课题基金 / 基金详情

Monitoring of Cardiovascular Function in Infants By Transcutaneous Dye Dilution

Monitoring of Cardiovascular Function in Infants By Transcutaneous Dye Dilution
通过经皮染料稀释监测婴儿心血管功能
批准号:
8310254
负责人:
DANIEL PHILIPP HOLSCHNEIDER
金额:
$41.49万
依托单位国家:
美国
项目类别:
财政年份:
2010
资助国家:
美国
项目状态:
已结题
起止时间:
2010-07-01 至 2014-06-30
关键词:
AccountingAcuteAddressAdultAdvisory CommitteesAffectBackBiomedical TechnologyBloodBlood PressureBlood VolumeBlood flowBlood specimenBody SizeCalibrationCardiacCardiac OutputCardiovascular DiseasesCardiovascular PhysiologyCardiovascular systemCathetersChildhoodClinicalClinical ResearchClinical TrialsClinical assessmentsClipComputer softwareCritical CareCritical IllnessCutaneousDetectionDevelopmentDialysis procedureDyesEchocardiographyEnsureEquationEtiologyEvans blue stainFDA approvedFluorescenceFluorescent DyesFosteringGoalsHealthHemodialysisHumanHypersensitivity skin testingHypovolemiaIndocyanine GreenInfantInjection of therapeutic agentIntensive CareInterdisciplinary StudyIntravenous BolusKidneyLasersLeadLos AngelesMaintenanceMeasurementMeasuresMedicalMedicineMethodsModelingMonitorMyocardial dysfunctionNational Center for Research ResourcesNeonatalNewborn InfantOpticsOryctolagus cuniculusOutpatientsPatientsPediatric HospitalsPerfusionPeripheral ResistancePharmaceutical PreparationsPhysiologic arteriovenous anastomosisPlayProcessPulmonary artery structureRadiolabeledRecruitment ActivityReportingResearchResearch PriorityRiskRoleRuralShockSideSignal TransductionSiteSkinSourceSpectrophotometryStrategic PlanningStroke VolumeSystemTechniquesTechnologyTestingThermodilutionTissuesTracerTranslatingTranslationsUltrafiltrationValidationVariantVenousbaseblood perfusioncost effectivedesignfallsfetalheart imaginghemodynamicshuman subjectimprovedin vivoinnovationinstrumentinstrumentationinterestlight intensityminimally invasivemonitoring deviceneonatepatient populationpublic health relevanceradiotracer

