课题基金 / 基金详情

Study on High Luminous Efficacy and Long Lifetime Cluster Light Source.

Study on High Luminous Efficacy and Long Lifetime Cluster Light Source.
高光效长寿命集群光源的研究。
批准号:
16560241
负责人:
SEKINE Seishi
金额:
$2.37万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2004
资助国家:
日本
项目状态:
已结题
起止时间:
2004 至 2005

项目摘要

项目成果

SEKINE Seishi的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
1. Experimental research1) We verified that WO_2 and MoO_3 and Re_2O_7 are suitable to make cluster, support material which is optimum for forming the tungsten cluster is NaBr, and NeAr mixed gas is suitable for the electric discharge gas and the filling pressure of 21.3 KPa is optimum.2) Using MoO_3 which does not require the support material in the cluster material, we examined how luminescence property of the cluster differs by type of the electric discharge gas. As a result, we obtained the knowledge that the luminous flux of NeAr, Kr, Ar and Xe was high in order.3) As a result of examining the metals suitable for formation of the cluster, it was 2 types of molybdenum and rhenium that these cluster emitted light without the halogen which assists the formation of the cluster.2. Theoretical researchComplex index of refraction of the cluster in operating temperatures of 4000 K - 5000 K is necessary in order to theoretically estimate luminescence property of the cluster light sources. In 2004 fiscal year, we measured the complex index of refraction of the bulk tungsten using the ellipsometry equipment which we have constructed. We calculated the complex index of refraction of the tungsten filaments of chandeliers lamps and halogen lamps which emitted light at the operating temperatures of 2000 K - 3000 K by the ellipsometry. The laser beam of the wavelength of 532nm which was second harmonic of the Nd : YAG laser of the wavelength of 1064nm in light source of the ellipsometry was used. As a result of comparing the complex index of refraction calculated by the ellipsometry with the value of the literature, the calculated complex index of refraction verified being a accuracy in which real part and imaginary part are high both.
期刊论文(24)
专著(0)
科研奖励(0)
会议论文
Evaluation of Tungsten Cluster Radiation Dependent on Various Metal Harides.
各种金属卤化物对钨簇辐射的评估。
DOI: --
发表时间: 2004
期刊: J.Illum.Engng.Inst.Jpn. Vol.88, No.5
影响因子: --
作者: [Ayumu Sato, Kazuyuki Hosaka, Hiroki Kubo, Seishi Sekine, Masashi Ohkawa]
通讯作者: Masashi Ohkawa
Evaluation of Complex Refractive Index of Metal Clusters by Scattering Ellipsometry
散射椭圆光度法评价金属团簇的复折射率
DOI: --
发表时间: 2005
期刊: 電気学会論文誌A 127・5
影响因子: --
作者: [Ayumu.Sato, Yasunari Harada Seishi Sekine, Masashi Ohkawa]
通讯作者: Masashi Ohkawa
Measurement of Complex Refractive Index of Tungsten by Using Ellipsometry.
使用椭圆光度法测量钨的复折射率。
DOI: --
发表时间: 2005
期刊: Journal of Light & Visual Environment Vol.29, No.3
影响因子: --
作者: [Ayumu SATO, Seishi EKINE, Masashi OHKAWA]
通讯作者: Masashi OHKAWA
DOI: --
发表时间: 2004
期刊: 照明学会誌 88・5
影响因子: --
作者: [佐藤 歩, 保坂和幸, 久保博樹, 関根征士, 大河正志]
通讯作者: 大河正志
6
    Study on incandescent microcavity radiator of high luminous efficacy by reduction of infrared radiation
    • 批准号:
      12650270
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $2.37万
    • 财政年份:
      2000
    • 负责人:
      SEKINE Seishi
    • 依托单位: