AIRWAY IMAGING BY ACOUSTIC REFLECTION

通过声反射进行气道成像

基本信息

  • 批准号:
    2224458
  • 负责人:
  • 金额:
    $ 25.67万
  • 依托单位:
  • 依托单位国家:
    美国
  • 项目类别:
  • 财政年份:
    1993
  • 资助国家:
    美国
  • 起止时间:
    1993-09-15 至 1995-08-31
  • 项目状态:
    已结题

项目摘要

This Phase II application deals with non-invasive acoustic imaging of the nasal airway. Images of airway cross sectional area as a function of axial distance along the airway are reconstructed from amplitudes and arrival times of acoustic returns measured at the airway opening. Although this technology has been shown to be accurate, to require little or no subject cooperation and to have a number of diagnostic applications in nasal, pharyngeal and pulmonary airways, its broader applicability has been limited by unwieldy dimensions of the apparatus, which have hindered its use outside the research laboratory. In Phase I we developed a new theoretical approach that releases the acoustical constraint that had previously set the minimum possible length of the apparatus. Accordingly, this theory revealed a pathway for developing a compact apparatus. Unlike single-microphone systems used currently, this new technology is based upon a two-microphone measurement. In Phase I we successfully developed, implemented and validated this theory, associated algorithms and a prototype apparatus. Compared with present single-microphone systems this prototype was smaller by more than an order of magnitude and exhibited substantially improved measurement stability and ease of use. The objective of this Phase II application is to refine and package this next generation of acoustic reflection technology, as well as to explore and validate its clinical utility. The technology developed in Phase II will find diagnostic and screening applications not only in the research laboratory, but also in the doctor's office, in the ICU and in the workplace. Because it requires little contact time and little or no subject cooperation, this technology might become particularly useful in the pediatric clinic and the neonatal ICU.
这个第二阶段的应用处理的是非侵入性声学成像

项目成果

期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ monograph.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ sciAawards.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ conferencePapers.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ patent.updateTime }}

GARY M GLASS其他文献

GARY M GLASS的其他文献

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

{{ truncateString('GARY M GLASS', 18)}}的其他基金

AIRWAY AREA BY ACOUSTIC REFLECTOMETRY
通过声学反射法测定气道面积
  • 批准号:
    2233677
  • 财政年份:
    1996
  • 资助金额:
    $ 25.67万
  • 项目类别:
AIRWAY AREA BY ACOUSTIC REFLECTOMETRY
通过声学反射法测定气道面积
  • 批准号:
    2771458
  • 财政年份:
    1996
  • 资助金额:
    $ 25.67万
  • 项目类别:
AIRWAY AREA BY ACOUSTIC REFLECTOMETRY
通过声学反射法测定气道面积
  • 批准号:
    2435966
  • 财政年份:
    1996
  • 资助金额:
    $ 25.67万
  • 项目类别:
AIRWAY IMAGING BY ACOUSTIC REFLECTION
通过声反射进行气道成像
  • 批准号:
    2224459
  • 财政年份:
    1993
  • 资助金额:
    $ 25.67万
  • 项目类别:
AIRWAY IMAGING BY ACOUSTIC REFLECTION
通过声反射进行气道成像
  • 批准号:
    3502211
  • 财政年份:
    1992
  • 资助金额:
    $ 25.67万
  • 项目类别:
{{ showInfoDetail.title }}

作者:{{ showInfoDetail.author }}

知道了