DEVELOPMENT OF QUALITY CONTROL SYSTEM FOR DIAGNOSTIC X-RAY UNITS TO AIM REDUCTION OF PATIENT DOSE

DEVELOPMENT OF QUALITY CONTROL SYSTEM FOR DIAGNOSTIC X-RAY UNITS TO AIM REDUCTION OF PATIENT DOSE
开发诊断 X 射线设备的质量控制系统以减少患者剂量
批准号:
15590458
负责人:
MATSUMOTO Masao
金额:
$2.24万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2003
资助国家:
日本
项目状态:
已结题
起止时间:
2003 至 2004

项目摘要

项目成果

MATSUMOTO Masao的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
The purpose of this study is to measure diagnostic x-ray spectra using a high resolution Schottky CdTe detector (TOYO MEDIC RAMTEC 413A) and to determine the best response function of CdTe detector for correcting the measured spectra with using a rise time discrimination (RTD) circuit to primary x-ray spectra. Since the measured spectra were distorted by the response of CdTe detector and did not present the true photon spectra, the correction by the stripping procedure was applied. The response function of CdTe detector has been determined by using Monte Carlo simula-tion method for calculating the photon interaction (K-escape, coherent scattering and Compton scattering) and incomplete charge collection by trapping of hole and use of RTD circuit. This simulation performed with various important factors (mean path length. λ_h of hole and weight factor W_q of incomplete charge collection) for finding the best response function. The photon spectra corrected with those various response functions were compared with the corrected photon spectra measured using a high purity Ge (HP-Ge) detector (PRINCETON GAMMA-TECH NIGP1013345), and the Al-attenuation curves calculated from corrected spectra and measured using the HP-Ge detector were compared. The best-fitted response function was determined, and the attenuation curves calculated from the spectra corrected with this response function were agreed with that measured using the HP-Ge detector within maximum error 0.03 of the attenuation rate and 5.0 % of the half value layer.
期刊论文(42)
专著(0)
科研奖励(0)
会议论文
前田浩志, 松本政雄, 谷口明, 金森仁志: "高分解能CdTe検出器で測定した診断用X線スペクトルの補正"医学物理. 23Sup.2. 305-308 (2003)
Hiroshi Maeda、Masao Matsumoto、Akira Taniguchi、Hitoshi Kanamori:“用高分辨率 CdTe 探测器测量的诊断 X 射线光谱的校正”医学物理 23Sup.2 (2003)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
DOI: 10.1118/1.1921647
发表时间: 2005-06-01
期刊: MEDICAL PHYSICS
影响因子: 3.8
作者: [Maeda, K, Matsumoto, M, Taniguchi, A]
通讯作者: Taniguchi, A
Real-time estimation system for mean glandular dose in mammography
乳腺X线摄影平均腺体剂量实时估计系统
DOI: --
发表时间: 2003
期刊: Radiation Medicine 21・6
影响因子: --
作者: [M.Matsumoto, S.Inoue, I.Honda, S.Yamamoto, T.Ueguchi, Y.Ogata, T.Jokoh]
通讯作者: T.Jokoh
X-ray spectrum of CT system acquired by Compton spectroscopy using high resolution Schottky CdTe detector
使用高分辨率肖特基 CdTe 探测器通过康普顿光谱获取 CT 系统的 X 射线光谱
DOI: --
发表时间: 2005
期刊: Physics of Medical Imaging. SPIE proc. 5745(in press)
影响因子: --
作者: [K.Maeda, M.Matsumoto]
通讯作者: M.Matsumoto
14
    Development of quality control system of computed tomographic X-ray unit to decrease patient dose in diagnosis
    • 批准号:
      12557223
    • 项目类别:
      Grant-in-Aid for Scientific Research (B)
    • 资助金额:
      $4.1万
    • 财政年份:
      2000
    • 负责人:
      MATSUMOTO Masao
    • 依托单位:
    Development of quaity control system of mammographic X-ray unit to decrease patiant dose in mammography
    • 批准号:
      11672242
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $1.98万
    • 财政年份:
      1999
    • 负责人:
      MATSUMOTO Masao
    • 依托单位:
    Study of measuring system of x-ray spectrum for reduction of patient dose at medical x-ray diagnosis.
    • 批准号:
      08672583
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $1.47万
    • 财政年份:
      1996
    • 负责人:
      MATSUMOTO Masao
    • 依托单位:
    The Comparative Study of the Gegel's and Fichte's Concept-Theory