课题基金 / 基金详情

Study on the dose distribution measurement precision in the radiotherapy using GAFchromic film

Study on the dose distribution measurement precision in the radiotherapy using GAFchromic film
GAF变色胶片放射治疗剂量分布测量精度研究
批准号:
14570859
负责人:
AZUMA Yoshiharu
金额:
$1.22万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2002
资助国家:
日本
项目状态:
已结题
起止时间:
2002 至 2003

项目摘要

项目成果

AZUMA Yoshiharu的其他基金

相似基金

相关文献

中文摘要
翻译
在放射治疗领域,必须评估复杂的剂量分布,并要求剂量评估具有较高的精度。放射致色膜作为一种进行二维剂量分布评估的辐射计,近年来得到了广泛的发展和关注。薄膜的密度不均匀性以及薄膜与密度测量仪的匹配直接影响测量误差。然后,在研究薄膜密度不均匀性的同时,分析了辐照前光密度对辐照后光密度的影响,并考虑了这种影响的校正过程。首先,对由1710型激光密度计和MD-55-2型Gafchromic胶片组成的剂量测量系统进行了密度测量精度的检验,并通过在1-60 Gy范围内形成密度数据的二维图像观察到是否存在伪影。因此,当需要高度精细像素级的测量精度时,例如在3D-CRT或IMRT中进行复杂的剂量分布评估时,我们认为有必要进一步增加以双曝光技术为代表的密度不均匀性校正过程。此外,辐照后的样品像素值也随着辐照前的样品像素值变高而变高。此外,由于两个样本像素值之间的关系可以线性近似,因此采用每次照射前每个样本像素值建立吸收剂量到像素值的转换曲线,照射后对样本像素值进行校正的程序。通过该方法,可以获得比仅使用传统的吸收剂量到像素值的转换曲线进行精度测量更高的测量结果。
英文摘要
In the radiotherapy field, a complicated dose distribution must be evaluated and it is required that dose assessment should have the high precision. As the radiometer that performs dose distribution assessment of 2-dimensional one, Radiochromic film is developed and attracts attention. The density ununiformity of the film and the matching with the film and a density-measuring instrument are directly involved in a measurement error directly. Then, while investigating about the ununiformity of the density of the film in this study, the influence, which the optical density before irradiation has on the density after irradiation, was analyzed, and the correction procedure of he influence was considered. First, to dosimetry system, which consists of Laser Densitometer Model 1710 for an x-ray film and Gafchromic film MD-55-2, the check of density measurement precision was performed and the existence of the artifact by the formation, of a 2-dimensional picture of density data was observed in 1-60 Gy. Consequently, in case where the measurement precision in highly detailed pixel level is required, such as performing complicated dose distribution assessment in 3D-CRT or IMRT, it was thought to be necessary to add further the correction process of density ununiformity that is represented by double exposure technique. Furthermore, it turned out that the sample pixel value after irradiation also becomes high as the sample pixel value before irradiation became high. Moreover, since the linear approximation, was possible in the relation between both sample pixel values, the procedure of creating conversion curve of an absorbed dose to a pixel value for every sample pixel value before each irradiation, and correcting the sample pixel value after irradiation was adopted. By this procedure, the measurement result higher than the measurement performed only with the conventional conversion curve of an absorbed dose to a pixel value for precision could be obtained.
期刊论文(6)
专著(0)
科研奖励(0)
会议论文
Hideki Aoyama: "The absorbed dose evaluation of the radiation therapy of the early glottic cancer by the difference in X-rays energy 'Investigation with the film type dosimeter'"The Journal of JASTRO. Vol.14 No.4. 239-245 (2002)
青山英树:“通过X射线能量的差异评估早期声门癌放射治疗的吸收剂量‘用胶片式剂量计进行的调查’”JASTRO杂志。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
青山 英樹: "X線エネルギーの違いによる早期声門癌治療の吸収線量評価-フィルムタイプ線量計を用いた検討-"日本放射線腫瘍学会誌. 14・4. 239-245 (2002)
青山秀树:“基于X射线能量差异的早期声门癌治疗中吸收剂量的评估 - 使用胶片型剂量计的研究 -”日本放射线肿瘤学会杂志14・4(2002)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Development of the dose distribution measurement equipment for Gafchromic film in radiotherapy
  • 批准号:
    16591205
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $1.79万
  • 财政年份:
    2004
  • 负责人:
    AZUMA Yoshiharu
  • 依托单位:
海外基金