课题基金 / 基金详情

Development and clinical use of measurement system of mandibular bone density without using X-ray

Development and clinical use of measurement system of mandibular bone density without using X-ray
非X线下颌骨骨密度测量系统的研制及临床应用
批准号:
07557284
负责人:
SATO Koshi
金额:
$0.96万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (A)
财政年份:
1995
资助国家:
日本
项目状态:
已结题
起止时间:
1995 至 1996

项目摘要

项目成果

SATO Koshi的其他基金

相似基金

相关文献

中文摘要
翻译
骨振动分析系统用于骨质疏松症筛查的研究目的。本研究的目的是将该系统应用于下颌骨,制作不使用x线的下颌骨骨密度测量系统,并检验其临床应用的可能性。下颌骨的振动是通过把下巴放在拾取传感器上,然后用锤子自动敲击额头的过程产生的。将恒频(fc)转换为骨硬度,预测下颌骨的成熟度和内部结构。由手持式FFT分析仪和个人计算机自动完成数据采集、频率分析和fc计算。评价身高、体重、骨密度值、下颌骨形状等生长指标与下颌骨fc的关系。结果表明:1)fc与身高、体重关系不显著。2) fc与腕骨骨密度呈显著相关。3)下颌骨的大小,特别是支高度、前牙槽高度和联合厚度根据头侧测量显示出显著性。4)在骨骼III类和短脸处,fc表现出较高的趋势。结果表明,该系统测量的参数可作为评价下颌骨形状和质量的新指标。这将为骨成熟度评价、生长潜力预测指标、正畸手术愈合程序、牙齿运动锚定价值在正畸治疗中的应用提供依据。
英文摘要
The vibration analyzing system of the bone is used for the research purpose of screening osteoporosis. The purpose of this study was to apply this system to the mandible and fabricate the measurement system of mandibular bone density without using X-ray and check its possibility for the clinical use.Vibration of the mandible was produced through the procedures of setting the chin on the pick up sensor and hit the forehead by the hammer antomatically. The constant frequency (fc) was converted as a hardness of the bone, and the maturity and inner structures of the mandible were predicted. The data taking, frequency analysis and the calculation of the fc were automatically carried out by the hand-held FFT analyzer and the personal computer. The relationship between the growth indicators such as a body height, body weight, value of bone mineral density and the shape of the mandible, etc.and the fc of the mandible were evaluated.The results were as follows :1)The fc did not show the significant relationship with a body height and weight.2)The significant relationship was found between the fc and bone mineral density of the wrist bone.3)The size of the mandible, especially the ramus height, anterior alveolar height and the thickness of the symphysis showed the significance according to the cephalometric evaluation.4)The fc demonstrated the tendency that was higher at the Skeletal Class III and a short face.The results suggest that the parameters measured by this system might be used as the new indicators to evaluate the shape of the mandible and quality of the mandibular bone. This would lead the applications such as the evaluation of bone maturity, the indicators to predict the growth potentiality, healing procedure through the orthognathic surgery, the anchorage value for the teeth movement in orthodontic treatment.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Effects on the growth of children in disaster area by the GreatEast Japan Earthquake
  • 批准号:
    23890017
  • 项目类别:
    Grant-in-Aid for Research Activity Start-up
  • 资助金额:
    $2.08万
  • 财政年份:
    2011
  • 负责人:
    SATO Koshi
  • 依托单位:
Protective Effects of Urinary Trypsin Inhibitor(UTI) on Hepatic Microvasculature in Hypotensive Brain-Dead Rats
  • 批准号:
    12671172
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $2.11万
  • 财政年份:
    2000
  • 负责人:
    SATO Koshi
  • 依托单位:
Establishment of Cervical Vertebral Bone Age Based on Pattern Matching Method
  • 批准号:
    10671924
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $2.11万
  • 财政年份:
    1998
  • 负责人:
    SATO Koshi
  • 依托单位:
Hepatic denervation : Hemodynamic changes
  • 批准号:
    06671224
  • 项目类别:
    Grant-in-Aid for General Scientific Research (C)
  • 资助金额:
    $1.34万
  • 财政年份:
    1994
  • 负责人:
    SATO Koshi
  • 依托单位:
海外基金