课题基金 / 基金详情

Surgical robot with visual servo control by intra-operative images and distributed system architecture

Surgical robot with visual servo control by intra-operative images and distributed system architecture
通过术中图像和分布式系统架构进行视觉伺服控制的手术机器人
批准号:
13558103
负责人:
DOHI Takeyosh
金额:
$8.83万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (B)
财政年份:
2001
资助国家:
日本
项目状态:
已结题
起止时间:
2001 至 2003

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Use of intra-operative image for surgical guidance, referred as image-guided surgery, has been the focus of interest to achieve minimally invasive surgery and remote surgery. Often the patient motion during the surgery induces the discrepancy between actual location of the cured lesion and that in the pre-planned location in pre-operative images, which are problematic to achieve highly accurate robotics surgery. Based on the background above, the specific aim of this study is to develop image processing and control method to detect the target location in the intra-operative images and update robot control, by disciplinary integration of surgical robotics and medical image processing.As the first set of this study, a real-time ultrasound-guided needle insertion medical robot for percutaneous cholecystostomy has been developed. The proposed instrument uses ultrasound images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique In phantom and v … More olunteer experiments, the needle path update times were 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target. The second set of this study was the application of navigator echo and projection profile matching to fast two-dimensional image registration for MR-guided liver robotic therapy. We obtain navigator echoes along the read-out and phase-encoding directions by using modified gradient echo imaging. This registration is made possible by masking out the liver profile from the image and performing profile matching with cross-correlation or mutual informaLion as similarity measures. Both the phantom and volunteer study indicate that this method can in 34 ms with root-mean-square error of 1.6 mm when the given misalignment of a liver is 30 mm.In conclusion, both stun perform registratiodies indicated the positive of intra-operative image guidance for aspects robotic control, and showed feasibility to apple the technology in realistic surgical setting. Less
期刊论文(33)
专著(0)
科研奖励(0)
会议论文
Junichi Tokuda, Takeyoshi Dohi, Nobuhiko Hata, et al.: "Motion tracking in MR-guided liver by using navigator echoes and projection profile matching"Academic Radiology. Vol.11, No.1. 111-120 (2004)
Junichi Tokuda、Takeyoshi Dohi、Nobuhiko Hata 等人:“通过使用导航回波和投影轮廓匹配进行 MR 引导肝脏运动跟踪”学术放射学。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Nakajima S, Nakamura K, Masamune K, Sakuma I, Dohi T.: "Three-dimensional medical imaging display with computer-generated integral photography"Comput Med Imaging Graph. 25(3). 235-241 (2001)
Nakajima S、Nakamura K、Masamune K、Sakuma I、Dohi T.:“计算机生成积分摄影的三维医学成像显示”计算机医学成像图。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
大橋晃太, 波多伸彦, 松村有子, 緒方徹, 佐久間一郎, 矢作直樹, 土肥健純: "骨穿孔小型軟性ドリルを用いた骨髄移植用 造血幹細胞採取マニピュレータの開発"日本コンピュータ外科学会誌. (印刷中). (2003)
Kota Ohashi、Nobuhiko Hata、Yuko Matsumura、Toru Ogata、Ichiro Sakuma、Naoki Yahagi、Kenzumi Doi:“开发使用小型骨钻小软钻进行骨髓移植的造血干细胞采集机械手”日本计算机学会杂志手术(正在出版)(2003)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Nakajima S, Nakamura K, Masamune K, Sakuma I, Dohi T.: "Development of a tracking method fo image analysis of time-l apse deformation of trabecular structure in a human bone"Comput Med Imaging Graph. 25(5). 443-448 (2001)
Nakajima S、Nakamura K、Masamune K、Sakuma I、Dohi T.:“开发人骨小梁结构时移变形图像分析跟踪方法”计算机医学成像图。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
18