A Study of Body Temperature Measurement Using the Zero-Heat-Flow Technique
A Study of Body Temperature Measurement Using the Zero-Heat-Flow Technique
批准号:
62550300
负责人:
TOGAWA Tatsuo
金额:
$1.15万
依托单位国家:
日本
项目类别:
Grant-in-Aid for General Scientific Research (C)
财政年份:
1987
资助国家:
日本
项目状态:
已结题
起止时间:
1987 至 1988
中文摘要
点击翻译按钮获取中文摘要
英文摘要
The deep body thermometer is an instrument for body temperature monitoring in which zero-heat-flow technique is employed. It was invented by Fox in 1971. improved by one of the investigator of this project (T.T.). and now spreading for post operative patient monitoring and many other applications. However. its ultimate accuracy has not been well studied. The project was planned to investigate the accuracy of the deep body thermometer. and also to provide a modification of the probe design. which is critical to the accuracy.The probe of the deep body thermometer was modified so that a slight positive feedback control was introduced to compensate the error due to a heat flow from the deep tissue to the ambient air detouring the probe. The performance of the probe was examined by 1) numerical analysis. 2) simulator experiment. and 3) measurements in volunteer subjects.As the results. it was shown by the numerical analysis and the simulator experiment that the modification in the probe design significantly reduces the measurement error. The subject study showed that the averaged differences between measured body temperatures by the modified probe and a sublingual thermistor probe remained within 0.1゜C in a room temperature of 20゜C and 25゜C.From these results. it was confirmed that the modification in the probe design could realize accuracy which satisfies most demands of clinical body temperature measurements.
期刊论文(5)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Togawa.T.: "Encyclopedia of Medical Devices and Instrumentations.Webster.J.G.ed." John Wiley & Sons, 2765-2770 (1988)
Tokawa.T.:“医疗器械和仪器百科全书。Webster.J.G.ed。”John Wiley & Sons,2765-2770 (1988)
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
戸川達男: BME. 2. 156-160 (1988)
十川龙夫:BME。2. 156-160 (1988)
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
戸川達男: 小児看護. 10. 1163-1167 (1987)
十川龙夫:儿科护理。10. 1163-1167 (1987)
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Togawa, T.: "Clinical thermometers" Jap. J. Child Nurs.10. 1163-1167 (1987)
Tokawa, T.:“临床温度计”日本。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Research on monitoring of physical and mental reserve capacities at home
-
批准号:16300163
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$4.42万
-
财政年份:2004
-
负责人:TOGAWA Tatsuo
-
依托单位:
Sweat measurement technique using the electrical conductivity method applicale for QSART
-
批准号:12480259
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$2.75万
-
财政年份:2000
-
负责人:TOGAWA Tatsuo
-
依托单位:
Development of health monitoring system at home
-
批准号:12558104
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$6.27万
-
财政年份:2000
-
负责人:TOGAWA Tatsuo
-
依托单位:
A study on imaging of thermal properties of the skin
-
批准号:09480251
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$5.57万
-
财政年份:1997
-
负责人:TOGAWA Tatsuo
-
依托单位:
Optical fiber sensor with optical power feed
-
批准号:08044255
-
项目类别:Grant-in-Aid for international Scientific Research
-
资助金额:$2.82万
-
财政年份:1996
-
负责人:TOGAWA Tatsuo
-
依托单位:
Fiber optic power-feed system for biomedical application
-
批准号:02452178
-
项目类别:Grant-in-Aid for General Scientific Research (B)
-
资助金额:$3.52万
-
财政年份:1990
-
负责人:TOGAWA Tatsuo
-
依托单位:
Development of Biomedical Transducer by Use of Optical Fiber Sensor and Actuator
-
批准号:63044037
-
项目类别:Grant-in-Aid for international Scientific Research
-
资助金额:$3.65万
-
财政年份:1988
-
负责人:TOGAWA Tatsuo
-
依托单位:
Development of Ambulatory Oxygen Uptake Measurement System
-
批准号:63870009
-
项目类别:Grant-in-Aid for Developmental Scientific Research (B).
-
资助金额:$4.03万
-
财政年份:1988
-
负责人:TOGAWA Tatsuo
-
依托单位: