The development of the portable x-ray equipment for dentistry.
The development of the portable x-ray equipment for dentistry.
批准号:
09671930
负责人:
SUZUKI Yosuke
金额:
$2.11万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
1997
资助国家:
日本
项目状态:
已结题
起止时间:
1997 至 1999
中文摘要
本研究的目的是建立一种安全、实用的家庭牙科X线检查方法。为了减少患者、牙医和辅助人员的剂量,研制了一种便携式X射线设备,该设备使用X射线CCD传感器。采用透明防护材料KYOWAGLAS-XA研制了便携式X射线机照射锥防护罩。它可以从病人的散射X射线阴影。将照射锥更换为透明材料,使X线投照定位容易、安全。研制了X射线CCD传感器的保持装置。它由两个可伸缩的臂和安装装置组装而成。使用该夹持装置,可以在不需要任何辅助人员的情况下,准确、安全地进行X线检查。使用该便携式X射线设备,在距离患者1 m处,牙科医生的最大剂量为3.12μSv/sec(0.936μSv/次检查)。按15000个齿距病人20 cm照射计算,牙医年最大剂量估计为6.75mSv。协助人员或家属在防护罩后50次照射,距患者1 m处年最大剂量为0.9μSv。作为一个未来的主题,似乎减少X射线头的重量是必要的便携性。
英文摘要
The purpose of this research is to establish an X-ray examination which is safe and useful for the home dental treatment. A portable X-ray equipment was developed in order to reduce the dose of patients, dentists and assistant persons using a X-ray CCD sensor. A protection shade attached to the irradiation cone of the portable X-ray equipment was developed with clear protection material such as KYOWAGLAS-XA. It could shade from the scattered X-rays of the patient. The irradiation cone was changed to a clear material one so that the positioning of X-ray projection was accomplished easily and safely. A hold device of the X-ray CCD sensor was also developed. It was assembled with two extensible arms and mounting devices. Using this hold device, the X-ray examination could be performed accurately and safely without any dose of assistant person . The maximum dose of dentist was 3.12μSv/sec (0.936μSv/examination) at the distance of 1m from the patient using this portable X-ray equipment. The maximum estimated dose of dentist was 6.75mSv a year by the exposure of 15, 000 tines at the distance of 20cm from the patient. The maximum dose of assistant person or family was 0.9μSv at the distance of 1 m from patient a year by the exposure of 50 times behind the protection shade. As a future subject it seemed that the reduction of the weight of the X-ray head is necessary for the portability.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Yosuke SUZUKI, Nobue MATSUMOTO ,Hiroshi MORITA and Hiromitsu OHKAWA: "The Influence of the Oblique Incident X-ray that Affected the Image Quality of the X-ray CCD sensor"Ohu University Dental Journal. 25. 394-355 (1998)
Yosuke SUZUKI、Nobue MATSUMOTO、Hiroshi MORITA 和 Hiromitsu OHKAWA:“倾斜入射 X 射线对 X 射线 CCD 传感器图像质量的影响”Ohu 大学牙科杂志。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Development of modular robot system generating locomotion and control function in an identical structure
-
批准号:22860025
-
项目类别:Grant-in-Aid for Research Activity Start-up
-
资助金额:$1.91万
-
财政年份:2010
-
负责人:SUZUKI Yosuke
-
依托单位:
Digital X-ray equipment with double arms for handicapped person.
-
批准号:17591972
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.17万
-
财政年份:2005
-
负责人:SUZUKI Yosuke
-
依托单位:
Changes in the expression of adenylyl cyclase and G-protein mRNA and the regulation system in myometrium
-
批准号:11671639
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.18万
-
财政年份:1999
-
负责人:SUZUKI Yosuke
-
依托单位:
海外基金