Development of quaity control system of mammographic X-ray unit to decrease patiant dose in mammography
Development of quaity control system of mammographic X-ray unit to decrease patiant dose in mammography
批准号:
11672242
负责人:
MATSUMOTO Masao
金额:
$1.98万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
1999
资助国家:
日本
项目状态:
已结题
起止时间:
1999 至 2000
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Our purpose is to directly measure mammographic x-ray spectra with collimators and a low-efficiency CdZnTe detector developed recently and to find out the best fit response function of CdZnTe detector to correct the measured spectra. Photon spectra (target Mo or Rh) produced by a mammographic x-ray unit at 25-32 kV and 240 mAs (=3 times of 80 mAs) and transmitted through 0.03 mm Mo or 0.025 mm Rh filter and object (0.1 mm Al to 0.8 mm Al phantoms) have been analyzed. Since detected spectra were distorted by the response of CdZnTe detector and did not present the true photon spectra, the correction was applied by the stripping procedure. The response function of detector used in this procedure has been determined by the evaluation of interactions (K-escape, coherent scattering, and Compton scattering processes) and incomplete charge collection calculated using the Monte Carlo method. We have used K_<α1>, K_<α2>, K_<β1>, K_<β2> radiations of Cd, Zn, and Te, respectively and have used the weight function for the incomplete charge collection and have considered Compton scattering. The Monte Carlo simulations were continued by changing the important factors (mean path length of hole λ_h, dead layer of the CZT crystal and weight factor W_q) of incomplete charge collection until the best fit response function was found out. Corrected photon spectra were compared with the mammographic x-ray spectral data of Bureau of Radiological Health (BRH) measured using a Ge detector. Attenuation curves of aluminum for 25-32 kV were calculated from the corrected photon spectra and compared with the attenuation curves measured using an ionization chamber. These results obtained using the CdZnTe detector agreed with the mammographic x-ray spectral data of BRH and attenuation curves obtained by the ionization chamber.
期刊论文(22)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
S.MIYASIMA, S.MORIMI, M.MATSUMOTO et al.: "Correction for x-ray spectra measured with the CdZnTe detecter (Japanese)"J.S.Med.Imag.Into.Scie.. Vol.16-2. 79-89 (1999)
S.MIYASIMA、S.MORIMI、M.MATSUMOTO 等人:“用 CdZnTe 探测器测量的 X 射线光谱的校正(日语)”J.S.Med.Imag.Into.Scie.. Vol.16-2。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
A.Yamamoto, M.Matsumoto, et.al.: "Analysis of subject contrasts on mammographic X-ray units measured with a CdZnTe detector (Japanese)"J.S.Med.Imag.Inf.Scie.. Vol.17-3. 130-137 (2000)
A.Yamamoto、M.Matsumoto 等人:“使用 CdZnTe 探测器测量的乳房 X 射线单位的受试者对比度分析(日语)”J.S.Med.Imag.Inf.Scie.. Vol.17-3。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
宮島悟史,森見左近,松本政雄 他1名: "CdZnTe半導体検出器を用いて測定した診断用領域X線スペクトルの補正"医用画像情報学会雑誌. 16. 79-89 (1999)
Satoshi Miyajima、Sakon Morimi、Masao Matsumoto 和其他 1 人:“使用 CdZnTe 半导体探测器测量的诊断区域 X 射线光谱的校正”医学影像和信息科学学会杂志 16. 79-89 (1999)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
H.Arimura,T.Data,M.Matsumoto,他3名: "Influence of the scattered X-rays on object sharpness of radiograph"Proceedings of SPIE. 3977. 506-513 (2000)
H.Arimura、T.Data、M.Matsumoto 和其他 3 人:“散射 X 射线对射线照片物体清晰度的影响”SPIE 论文集 3977. 506-513 (2000)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
松本政雄,稲邑清也: "フラットパネルディテクタの物理特性について"医学物理. 20・Supp.No.1. 17-42 (2000)
Masao Matsumoto、Kiyoya Inamura:“平板探测器的物理特性”医学物理学 20·Supp.No.1 (2000)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 22 条
DEVELOPMENT OF QUALITY CONTROL SYSTEM FOR DIAGNOSTIC X-RAY UNITS TO AIM REDUCTION OF PATIENT DOSE
-
批准号:15590458
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.24万
-
财政年份:2003
-
负责人:MATSUMOTO Masao
-
依托单位:
Development of quality control system of computed tomographic X-ray unit to decrease patient dose in diagnosis
-
批准号:12557223
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$4.1万
-
财政年份:2000
-
负责人:MATSUMOTO Masao
-
依托单位:
Study of measuring system of x-ray spectrum for reduction of patient dose at medical x-ray diagnosis.
-
批准号:08672583
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.47万
-
财政年份:1996
-
负责人:MATSUMOTO Masao
-
依托单位:
The Comparative Study of the Gegel's and Fichte's Concept-Theory
-
批准号:03610002
-
项目类别:Grant-in-Aid for General Scientific Research (C)
-
资助金额:$0.77万
-
财政年份:1991
-
负责人:MATSUMOTO Masao
-
依托单位:
海外基金