Nanowire Devices for Ultrasensitive, Multiplexed Detection of Cancer Markers
Nanowire Devices for Ultrasensitive, Multiplexed Detection of Cancer Markers
批准号:
7454063
负责人:
CHARLES M LIEBER
金额:
$18.49万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2008
资助国家:
美国
项目状态:
已结题
起止时间:
2008-04-01 至 2010-03-31
关键词:
AddressAffectAntibodiesAntigensAreaBindingBiologicalBiological AssayBiological ModelsBiological TestingBuffersCancer DetectionCharacteristicsClassificationCompetenceCoupledDetectionDevelopmentDevicesDiagnosisDiagnosticDiscriminationElectronicsEnvironmentEquilibriumFc ReceptorFluorescenceGoalsGrowthIonic StrengthsLinkLiquid substanceMalignant NeoplasmsMeasurementMethodologyMethodsModelingModificationMonitorMonoclonal AntibodiesOperative Surgical ProceduresPerformancePlayProcessPropertyProteinsProtocols documentationPublic HealthReproducibilityResearchSamplingSerumSerum ProteinsSiliconSolutionsStagingSurfaceTechnologyTestingTimeTransistorsbasecancer recurrencedesigndetectorelectrical measurementfallshuman diseaseimprovedlink proteinnanodevicenanoelectronicsnanowirereceptorresponsesensor
中文摘要
描述(申请人提供):该项目的总体目标是开发一种强大的基于硅纳米线的纳米电子传感器技术,用于快速、超灵敏和定量多路检测癌症标记蛋白。化学合成的硅纳米线可以提供组装可重现场效应探测器阵列所需的均匀度,而用特定的受体修饰这些纳米设备的表面将使癌症标志物的实时、超灵敏电子检测成为可能。拟议的研究将涉及四个具体的研究领域。首先,将开发一种健壮的、可寻址的纳米线传感器芯片和有效的芯片接口。大规模的硅纳米线生长将与晶片规模的组装相结合,结果将进行优化,以产生高效的芯片制造工艺,从而实现良好的器件成品率和高效的芯片产量。将开发和验证一种新的芯片接口,使其能够实现与测量仪器的简单“即插即用”互连。将进行大规模的器件表征,以确定纳米线晶体管特性的统计重复性,并优化这些特性。其次,将开发一种将抗体受体阵列与功能纳米线设备阵列连接起来的可重复使用的方法。用于癌症标志物的单抗阵列将使用微阵列连接到纳米线设备阵列,受体阵列的保真度和功能将使用荧光和电子结合分析来确定。第三,定义了影响纳米线传感器性能的关键因素和限制。对抗体修饰的纳米线设备阵列芯片的系统研究将用于确定关键性能因素,包括(I)设备基线和检测稳定性,(Ii)作为缓冲离子强度函数的检测灵敏度,(Iii)对假阳性/假阴性反应的选择性和辨别,以及(Iv)定量浓度分析方法。此外,还将调查纳米线设备阵列中多路复用检测的限制。第四,将确定纳米线器件芯片的特征和血清样本的限值。作为离子强度函数的血清分析中的蛋白质检测限度,以及选择性多重检测的限度,包括假阳性与非选择性结合和定量浓度分析的区分将被表征。拟议的研究具有广泛的意义,(1)可以使用现有的诊断标记物进行早期诊断和癌症复发的检测,(2)通过检测和监测新出现的癌症标记物组来实现高度可靠的诊断和治疗,(3)可以普遍应用于其他人类疾病的早期诊断和监测。
这个项目的总体目标是开发一种纳米电子传感器技术,用于快速、超灵敏和定量地同时检测多种癌症标记物蛋白质。这项拟议的研究具有广泛的意义,有望(1)利用现有的诊断标记物实现癌症的早期诊断和复发检测;(2)通过检测和监测新出现的癌症标记物组,实现高度可靠的诊断和治疗;(3)成为人类疾病快速早期诊断和监测的通用技术。
英文摘要
DESCRIPTION (provided by applicant): The overall goal of this project is to develop a robust silicon nanowire-based nanoelectronic sensor technology for rapid, ultra-sensitive and quantitative multiplexed detection of cancer marker proteins. Chemically-synthesized silicon nanowires can provide the uniformity needed for assembly of arrays of reproducible field-effect detectors, and modification of the surfaces of these nanodevices with specific receptors will enable real-time, ultra-sensitive electronic detection of cancer markers. The proposed research will address four specific research areas. First, a robust, addressable nanowire sensor chip and effective chip interface will be developed. Large-scale silicon nanowire growth will be coupled with wafer scale assembly, and the results will be optimized to yield an efficient chip fabrication process that enables good device yield and efficient chip through-put. A new chip interface that enables simple `plug-and-play' interconnection to measurement apparatus will be developed and validated. Large-scale device characterization will be carried out to determine statistical reproducibility of the nanowire transistor properties, and to optimize these properties. Second, a reproducible methodology for linking antibody receptor arrays to functional nanowire device arrays will be developed. Monoclonal antibodies arrays for cancer markers will be linked to the nanowire device arrays using a microarrayer, and the fidelity and competence of the receptors arrays will determine using fluorescence and electrical binding assays. Third, key factors and limits on the nanowire sensor performance will be defined. Systematic studies of the antibody-modified nanowire device array chips will be used to determine key performance factors, including (i) device baseline and detection stability, (ii) detection sensitivity as a function of buffer ionic strength, (iii) selectivity and discrimination against false positive/false negative responses, and (iv) methods for quantitative concentration analysis. In addition, limits for multiplexed detection in the nanowire device arrays will be investigated. Fourth, nanowire device chip characteristics and limits for serum samples will be determined. Protein detection limits in serum analysis as a function of ionic strength, and limits for selective multiplexed detection, including discrimination of false positives from nonselective binding and quantitative concentration analysis will be characterized. The proposed research has broad significance and (1) could enable early stage diagnosis and detection of recurrence of cancer using current diagnostic markers, (2) allow for highly robust diagnosis and treatment by detection and monitoring of panels of emerging cancer markers, and (3) could be generally applied for early stage diagnosis and monitoring of other human diseases.
