Development of a radiological method for the measurement of bone mineral content in bone disease

Development of a radiological method for the measurement of bone mineral content in bone disease
开发用于测量骨病中骨矿物质含量的放射学方法
批准号:
62570891
负责人:
KATOH Tsuguhisa
金额:
$1.15万
依托单位国家:
日本
项目类别:
Grant-in-Aid for General Scientific Research (C)
财政年份:
1987
资助国家:
日本
项目状态:
已结题
起止时间:
1987 至 1988

项目摘要

项目成果

KATOH Tsuguhisa的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
1. High speed image processing system using a digital image scanner Using a digital image scanner (Sharp JX450) interfaced throygh GPIB to an personal computer (Fijitsu FM11), an X-ray image could be read within 2 minutes. The characteristics of this image input system was estimated as follows. 1) Effective pixel size was 0.143mm. 2) To measure the film density, the logalithm of the output gray level should be taken. 3) The maximum measurable film density was 1.5. 4) The efective precission of the quiantamized gray level was 64. The crude performance of this system was, therefore, insufficient for the input device for the quantitative analysis. To compensate them, the soft ware system was modified and the beam quallty of the x-rays was hardened. Then the dynamic range to the object thickness became comparable to that of the michro-denditometer system. In order to improve the image processing speed, a floating point processior boad was added. The driving soft ware is on the development. 2. Observation of the growing process of new bone arround of the implanted hydroxyapatite The growing process of new bone arround of the implanted hydroxyapatite was observed from one month to one year by the hisological method and the present method. The new bone began to be calcified at one month after the implant, and grew to surround the apatite rod at three months after the operation. At one year after, the new bone grew thick and be replaced by matured lamelar bone. The observation by the present method gave the similar result to the histological observation. The bone mineral was not detected after one month. 0.3g/cm2 bone mineral was measured at three months after the operation. The mineral content did not varied to one year after the implant. 3 Summary The present mathod enable the indistructive observation of the change in the bone mineral content. In the present, only the thin object could be observed. We are planning to improve the system to observe the thicker objects.
期刊论文(6)
专著(0)
科研奖励(0)
会议论文
Tsuguhisa, Katoh: "Characteristics of a digital image reader (Sharp JX450) as an input device of radiographec images" Dent. Radiol.
Tsuguhisa, Katoh:“数字图像读取器 (Sharp JX450) 作为射线照相图像输入设备的特性” Dent。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
加藤二久: 歯科放射線.
加藤富久:牙科放射学。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Tsuguhisa,Katoh.: 日本医学放射線学会誌.
Tsuguhisa, Katoh.:日本医学放射学会杂志。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Tsuguhisa Katoh: 日医放誌.
加藤继久:日井法师。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Quality Assurance Supporting System for Digital X-ray Image Utilizing Filing System of DICOM-3.0
Development of Radiological Diagnostic Information System for Dental Practice Based on DICOM-3.0
Development of Radiological Information System for Dentistry Based on DOCOM-3.0
  • 批准号:
    08672151
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $1.47万
  • 财政年份:
    1996
  • 负责人:
    KATOH Tsuguhisa
  • 依托单位:
The application of dual energy subtraction technique to sialography
  • 批准号:
    02670890
  • 项目类别:
    Grant-in-Aid for General Scientific Research (C)
  • 资助金额:
    $1.34万
  • 财政年份:
    1990
  • 负责人:
    KATOH Tsuguhisa
  • 依托单位:
海外基金