项目摘要

项目成果

DANIEL PHILIPP HOLSCHNEIDER的其他基金

相似基金

相关文献

中文摘要
翻译
描述(由申请人提供):心输出量(CO)和心脏前负荷(中心血容量,CBV)和全身血管阻力(SVR)的测量值是循环功能的关键临床参数。热稀释技术是测量CO的公认标准。然而,在新生儿和婴儿中,放置和维护此类测量所需的肺动脉导管在技术上具有挑战性,并且与导管相关并发症相关。血容量测量可以定量进行,然而,这些通常涉及放射性标记示踪剂的注射和/或大量的连续血液采样,并且很少进行。事实上,目前主要根据血压和其他间接的、相当不可靠的组织灌注体征来做出关于治疗这些患者低灌注状态(休克)的临床决策。这些局限性促使人们研究更新的、侵入性更小的技术。我们最近描述了一种新的指示剂稀释方法和仪器,用于评估CO、循环血容量(BV)、CBV和SVR,其基于FDA批准的药物吲哚菁绿色(ICG)的静脉推注和循环血ICG荧光的光学测量。我们现在建议开发和验证皮肤探头,它可以用来测量心血管参数transmittance。挑战在于皮肤灌注是动态的,这会影响荧光信号的强度。我们建议通过设计一种探头来解释这种变化,该探头将循环ICG的光学荧光测量与使用成熟的激光多普勒技术测量皮肤部位的局部血液灌注相结合。这将使我们能够调整我们的荧光染料稀释信号,以准确地导出CO,CBV和SVR,而不管局部皮肤灌注的变化。目的1是在兔模型中开发和验证这样的皮肤探针。目的2是在USC/DaVita肾脏中心接受门诊血液透析的成人受试者中验证临床级皮肤探针。目的3是在洛杉矶儿童医院新生儿和婴儿重症监护室的新生儿和婴儿中测试探头,并将CO值与功能性超声心动图获得的CO值进行比较。目前,存在对微创技术的强烈临床需求,该微创技术可以提供新生儿和婴儿的心脏功能的快速、连续测量。所提出的技术将导致开发一种实用的设备,用于监测重症监护、手术和术后环境中最小器械新生儿以及病情不适合使用中央监测的患者的CO。该应用程序响应NHLBI的研究优先级,以改进心脏成像技术(儿科心血管疾病研究工作组报告,2002年),以及战略重点(2009-2013年)将生物医学技术创新纳入临床研究,和NIBIB的战略计划(2006年),以促进跨学科研究,加速转化有前途的技术,以改善人类健康。 公共卫生相关性:目前,存在对微创技术的强烈临床需求,其可以为危重新生儿和婴儿提供心脏功能和循环血容量的快速、连续测量,危重新生儿和婴儿的小身体尺寸使得更具侵入性的方法(肺动脉热稀释导管)在技术上具有挑战性并且与显著风险相关。事实上,关于低灌注状态(休克)的治疗的临床决策目前主要基于血压和其他间接的、相当不可靠的组织灌注迹象。我们的提案通过开发和验证光学探头来满足这一需求,该光学探头可用于通过皮肤测量心脏功能,用于新生儿重症监护和病情不适合使用更具侵入性监测的患者。
英文摘要
DESCRIPTION (provided by applicant): Cardiac output (CO) and measures of cardiac preload (central blood volume, CBV) and systemic vascular resistance (SVR) are critical clinical parameters of circulatory function. The thermodilution technique is the accepted standard for measurement of CO. However, placement and maintenance of a pulmonary artery catheter required for such a measurement is technically challenging in neonates and infants and is associated with catheter-associated complications. Blood volume measurements can be performed quantitatively, however, these typically involve injection of radiolabelled tracers and/or extensive serial blood sampling and are infrequently performed. In fact, clinical decisions about the treatment of low perfusion states (shock) in these patients are currently being made based primarily on blood pressure and other indirect, fairly unreliable signs of tissue perfusion. These limitations have motivated studies of newer, less invasive techniques. We recently described a new indicator dilution method and instrumentation for assessing CO, circulating blood volume (BV), CBV, and SVR that is based on an intravenous bolus injection of the FDA-approved drug indocyanine green (ICG) and optical measurement of circulating blood ICG fluorescence. We now propose to develop and validate a skin probe, which can be used to measure cardiovascular parameters transcutaneously. The challenge is that skin perfusion is dynamic, which can affect the intensity of the fluorescence signal. We propose to account for this variability by designing a probe that combines the optical fluorescence measurements of circulating ICG with the measurement of local blood perfusion at the skin site using the well-established laser Doppler technique. This would allow us to adjust our fluorescence dye dilution signals to accurately derive CO, CBV, and SVR, irrespective of changes in local skin perfusion. Aim 1 is to develop and validate such a skin probe in a rabbit model. Aim 2 is to validate a clinical grade skin probe in adult subjects undergoing outpatient hemodialysis at the USC/DaVita Kidney Center. Aim 3 is to test the probe in neonates and infants in the Newborn and Infant Critical Care Unit at Children's Hospital Los Angeles and compare CO values with those obtained by functional echocardiography. Currently, a strong clinical need exists for a minimally invasive technique, which can provide rapid, serial measurements of cardiac function in neonates and infants. The proposed technique will lead to the development of a practical device for monitoring CO in minimally instrumented neonates in intensive care, operative and postsurgical settings, and in patients whose condition does not justify the use of central monitoring. This application is responsive to the NHLBI's research priority for improved technologies to image the heart (Task Force Report on Research in Pediatric Cardiovascular Disease, 2002), as well as the strategic priority (2009-2013) of the NCRR to incorporate innovations in biomedical technology into clinical research, and the NIBIB's Strategic Plan (2006) to foster interdisciplinary research for the accelerated translation of promising technologies to improve human health. PUBLIC HEALTH RELEVANCE: Currently, a strong clinical need exists for a minimally invasive technique, which can provide rapid, serial measurements of cardiac function and circulating blood volume in critically ill neonates and infants whose small body size renders more invasive methods (pulmonary artery thermodilution catheter) technically challenging and associated with significant risk. In fact, clinical decisions about the treatment of low perfusion states (shock) are currently being made based primarily on blood pressure and other indirect, fairly unreliable signs of tissue perfusion. Our proposal addresses this need with the development and validation of an optical probe, which can be used to measure cardiac function through the skin for applications in neonatal critical care and in patients whose condition does not justify the use of more invasive monitoring.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Positive allosteric modulation of cholinergic receptors in recovery after brain trauma
  • 批准号:
    9093336
  • 项目类别:
  • 资助金额:
    $24.95万
  • 财政年份:
    2016
  • 负责人:
    DANIEL PHILIPP HOLSCHNEIDER
  • 依托单位:
Functional Adaptation of Neural Circuits After Exercise and Basal Ganglia Injury
  • 批准号:
    8278581
  • 项目类别:
  • 资助金额:
    $32.27万
  • 财政年份:
    2010
  • 负责人:
    DANIEL PHILIPP HOLSCHNEIDER
  • 依托单位:
Monitoring of Cardiovascular Function in Infants By Transcutaneous Dye Dilution
  • 批准号:
    8116633
  • 项目类别:
  • 资助金额:
    $37.63万
  • 财政年份:
    2010
  • 负责人:
    DANIEL PHILIPP HOLSCHNEIDER
  • 依托单位:
Functional Adaptation of Neural Circuits After Exercise and Basal Ganglia Injury
  • 批准号:
    8676824
  • 项目类别:
  • 资助金额:
    $31.37万
  • 财政年份:
    2010
  • 负责人:
    DANIEL PHILIPP HOLSCHNEIDER
  • 依托单位:
海外基金