Low dose digital X-rays for mammographic screening
Low dose digital X-rays for mammographic screening
批准号:
6969193
负责人:
CHRISTOPHER L VAUGHAN
金额:
$11.88万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2005
资助国家:
美国
项目状态:
已结题
起止时间:
2005-09-01 至 2007-08-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant):
Breast cancer currently accounts for 9% of all cancers worldwide, while in the United States 32% of cancer incidence and 18% of cancer deaths are a result of breast carcinoma. Although recent reports in the popular media have called into question the benefits of mammographic screening, the scientific literature is clear: early detection and treatment of breast cancer have yielded a 20% reduction in the mortality rate in the past decade. Despite the success of current screen-film mammography systems, which account for more than 95% of all units worldwide, they do suffer from a number of drawbacks. The long-term objective of this project is to address these drawbacks by developing a digital mammography system built on innovative medical imaging technologies that have been created in South Africa. Specifically, our aim is to develop a system with the following important features: (1) significantly lower radiation exposure for both patients and healthcare workers; (2) outstanding image quality verified by modulation transfer function (MTF) and detective quantum efficiency (DQE); (3) improved patient comfort through the reduction of painful breast compression; (4) greater coverage of breast anatomy, resulting in fewer missed diagnoses; (5) the provision of computer-assisted diagnosis (CAD) based on the digital images; and (6) reduced time spent in the exam room, leading to increased patient throughput. There will be two overlapping phases to the project. In phase 1, a prototype digital mammography system will be designed, built and tested. We will reduce radiation exposure while maintaining image quality by incorporating a patented slot scanning technique that has recently been approved for whole-body trauma applications by the Food and Drug Administration. Solid-state image sensors will be incorporated in the design of the X-ray detectors, maximizing the signal-to-noise ratio. A careful study of MTF and DQE will be conducted, in addition to manikin phantom studies to measure dose and detection of small lesions. By scanning in a motion that accounts for breast anatomy, it will be possible to improve patient comfort by reducing the need for breast compression and also covering a greater volume of breast tissue. Because the images will be in digital form, this will facilitate CAD applications while also reducing patient examination time. During the last 6 months of the project in phase 2, we will conduct a limited clinical trial of 20 patients, focusing on comfort, breast coverage and diagnostic equivalence.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Low dose digital X-rays for mammographic screening
-
批准号:7140094
-
项目类别:
-
资助金额:$11.6万
-
财政年份:2005
-
负责人:CHRISTOPHER L VAUGHAN
-
依托单位:
ANKLE FOOT ORTHOSES FOR MANAGEMENT OF SPASTIC DIPLEGIA
-
批准号:3331475
-
项目类别:
-
资助金额:$13.35万
-
财政年份:1992
-
负责人:CHRISTOPHER L VAUGHAN
-
依托单位:
ANKLE FOOT ORTHOSES FOR MANAGEMENT OF SPASTIC DIPLEGIA
-
批准号:3331476
-
项目类别:
-
资助金额:$13.02万
-
财政年份:1992
-
负责人:CHRISTOPHER L VAUGHAN
-
依托单位:
ANKLE FOOT ORTHOSES FOR MANAGEMENT OF SPASTIC DIPLEGIA
-
批准号:2202473
-
项目类别:
-
资助金额:$13.44万
-
财政年份:1992
-
负责人:CHRISTOPHER L VAUGHAN
-
依托单位:
海外基金