Tablet-Based Augmented Reality for Fast CT Guidance with Reduced Radiation
Tablet-Based Augmented Reality for Fast CT Guidance with Reduced Radiation
批准号:
9558675
负责人:
Pezhman Foroughi
金额:
$22.45万
依托单位国家:
美国
项目类别:
财政年份:
2018
资助国家:
美国
项目状态:
已结题
起止时间:
2018-04-03 至 2018-10-02
关键词:
AddressAdoptedAlgorithmsAugmented RealityClinicalComputer softwareComputersCost SavingsDataData CollectionDetectionEvolutionFeedbackFutureGoalsHead and Neck CancerIncidenceInterventionInterventional radiologyIonizing radiationMagnetic Resonance ImagingMeasurementMedicalMindMono-SNavigation SystemNeedle biopsy procedureOperating RoomsOutcomePatientsPerformancePhasePhysiciansProceduresProcessPublic HealthRadiationResearchSavingsSmall Business Innovation Research GrantSpeedSystemTabletsTechnologyTestingTimeTrainingUltrasonographyVisionWorkX-Ray Computed Tomographybaseclinical practicecone-beam computed tomographydesignexperimental studyhigh resolution imaginginnovationinstrumentlensminimally invasivemonocularproduct developmentradiologist
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Clear Guide Medical, Inc.
Summary
In an earlier Phase II SBIR (Topic Number: SBIR 306; HHSN261201300062C; RFP: N44C031014-51),
Clear Guide Medical developed the Clear Guide SCENERGY, a compact guidance system for CT-
ultrasound fusion and easy instrument guidance. Building on this fundamental technology, Clear Guide
Medical proposes to make the SCENERGY CT-only, without the use of real-time ultrasound. Feedback
from potential customers in interventional radiology has indicated that many physicians prefer to use
only CT-guidance without adding ultrasound to the procedure, which is a change to their existing
workflow. This present application outlines the steps to adapt the existing FDA-cleared SCENERGY to
that market.
This application describes the technological research plan to address key technical product
developments and to obtain some of the nonclinical but necessary data to support regulatory filings for
a CT-only SCENERGY in the future.
Public health implications of this proposal include significantly lowered radiation for CT-guided
interventional procedures, a benefit to patients and physicians alike. Additionally, there may be time
savings per procedure by reducing the number of CTs taken, as well as cost savings from greater
throughput per CT machine.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Low Cost Image Guidance for Improved Vessel Cannulation in Pediatric Patients
-
批准号:10018510
-
项目类别:
-
资助金额:$70.75万
-
财政年份:2019
-
负责人:Pezhman Foroughi
-
依托单位:
Low Cost Image Guidance for Improved Vessel Cannulation in Pediatric Patients
-
批准号:9622489
-
项目类别:
-
资助金额:$23.44万
-
财政年份:2018
-
负责人:Pezhman Foroughi
-
依托单位:
海外基金