DEVELOPMENT OF QUALITY CONTROL SYSTEM FOR DIAGNOSTIC X-RAY UNITS TO AIM REDUCTION OF PATIENT DOSE
开发诊断 X 射线设备的质量控制系统以减少患者剂量
基本信息
- 批准号:15590458
- 负责人:
- 金额:$ 2.24万
- 依托单位:
- 依托单位国家:日本
- 项目类别:Grant-in-Aid for Scientific Research (C)
- 财政年份:2003
- 资助国家:日本
- 起止时间:2003 至 2004
- 项目状态:已结题
- 来源:
- 关键词:
项目摘要
The purpose of this study is to measure diagnostic x-ray spectra using a high resolution Schottky CdTe detector (TOYO MEDIC RAMTEC 413A) and to determine the best response function of CdTe detector for correcting the measured spectra with using a rise time discrimination (RTD) circuit to primary x-ray spectra. Since the measured spectra were distorted by the response of CdTe detector and did not present the true photon spectra, the correction by the stripping procedure was applied. The response function of CdTe detector has been determined by using Monte Carlo simula-tion method for calculating the photon interaction (K-escape, coherent scattering and Compton scattering) and incomplete charge collection by trapping of hole and use of RTD circuit. This simulation performed with various important factors (mean path length. λ_h of hole and weight factor W_q of incomplete charge collection) for finding the best response function. The photon spectra corrected with those various response functions were compared with the corrected photon spectra measured using a high purity Ge (HP-Ge) detector (PRINCETON GAMMA-TECH NIGP1013345), and the Al-attenuation curves calculated from corrected spectra and measured using the HP-Ge detector were compared. The best-fitted response function was determined, and the attenuation curves calculated from the spectra corrected with this response function were agreed with that measured using the HP-Ge detector within maximum error 0.03 of the attenuation rate and 5.0 % of the half value layer.
本研究的目的是使用高分辨率肖特基CdTe探测器(TOYO MEDIC RAMTEC 413 A)测量诊断X射线谱,并确定CdTe探测器的最佳响应函数,用于使用上升时间鉴别(RTD)电路对初级X射线谱进行校正。由于测量的光谱被CdTe探测器的响应所扭曲,并且不呈现真实的光子光谱,因此应用剥离程序进行校正。本文用Monte Carlo模拟方法计算了CdTe探测器的光子相互作用(K-逃逸、相干散射和康普顿散射)和空穴俘获引起的不完全电荷收集,并利用RTD电路确定了探测器的响应函数。该模拟使用各种重要因素(平均路径长度)进行。孔的λ_h和不完全电荷收集的权重因子W_q)来寻找最佳响应函数。将用这些不同响应函数校正的光子光谱与使用高纯度Ge(HP-Ge)检测器(PRINCETON GAMMA-TECH NIGP 1013345)测量的校正的光子光谱进行比较,并且将从校正的光谱计算的Al衰减曲线与使用HP-Ge检测器测量的Al衰减曲线进行比较。确定了最佳拟合的响应函数,用此响应函数校正后的衰减曲线与HP-Ge探测器测量的衰减曲线在衰减率的最大误差为0.03和半值层的5.0%以内一致。
项目成果
期刊论文数量(42)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
前田浩志, 松本政雄, 谷口明, 金森仁志: "高分解能CdTe検出器で測定した診断用X線スペクトルの補正"医学物理. 23Sup.2. 305-308 (2003)
Hiroshi Maeda、Masao Matsumoto、Akira Taniguchi、Hitoshi Kanamori:“用高分辨率 CdTe 探测器测量的诊断 X 射线光谱的校正”医学物理 23Sup.2 (2003)。
- DOI:
- 发表时间:
- 期刊:
- 影响因子:0
- 作者:
- 通讯作者:
Compton-scattering measurement of diagnostic x-ray spectrum using high-resolution Schottky CdTe detector
- DOI:10.1118/1.1921647
- 发表时间:2005-06-01
- 期刊:
- 影响因子:3.8
- 作者:Maeda, K;Matsumoto, M;Taniguchi, A
- 通讯作者:Taniguchi, A
Real-time estimation system for mean glandular dose in mammography
乳腺X线摄影平均腺体剂量实时估计系统
- DOI:
- 发表时间:2003
- 期刊:
- 影响因子:0
- 作者:M.Matsumoto;S.Inoue;I.Honda;S.Yamamoto;T.Ueguchi;Y.Ogata;T.Jokoh
- 通讯作者:T.Jokoh
X-ray spectrum of CT system acquired by Compton spectroscopy using high resolution Schottky CdTe detector
使用高分辨率肖特基 CdTe 探测器通过康普顿光谱获取 CT 系统的 X 射线光谱
- DOI:
- 发表时间:2005
- 期刊:
- 影响因子:0
- 作者:K.Maeda;M.Matsumoto
- 通讯作者:M.Matsumoto
Mammographic x-ray spectra measured by Compton spectroscopy using a high resolution Schottky CdTe detector
使用高分辨率肖特基 CdTe 探测器通过康普顿光谱测量乳房 X 射线光谱
- DOI:
- 发表时间:2004
- 期刊:
- 影响因子:0
- 作者:K.Maeda;M.Matsumoto
- 通讯作者:M.Matsumoto
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
MATSUMOTO Masao其他文献
MATSUMOTO Masao的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('MATSUMOTO Masao', 18)}}的其他基金
Development of quality control system of computed tomographic X-ray unit to decrease patient dose in diagnosis
开发计算机断层X射线机质量控制系统以减少患者诊断剂量
- 批准号:
12557223 - 财政年份:2000
- 资助金额:
$ 2.24万 - 项目类别:
Grant-in-Aid for Scientific Research (B)
Development of quaity control system of mammographic X-ray unit to decrease patiant dose in mammography
开发乳腺X线摄影机质量控制系统以减少乳腺X线摄影中患者的剂量
- 批准号:
11672242 - 财政年份:1999
- 资助金额:
$ 2.24万 - 项目类别:
Grant-in-Aid for Scientific Research (C)
Study of measuring system of x-ray spectrum for reduction of patient dose at medical x-ray diagnosis.
医学X射线诊断中降低患者剂量的X射线能谱测量系统研究
- 批准号:
08672583 - 财政年份:1996
- 资助金额:
$ 2.24万 - 项目类别:
Grant-in-Aid for Scientific Research (C)
The Comparative Study of the Gegel's and Fichte's Concept-Theory
格格尔与费希特概念理论的比较研究
- 批准号:
03610002 - 财政年份:1991
- 资助金额:
$ 2.24万 - 项目类别:
Grant-in-Aid for General Scientific Research (C)