An Advanced Technology Flat-Panel Imager for Fluoroscopy
An Advanced Technology Flat-Panel Imager for Fluoroscopy
批准号:
7656521
负责人:
LARRY E ANTONUK
金额:
$135.81万
依托单位国家:
美国
项目类别:
财政年份:
2002
资助国家:
美国
项目状态:
已结题
起止时间:
2002-08-01 至 2013-03-31
关键词:
AdoptionAlgorithmsAmplifiersArchitectureAreaBehaviorBreastCardiacChargeChestCollaborationsComplexComputer softwareConceptionsCoupledCrystallizationDetectionDevelopmentDoseEvaluationExhibitsFilmFluoroscopyFrequenciesGoalsImageImage EnhancementImageryImaging TechniquesImaging technologyIndividualInvestigationLasersMammographyMeasurementMechanicsMedicalMetricModelingMorphologic artifactsNoisePatient CarePatientsPerformanceProceduresProcessPropertyQuantitative EvaluationsRadiationResearchResolutionRoentgen RaysSeriesSignal TransductionSiliconStructureStudy modelsSystemSystems AnalysisTechniquesTechnologyTestingThoracic RadiographyTransistorsUnited States National Institutes of Healthbaseclinical applicationcone-beam computed tomographydesigndetectordigitalexpectationimprovedinnovationiterative designmodel developmentnew technologynovelpractical applicationprogramsprototypepublic health relevancequantumsimulationstatisticstool
中文摘要
描述(申请人提供):自20世纪80年代以来的广泛研究工作已导致有源矩阵平板成像仪(AMFP)在这十年中被实际引入到许多医疗X射线应用中。这些包括涉及锥束计算机断层扫描(CBCT)的成像程序。虽然与传统的胶片屏幕和X射线图像增强系统(XRII)相比,AMFPI提供了许多优势,但该技术仍然受到几个重大限制。AMFPI图像质量在低曝光时会降低,因此,例如,它无法在整个透视曝光范围内与XRII的图像质量相匹配。其次,AMFPI容易受到图像伪影的影响,这种伪影源于阵列中非晶态材料中电荷的捕获。当大量射线曝光后不久获得透视图像时,这种伪影尤其突出--这种现象被称为重影。最后,AMFPI的最大可实现帧速率是受限的。导致这一提议的研究已经确定了一种创新的、非常有希望的战略来克服这些限制,包括用多晶硅(多晶硅)TFT取代大多数传统AMFP中使用的非晶硅薄膜晶体管(a-Si:H TFT)。这允许创建更复杂的具有像素内放大器的阵列--称为有源像素(AP)架构。再加上与这些更复杂的像素电路兼容的新型a-Si:H光电二极管结构的结合,多晶硅AP阵列将克服上述各种限制,同时保留传统AMFP的许多有利特性。研究的目标集中在开发一系列性能越来越高、面积越来越小的原型阵列,这些阵列表现出这些理想的特性。目标是:(1)开发性能逐渐更好的原型(更高的探测量子效率、更低的电荷捕获效应、更高的帧速率)--包括迭代设计、制造和评估日益复杂的AP原型。(2)定量建模(包括级联系统分析和详细的电路仿真),为阵列设计提供指导,并协助原型评估。(3)详细描述单个多晶硅TFT和其他测试电路的特性,以支持电路模拟活动,并为通过改进制造技术来提高阵列性能提供指导。(4)创造完成上述目标所需的各种工具(数学、软件、固件和硬件)。这项研究的成功结论将导致创建一种技术,该技术提供的图像质量仅受X射线和X射线转换器的基本属性限制,减少伪影并提高帧速率。最终,这将提高图像质量和/或减少荧光检查程序的剂量,并促进先进的临床应用,包括乳房和胸部断层合成,以及用于乳房和血管造影程序的CBCT。公共卫生相关性:拟议研究中将开发的新型X射线成像技术的实际应用将显著增强成像能力,最终以多种方式改善患者护理。例如,与现有的X射线技术相比,新技术将有助于以极低的剂量实现更高质量的图像(有助于将透视过程中对患者的剂量降至最低),并使较小和/或较低对比度的特征能够可视化(有助于在乳房X光检查中识别可疑物体)。此外,人们强烈预计,这项新技术将使先进的应用(包括用于胸部和乳房成像的断层合成或锥形束计算机断层扫描技术)成为可能,这些应用需要以相对较低的每张图像剂量快速获取多幅高质量图像,以便生成三维解剖图像。
英文摘要
DESCRIPTION (provided by applicant): Extensive research efforts since the 1980s have resulted in the practical introduction of active-matrix flat-panel imagers (AMFPIs) to numerous medical x-ray applications in this decade. These include \ imaging procedures involving cone beam computed tomography (CBCT). While AMFPIs offer many advantages compared to traditional film-screen and x-ray image intensifier systems (XRIIs), the technology nevertheless suffers from several significant limitations. AMFPI image quality degrades at low exposures so that, for example, it cannot match the image quality of XRIIs across the entire fluoroscopic exposure range. Secondly, AMFPIs are subject to image artifacts, originating from the trapping of charge in amorphous materials in the arrays. Such artifacts are particularly prominent when fluoroscopic images are acquired shortly after a large radiographic exposure - a phenomenon called ghosting. Finally, the maximum achievable frame rates of AMFPIs are restrictive. Research leading up to this proposal has identified an innovative, highly promising strategy for overcoming these limitations, involving substitution of the amorphous silicon thin-film transistors (a-Si:H TFTs), used in most conventional AMFPIs, with polycrystalline silicon (poly-Si) TFTs. This allows creation of considerably more sophisticated arrays with in-pixel amplifiers - referred to as an active pixel (AP) architecture. Coupled with the incorporation of novel a-Si:H photodiode structures that are compatible with these more complex pixel circuits, poly-Si AP arrays would overcome the various limitations listed above, while preserving the many favorable properties of conventional AMFPIs. The objectives of the research focus on the development of a series of increasingly higher performance, small area, prototype arrays that exhibit these desirable properties. The objectives are: (1) Development of prototypes with progressively better performance (higher detective quantum efficiency, lower charge trapping effects, higher frame rates) - involving iterative design, fabrication and evaluation of increasingly sophisticated AP prototypes. (2) Quantitative modeling (involving cascaded systems analysis