Multisequence-imaging protocols to detect cortical lesions of patients with multiple sclerosis: observations from a post-mortem 3 Tesla imaging study.
Multisequence-imaging protocols to detect cortical lesions of patients with multiple sclerosis: observations from a post-mortem 3 Tesla imaging study.
复制标题
DOI:
10.1016/j.jns.2009.03.021
复制
发表时间:
2009-07-15
影响因子:
4.4
通讯作者:
McFarland, Henry
中科院分区:
文献类型:
--
作者:
Bagnato, Francesca;Yao, Bing;Cantor, Fredric;Merkle, Hellmut;Condon, Ellen;Montequin, Marcela;Moore, Sandra;Quezado, Martha;Tkaczyk, Deborah;McFarland, Henry
Neocortical lesions (NLs) are an important component of multiple sclerosis (MS) pathology and may account for part of the physical and cognitive disability. Visualizing NLs of patients with MS using magnetic resonance imaging (MRI) poses several significant challenges. We optimized the inversion time (TI) of T1-based magnetization-prepared rapid acquisition gradient-echo (MPRAGE) images by suppressing the signal of the lesions and enhancing their appearance as hypointensities, on the basis of the derived quantitative T1 measurements. The latter were achieved by the means of 2D inversion recovery fast spin echo (IR-FSE), repeated using different inversion times (TI). Comparisons of detection of NLs by MPRAGE and dual echo T2 and proton density-weighted (PDW) images were made. Four coronal brain slices from a deceased MS patient and two coronal brain slices from two formerly healthy donors were imaged using a 3 Tesla magnet (3T) equipped with a multi-channel coil. Based upon the averaged T1 values computed from the MS specimen as well as visual inspection, an optimal TI of 380 msec was selected for the MPRAGE image. No NLs were seen in the specimens of the two healthy donors. Of the 40 total NLs observed, 8 (20%) were visible in all three sequences employed. Three (7.5%) NLs were visible only in the PDW image and 5 (12.5%) were seen only in the T2W image. Four NLs (10%) had clearly unique conspicuity in the MPRAGE image. Of those, 3 were retrospectively scored in the PDW image (1 NL) or in the T2W image (2 NLs). We conclude that for the detection of MS-related NLs, high resolution T1-based MPRAGE and T2-W images offer complementary information and the combination of the two image sequences is crucial for increasing the sensitivity of detecting MS-induced NLs.
登录
查看更多内容
影响因子:
3.3
作者:
Deoni, SCL;Peters, TM;Rutt, BK
通讯作者:
Rutt, BK
影响因子:
5.9
作者:
Papanikolaou, N;Papadaki, E;Gourtsoyiannis, N
通讯作者:
Gourtsoyiannis, N
影响因子:
19.7
作者:
Vrenken, Hugo;Geurts, Jeroen J. G.;Pouwels, Petra J. W.
通讯作者:
Pouwels, Petra J. W.
影响因子:
5.7
作者:
Yao B;Li TQ;Gelderen Pv;Shmueli K;de Zwart JA;Duyn JH
通讯作者:
Duyn JH
DOI:
10.1073/pnas.0610821104
发表时间:
2007-07-10
影响因子:
11.1
作者:
Duyn, Jeff H.;van Gelderen, Peter;Fukunaga, Masaki
通讯作者:
Fukunaga, Masaki