PUBLIC HEALTH RELEVANCE The overall goal of this project is to develop a nanoelectronic sensor technology for rapid, ultra-sensitive and quantitative simultaneous detection of multiple cancer marker proteins. The proposed research has broad significance and promises to (1) enable early stage diagnosis and detection of recurrence of cancer using current diagnostic markers, (2) allow for highly robust diagnosis and treatment by detection and monitoring of panels of emerging cancer markers, and (3) become a general technology for rapid early stage diagnosis and monitoring of human disease.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Syringe-Injectable Mesh Electronics for Seamless Integration with the Central Nervous System
-
批准号:9754135
-
项目类别:
-
资助金额:$118.3万
-
财政年份:2017
-
负责人:CHARLES M LIEBER
-
依托单位:
Syringe-Injectable Mesh Electronics for Seamless Integration with the Central Nervous System
-
批准号:9341423
-
项目类别:
-
资助金额:$118.3万
-
财政年份:2017
-
负责人:CHARLES M LIEBER
-
依托单位:
SI NANOWIRE
-
批准号:8168599
-
项目类别:
-
资助金额:$0.65万
-
财政年份:2010
-
负责人:CHARLES M LIEBER
-
依托单位:
Nanowire Devices for Ultrasensitive, Multiplexed Detection of Cancer Markers
-
批准号:7597118
-
项目类别:
-
资助金额:$16.98万
-
财政年份:2008
-
负责人:CHARLES M LIEBER
-
依托单位:
Nanowire Nanoelectronic/Cell Assemblies as Hybrid Functional Biomaterials
-
批准号:7918026
-
项目类别:
-
资助金额:$84.0万
-
财政年份:2008
-
负责人:CHARLES M LIEBER
-
依托单位:
Nanowire Nanoelectronic/Cell Assemblies as Hybrid Functional Biomaterials
-
批准号:8119451
-
项目类别:
-
资助金额:$83.16万
-
财政年份:2008
-
负责人:CHARLES M LIEBER
-
依托单位:
Nanowire Nanoelectronic/Cell Assemblies as Hybrid Functional Biomaterials
-
批准号:8306936
-
项目类别:
-
资助金额:$83.16万
-
财政年份:2008
-
负责人:CHARLES M LIEBER
-
依托单位:
Nanowire Nanoelectronic/Cell Assemblies as Hybrid Functional Biomaterials
-
批准号:7692282
-
项目类别:
-
资助金额:$84.0万
-
财政年份:2008
-
负责人:CHARLES M LIEBER
-
依托单位:
Carbon Nanotube Probes for Direct DNA Sequence Analysis
-
批准号:6776939
-
项目类别:
-
资助金额:$53.77万
-
财政年份:2001
-
负责人:CHARLES M LIEBER
-
依托单位:
Carbon Nanotube Probes for Direct DNA Sequence Analysis
-
批准号:6335311
-
项目类别:
-
资助金额:$28.46万
-
财政年份:2001
-
负责人:CHARLES M LIEBER
-
依托单位:
Carbon Nanotube Probes for Direct DNA Sequence Analysis
-
批准号:6776252
-
项目类别:
-
资助金额:$65.47万
-
财政年份:2001
-
负责人:CHARLES M LIEBER
-
依托单位:
Carbon Nanotube Probes for Direct DNA Sequence Analysis
-
批准号:6515093
-
项目类别:
-
资助金额:$15.7万
-
财政年份:2001
-
负责人:CHARLES M LIEBER
-
依托单位:
HIGH RESOLUTION IMAGING WITH CARBON NANOTUBE PROBES
-
批准号:6193066
-
项目类别:
-
资助金额:$19.59万
-
财政年份:2000
-
负责人:CHARLES M LIEBER
-
依托单位:
HIGH RESOLUTION IMAGING WITH CARBON NANOTUBE PROBES
-
批准号:6386526
-
项目类别:
-
资助金额:$20.06万
-
财政年份:2000
-
负责人:CHARLES M LIEBER
-
依托单位:
HIGH RESOLUTION IMAGING WITH CARBON NANOTUBE PROBES
-
批准号:6520054
-
项目类别:
-
资助金额:$20.38万
-
财政年份:2000
-
负责人:CHARLES M LIEBER
-
依托单位:
ELECTRON TRANSFER RATES IN METALLOENZYME MODELS
-
批准号:3040869
-
项目类别:
-
资助金额:$1.72万
-
财政年份:1986
-
负责人:CHARLES M LIEBER
-
依托单位:
ELECTRON TRANSFER RATES IN METALLOENZYME MODELS
-
批准号:3040868
-
项目类别:
-
资助金额:$1.9万
-
财政年份:1985
-
负责人:CHARLES M LIEBER
-
依托单位:
海外基金