Supplemental transmission aided attenuation correction for high performance quantitative PET imaging
Supplemental transmission aided attenuation correction for high performance quantitative PET imaging
批准号:
10222671
负责人:
Spencer L. Bowen
金额:
$8.65万
依托单位国家:
美国
项目类别:
财政年份:
2020
资助国家:
美国
项目状态:
已结题
起止时间:
2020-08-01 至 2024-05-31
关键词:
3-DimensionalAlgorithmsArtificial IntelligenceBiomedical EngineeringBrainCalibrationCardiacClinicalClinical TrialsDataDecision MakingDevelopmentDevicesDiagnosticDoseEquilibriumEquipmentGoalsGoldImageJoint repairJointsLeadMalignant neoplasm of prostateMeasurementMeasuresMethodsMissionModalityMonte Carlo MethodMotionNational Institute of Biomedical Imaging and BioengineeringNeuroendocrine TumorsNoiseOncologyPET/CT scanPatientsPerformancePhotonsPhysiologicalPositioning AttributePositron-Emission TomographyProtocols documentationPublic HealthRadiation Dose UnitRadiation ScatteringRadioactiveRadiology SpecialtyResearchScanningSchemeSeriesSignal TransductionSilverSourceTimeTissuesTracerTrainingTubeattenuationbasedata qualityexperimental studyfluorodeoxyglucoseimaging studyimprovedinnovationintelligent algorithmpatient safetypediatric patientsprototyperadiotracerreconstructionrespiratorytransmission processuptake
中文摘要
项目总结
英文摘要
PROJECT SUMMARY
Quantitative tracer images from combined PET-CT and PET-MR are increasingly being utilized for radiological
decision-making and clinical trials. CT and MR based data corrections for PET photon attenuation, typically the
largest impact on tracer quantification, can lead to increased radiation dose to the subject or require lengthy
additional dedicated MR scans, respectively. Artificial intelligence algorithms that use the PET signal
originating from the subject alone to estimate attenuation have shown promising early results, but, can have
reduced performance when applied to exams different from the training data. Reconstruction methods that
jointly estimate both the measured attenuation and tracer contrast from the subject PET signal represent a
viable alternative, but, to date, have failed to match the quantification of CT approaches. Consequently, no
single approach for PET attenuation correction that consistently produces high quantification and does not
compromise patient safety or throughput currently exists. This is an important problem, since research and
clinical findings must balance these practical issues with data quality. The overall objective of this proposal is
to develop and characterize a high performance attenuation correction scheme that utilizes both the PET
signal from the subject and a variable activity external source. The central hypothesis is that the proposed
reconstruction method will have significantly improved performance over reconstruction algorithms using PET
signal originating from the subject alone, independent of the imaging study. The two specific aims include: 1)
developing and validating a supplemental transmission-based algorithm for correcting PET images for photon
attenuation during commercial PET imaging and 2) prototyping and characterizing a device capable of
dynamically varying external source activity. The result of Aim 1 will be a reconstruction algorithm that is
optimized to produce quantitative PET data for some of the most common clinical PET studies. Under Aim 2, a
prototype device that can repeatability vary the external source activity in order to maximize tracer
quantification while minimizing the unavoidable degradation to patient tracer image noise, caused by the
introduction of any external source, will be produced. The innovation is an attenuation correction strategy that
greatly mitigates the limitations of previous joint reconstruction methods to deliver quantitative PET diagnostics
that are expected to match those of silver standard CT approaches. This is significant because the number of
patients receiving brain and cardiac PET-CT scans, exams the proposed method is expected to benefit, is
steadily increasing. For PET-MR, the method may improve tracer quantification where MR has limited
performance and increase patient throughput by eliminating the need for non-diagnostic attenuation-only MR
acquisitions. Thus, the proposed strategy has great potential to significantly improve radiological decision-
making and clinical trial findings that rely on quantitative PET uptake measurements.
期刊论文(1)
专著(0)
科研奖励(0)
会议论文
Supplemental transmission aided attenuation correction for high performance quantitative PET imaging
-
批准号:10308169
-
项目类别:
-
资助金额:$8.63万
-
财政年份:2020
-
负责人:Spencer L. Bowen
-
依托单位:
Ultraportable Stroke CT Based on Stationary Carbon Nanotube X-ray Source and Deep Learning Image Formation
-
批准号:9909721
-
项目类别:
-
资助金额:$22.51万
-
财政年份:2019
-
负责人:Spencer L. Bowen
-
依托单位:
海外基金