLY;Abramowitch, SD
通讯作者:
Abramowitch, SD
影响因子:
4.8
作者:
Freedman, KB;D'Amato, MJ;Bach, BR
通讯作者:
Bach, BR