A Neonatal Cerebral Blood Flow Monitor based on MEMS Ultrasound
A Neonatal Cerebral Blood Flow Monitor based on MEMS Ultrasound
批准号:
8333910
负责人:
David Frederick Lemmerhirt
金额:
$20.01万
依托单位国家:
美国
项目类别:
财政年份:
2011
资助国家:
美国
项目状态:
已结题
起止时间:
2011-09-15 至 2014-08-31
关键词:
AddressAnatomyAnimalsBehavioralBlood flowBrainBrain InjuriesCaringCerebral PalsyCerebral hemisphere hemorrhageCerebrovascular CirculationCerebrumClinicalClinical ResearchCognitiveComputer softwareDataDevelopmentDevicesDoppler UltrasoundElderlyElementsEnsureEquipmentFrequenciesGoalsHeadHealthHealth Care CostsHealthcareHumanImageIncubatorsInfantInjuryLaboratoriesLegal patentLifeLocationManufacturer NameMarketingMeasurementMeasuresMethodsMichiganMonitorNeonatalNeonatal Brain InjuryOutcomePatientsPerformancePeripheral arterial diseasePhasePhysiciansPositioning AttributePremature InfantPrevalencePublic HealthReproducibilityResearch PersonnelSafetySchemeSocietiesSurvival RateSurvivorsSymptomsSystemTechniquesTechnologyTestingThinkingThree-Dimensional ImageTissuesTransducersTranslatingTubeUltrasonic TransducerUltrasonographyUniversitiesVery Low Birth Weight InfantWaterWorkbasebrain tissuedesignflexibilityimprovedinnovationlife time costmeetingsmonitoring devicenovelpatient populationportabilityprogramsprototyperesearch study
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): The goal of the proposed program is to address several technical feasibility questions (in Phase I), and then demonstrate (in a subsequent Phase II) a safe, compact patch-like monitoring device for directly measuring blood flow to the brain in very low birth weight (VLBW, <1500gm) infants. In Phase I, the accuracy of 3D Doppler techniques will be evaluated for the vessel sizes and geometries specific to the neonatal brain, and the feasibility will be determined for implementing these techniques using a compact MEMS-based ultrasound transducer module. In Phase II, a full-scale transducer prototype will be developed and demonstrated in animal and/or clinical studies. Finally, in Phase III the monitoring hardware and software will be commercialized and translated to the clinical market, likely in partnership with manufacturers of existing neonatal monitoring equipment. The clinical market stands to benefit greatly from this innovation, given that nearly 64,000 VLBW infants are born in the U.S. each year. Many of these fragile patients will sustain devastating brain injuries during the first days and weeks of life due to abnormal blood flow to the brain. Currently, brain injuries cause 5-10% of VLBW survivors to suffer from cerebral palsy and many more will develop cognitive or behavioral abnormalities in later life. Regular monitoring of blood flow to the neonatal brain would provide physicians the information needed to intervene early, reducing the likelihood of lasting injury. This would clearly have immense human benefit and would also reduce healthcare spending, given recent estimates that suggest the lifetime cost of care for each cerebral palsy patient will exceed $1M.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
An Instantaneous Ultrasonic Personal Blood Pressure Monitor
-
批准号:8936260
-
项目类别:
-
资助金额:$42.16万
-
财政年份:2015
-
负责人:David Frederick Lemmerhirt
-
依托单位:
A Neonatal Cerebral Blood Flow Monitor based on MEMS Ultrasound
-
批准号:8145972
-
项目类别:
-
资助金额:$24.69万
-
财政年份:2011
-
负责人:David Frederick Lemmerhirt
-
依托单位:
A Commercially-Viable MEMS-based Ultrasonic Volume Flow Sensor
-
批准号:8058361
-
项目类别:
-
资助金额:$18.7万
-
财政年份:2010
-
负责人:David Frederick Lemmerhirt
-
依托单位:
Commercially Viable Wide-Band Ultrasound Arrays Based on CMUT Technology
-
批准号:7746929
-
项目类别:
-
资助金额:$14.49万
-
财政年份:2009
-
负责人:David Frederick Lemmerhirt
-
依托单位:
海外基金