DEVELOPMENT OF A SPATIAL LIMITED ANGLE MODEL FOR COMPUTERIZED X RAY TOMOGRAPHY
计算机X射线断层摄影空间有限角度模型的开发
基本信息
- 批准号:6240031
- 负责人:
- 金额:$ 10.83万
- 依托单位:
- 依托单位国家:美国
- 项目类别:
- 财政年份:1997
- 资助国家:美国
- 起止时间:1997-07-01 至 1998-06-30
- 项目状态:已结题
- 来源:
- 关键词:
项目摘要
Our research proposal deals with the development of a highly
parallelizable, spatial, limited angle model for computerized X-ray and
electron tomography, capable to perform spatial reconstructions in real
time. This model is based upon a continuous extension of the Radon
transform on vector spaces over finite fields. The limited angle
feature of this model is specially important in three-dimensional
imaging with transmission electron microscopes where the tilting angle
is limited to +/-60 degrees. It is also important in the design of
scanning devices for X-ray tomography since it.would permit to
eliminate the tunnel shape of current scanners.
The first phase of the proposed research, regarding X-ray tomography,
is two-fold. First, following previous findings, we shall complete the
study by determining the geometry that yields minimum noise, and
accordingly, we shall adjust the algorithms for simulating how the
model works in the spatial case, under sequential and parallel
programming.
Secondly, a comparative study of the quality of the reconstructions and
speed will be performed, taking into consideration other existing
models.
The second phase consist of a new specific aim of this project related
to electron tomography, namely, to apply a modification of our
algorithm to data collected by using transmission electron microscopy,
following a recent technique developed by P. Schwander (AT&T Bell
Labs.) to determine the atomic structure of crystals. Schwander's
methods have open a new field which could be named Discrete Binary
Tomography, in which our algorithms seem to work well. Indeed, in case
that the crystal consists of one type of atom, a crystal can be model
as a three dimensional array only of 0's and 1's of which it is
possible to measure projection only in two to four directions along
certain zone axes. Therefore, the heuristic consists in applying our
reconstruction transform to the available projections obtaining a 3-dim
array of values. Each of these values, measured on a scale from 0.0 to
1.0, gives the likelihood of the presence of an atom in that position.
Some preliminary algorithms developed following this heuristic are
yielding promising reconstructions.
An important goal of this project is to attract two outstanding
graduate minority students majoring in mathematics or in computer
sciences, to biomedical research. For at least three years these
students will receive personalized training in the mathematics of
tomography, will be encouraged to pursue doctoral studies in bio-
mathematics, and will be on charge of most of the computational
development and implementation of the model.
The long-term objectives of this proposal are to create a multi-
disciplinary environment, involving graduate minority students,
mathematicians, computer scientists, engineers and physicists, aimed
at producing biomedical research in the various aspects of tomography,
such as a prototype X-ray CT scanner based on our spatial model.
我们的研究计划涉及一种高度
项目成果
期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
PABLO SALZBERG其他文献
PABLO SALZBERG的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('PABLO SALZBERG', 18)}}的其他基金
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6609861 - 财政年份:2002
- 资助金额:
$ 10.83万 - 项目类别:
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6601185 - 财政年份:2002
- 资助金额:
$ 10.83万 - 项目类别:
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6631252 - 财政年份:2002
- 资助金额:
$ 10.83万 - 项目类别:
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6564513 - 财政年份:2002
- 资助金额:
$ 10.83万 - 项目类别:
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6472789 - 财政年份:2001
- 资助金额:
$ 10.83万 - 项目类别:
3D TOMOGRAPHY MODELS IN ELECTRON MICROSCOPY OF CRYSTALS
晶体电子显微镜中的 3D 断层扫描模型
- 批准号:
6325852 - 财政年份:2000
- 资助金额:
$ 10.83万 - 项目类别:
DEVELOPMENT OF A SPATIAL LIMITED ANGLE MODEL FOR COMPUTERIZED X RAY TOMOGRAPHY
计算机X射线断层摄影空间有限角度模型的开发
- 批准号:
6219062 - 财政年份:1999
- 资助金额:
$ 10.83万 - 项目类别:
DEVELOPMENT OF A SPATIAL LIMITED ANGLE MODEL FOR COMPUTERIZED X RAY TOMOGRAPHY
计算机X射线断层摄影空间有限角度模型的开发
- 批准号:
6107140 - 财政年份:1998
- 资助金额:
$ 10.83万 - 项目类别:
DEVELOPMENT OF A SPATIAL LIMITED ANGLE MODEL FOR COMPUTERIZED X RAY TOMOGRAPHY
计算机X射线断层摄影空间有限角度模型的开发
- 批准号:
6271553 - 财政年份:1998
- 资助金额:
$ 10.83万 - 项目类别:
DEVELOPMENT OF A SPATIAL LIMITED ANGLE MODEL FOR COMPUTERIZED X RAY TOMOGRAPHY
计算机X射线断层摄影空间有限角度模型的开发
- 批准号:
3734280 - 财政年份:
- 资助金额:
$ 10.83万 - 项目类别: