Annual ReportsBreastFatty acid glycerol estersFocused Ultrasound TherapyFrequenciesFundingGoalsGrantHumanImageImageryLocationMagnetic ResonanceMagnetic Resonance ImagingMammary Gland ParenchymaMapsMethodsNational Center for Research ResourcesPrincipal InvestigatorProtonsReadingResearchResearch InfrastructureResourcesScanningSignal TransductionSonicationSourceSpottingsStagingSystemTechnologyTestingThermometryTimeUltrasonographyUnited States National Institutes of HealthVisitWeightabstractingbasecold temperaturecosttooltreatment center
中文摘要
点击翻译按钮获取中文摘要
英文摘要
This subproject is one of many research subprojects utilizing the resources
provided by a Center grant funded by NIH/NCRR. Primary support for the subproject
and the subproject's principal investigator may have been provided by other sources,
including other NIH sources. The Total Cost listed for the subproject likely
represents the estimated amount of Center infrastructure utilized by the subproject,
not direct funding provided by the NCRR grant to the subproject or subproject staff.
Introduction
During the planning stage of MRI-guided focused ultrasound treatments in breast, the actual location of the focus is
verified by visualization of a low temperature test spots using proton resonance frequency (PRF) thermometry. However, in
fat PRF becomes unreliable. The alternative approaches are based on T1-weighted imaging with fast spin-echo (FSE) [1]
and on displacement imaging with MR-ARFI. The goal of this study was to evaluate both methods in human ex vivo breast
tissue.
Methods
For six focal locations, imaging was performed with ultrasound, using MR-ARFI and FSE. For FSE, repetition time (TR) was
varied. Imaging was performed on a 3T MRI scanner equipped with a HIFU system, and timed such that the sonications
and the scans ended at the same time. SNR of the signal at the focus was analyzed using MR-ARFI displacement maps and
FSE magnitude difference images.