and detailed circuit simulations) to provide guidance in array design and assist in prototype evaluation. (3) Detailed characterization of the properties of individual poly-Si TFTs and other test circuits to support the circuit simulation activities and to provide guidance in improving array performance through improvements to fabrication techniques. (4) Creation of the various tools (mathematical, software, firmware and hardware) required to accomplish the above objectives. The successful conclusion of this research will result in the creation of a technology that offers image quality limited only by the fundamental properties of X rays and x-ray converters, reduces artifacts and increases frame rates. Ultimately, this will improve image quality and/or reduce dose for fluoroscopic procedures, as well as facilitate advanced clinical applications including breast and chest tomosynthesis, and CBCT for breast and angiographic procedures. PUBLIC HEALTH RELEVANCE: The practical application of the novel x-ray imaging technology to be developed in the proposed research will offer significant enhancement of imaging capabilities, ultimately improving patient care in a wide variety of ways. For example, compared to existing x-ray technologies, the new technology will facilitate the realization of higher quality images at very low doses (helping to minimize dose to the patient in fluoroscopic procedures) and enable the visualization of smaller and/or lower contrast features (assisting in the identification of suspicious objects in mammographic examinations). Moreover, it is strongly anticipated that the new technology will enable advanced applications (involving tomosynthesis or cone beam computed tomography techniques for chest and breast imaging) that require rapid acquisition of multiple, high quality images at relatively low doses per image in order to produce three dimensional anatomical views.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Development of a High Sensitivity, X-ray Detector Technology Based on Polycrystalline Mercuric Iodide for Volumetric Breast Imaging
-
批准号:9236895
-
项目类别:
-
资助金额:$64.99万
-
财政年份:2016
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:8249853
-
项目类别:
-
资助金额:$136.46万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:6548375
-
项目类别:
-
资助金额:$104.35万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:7810684
-
项目类别:
-
资助金额:$137.58万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:8054213
-
项目类别:
-
资助金额:$135.94万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:6775698
-
项目类别:
-
资助金额:$110.03万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
An Advanced Technology Flat-Panel Imager for Fluoroscopy
-
批准号:6619730
-
项目类别:
-
资助金额:$106.93万
-
财政年份:2002
-
负责人:LARRY E ANTONUK
-
依托单位:
HYBRID, FLAT-PANEL, ACTIVE MATRIX MAMMOGRAPHIC IMAGER
-
批准号:6150266
-
项目类别:
-
资助金额:$78.41万
-
财政年份:1998
-
负责人:LARRY E ANTONUK
-
依托单位:
HYBRID, FLAT-PANEL, ACTIVE MATRIX MAMMOGRAPHIC IMAGER
-
批准号:2452354
-
项目类别:
-
资助金额:$66.57万
-
财政年份:1998
-
负责人:LARRY E ANTONUK
-
依托单位:
HYBRID, FLAT-PANEL, ACTIVE MATRIX MAMMOGRAPHIC IMAGER
-
批准号:2871989
-
项目类别:
-
资助金额:$67.98万
-
财政年份:1998
-
负责人:LARRY E ANTONUK
-
依托单位:
HYBRID, FLAT-PANEL, ACTIVE MATRIX MAMMOGRAPHIC IMAGER
-
批准号:6350260
-
项目类别:
-
资助金额:$68.69万
-
财政年份:1998
-
负责人:LARRY E ANTONUK
-
依托单位:
ADVANCED TECHNOLOGY FLAT PANEL IMAGER FOR FLUOROSCOPY
-
批准号:6375924
-
项目类别:
-
资助金额:$85.93万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
ADVANCED TECHNOLOGY FLAT PANEL IMAGER FOR FLUOROSCOPY
-
批准号:6171879
-
项目类别:
-
资助金额:$84.87万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X--AN OPTIMIZED FLAT-PANEL DIGITAL X-RAY IMAGER
-
批准号:2443011
-
项目类别:
-
资助金额:$70.93万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X A FLAT PANEL IMAGER FOR DIGITAL FLUOROSCOPY
-
批准号:2097128
-
项目类别:
-
资助金额:$53.12万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X--AN OPTIMIZED FLAT-PANEL DIGITAL X-RAY IMAGER
-
批准号:2097129
-
项目类别:
-
资助金额:$68.21万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X--AN OPTIMIZED FLAT-PANEL DIGITAL X-RAY IMAGER
-
批准号:2097130
-
项目类别:
-
资助金额:$68.66万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X A FLAT PANEL IMAGER FOR DIGITAL FLUOROSCOPY
-
批准号:3200646
-
项目类别:
-
资助金额:$52.27万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
ADVANCED TECHNOLOGY FLAT PANEL IMAGER FOR FLUOROSCOPY
-
批准号:2767473
-
项目类别:
-
资助金额:$86.9万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
MASDA-X A FLAT PANEL IMAGER FOR DIGITAL FLUOROSCOPY
-
批准号:3200647
-
项目类别:
-
资助金额:$50.9万
-
财政年份:1992
-
负责人:LARRY E ANTONUK
-
依托单位:
海外基金