Registered Ultrasound-Endoscope
Registered Ultrasound-Endoscope
批准号:
8109924
负责人:
Sharif Razzaque
金额:
$36.31万
依托单位国家:
美国
项目类别:
财政年份:
2010
资助国家:
美国
项目状态:
已结题
起止时间:
2010-07-15 至 2012-05-31
关键词:
AbdomenAblationAddressAnatomyAnesthesia proceduresAnimalsCaliberClinicalClinical TrialsClinical effectivenessCognitiveCommunitiesDataDevicesDoctor of PhilosophyEffectivenessEndoscopesEquipmentEvaluationEyeFamily suidaeFeedbackFluoroscopyFutureGoalsGrantHandHepatobiliaryHumanImageImageryInjuryInstitutional Review BoardsInterventionLifeLiverMagnetismMedical centerMindMonitorMovementNatureNeedlesOperating RoomsOperative Surgical ProceduresOutcomeParticipantPatientsPerformancePhasePhysiciansPositioning AttributeProceduresQualitative EvaluationsQuantitative EvaluationsRelative (related person)ResearchRiskSafetySliceSpace PerceptionStructureSurgeonSurgical incisionsSystemTechnologyTestingTimeTissuesTrainingUltrasonic TransducerUltrasonographyWeight-Bearing stateefficacy testingergonomicsexpectationexperienceflexibilityhuman subjectimaging modalityimprovedinstrumentmeetingsminimally invasivenovelphase 1 studyprototypepublic health relevanceresearch and developmentskills trainingspatial relationshipstereoscopicsuccessusability
中文摘要
描述(由申请人提供):拟议的项目旨在促进灵活的腹腔镜超声换能器在微创手术中的使用,以降低伤害率。在标准的腹腔镜手术中,外科医生通过腹部的小切口进行手术,同时在远程视频监视器上查看内部解剖结构,从而造成眼-手-器械的空间协调问题。正因为如此,在管理信息系统过程中会发生许多伤害。腹腔镜超声提供了对解剖的更全面的了解,为腹腔镜摄像机图像提供了补充的解剖信息,从而降低了受伤的风险。然而,它的使用加剧了传统管理信息系统固有的空间协调问题,因为相同的解剖特征在两种成像模式下表现得非常不同。在没有广泛经验的情况下,精确放置介入器械(如针头)变得特别困难。该项目的引导系统解决了这个问题,该系统向外科医生展示了他的器械是如何相对于超声扫描中的特征进行定位的。一期系统的动态立体图像显示了针的当前位置和方向以及未来的轨迹,并与实时超声图像相结合。针和超声扫描都以其实际的空间方向呈现给用户。在第一阶段,开发了一个原型系统,并对其有效性进行了测试。结果令人震惊:两名专家用户在没有我们指导的情况下将他们的放置准确率从60%提高到了100%;而两名新手用户(他们以前从未使用过超声波探头)从没有我们指导的5%提高到了100%。换句话说,如果没有我们的系统,新手用户就无法将针插入LUT视频中的特征中,因此他们不会错过。在这个第二阶段的项目中,我们建议(1)研究新的能力,以增加系统的实用性;以及(2)继续改进原型,以便在项目结束时,它将准备好在人类受试者身上进行临床试验。它将在多个动物研究中进行定量和定性测试。我们还将在临床环境中测试其可用性,并通过实验评估在整个第二阶段开发的新功能的可用性。
公共卫生相关性:我们建议开发一种先进的用于微创手术的立体可视化系统,该系统便于在管理信息系统干预期间使用腹腔镜超声,以降低患者的伤害率。该系统提供三维指导,将针或其他介入性器械准确地放置到腹腔镜超声图像中的结构中,以便外科医生可以更轻松、更安全地进行手术。
英文摘要
DESCRIPTION (provided by applicant): The proposed project aims to facilitate the use of flexible laparoscopic ultrasound transducers during minimally invasive surgery (MIS) in order to reduce injury rates. During a standard laparoscopic procedure, the surgeon operates through small incisions in the abdomen while viewing the internal anatomy on a remote video monitor, creating an eye-hand-instrument spatial coordination problem. Because of this, many injuries occur during MIS procedures. Laparoscopic ultrasound provides a more thorough understanding of the anatomy, offering complementary anatomical information to the laparoscopic camera image and thereby decreasing the risk of injury. However, its use aggravates the inherent spatial coordination problem of conventional MIS, since the same anatomical features appear very differently between the two imaging modalities. Precisely placing interventional instruments such as needles becomes particularly difficult without extensive experience.This problem is addressed with the guidance system of this project, which shows the surgeon how his instruments are positioned with respect to features in the ultrasound scan. The dynamic stereoscopic imagery of the Phase I system shows the current position and orientation of the needle as well as its future trajectory, integrated with the live ultrasound image. Both needle and ultrasound scan are presented to the user in their actual spatial orientations. In Phase I, a prototype system was developed and its efficacy tested. The results were stunning: two expert users increased their placement accuracy from 60% without our guidance to 100% with it; while two novice users (who had never before held an ultrasound probe) improved from 5% accuracy without our guidance to 100% with it. In other words, the novice users were not able to place the needle into a feature in the LUT video without our system, and with it they could not miss. In this Phase II project, we propose to (1) investigate new capabilities that will increase the usefulness of the system; and (2) to continue refinement of the prototype so that, at the project's conclusion, it will be ready for clinical trials with human subjects. It will be tested both quantitatively and qualitatively in multiple animal studies. We will also test its usability in a clinical setting, as well as experimentally evaluate the usefulness of the novel features developed throughout Phase II.
PUBLIC HEALTH RELEVANCE: We propose to develop an advanced stereoscopic visualization system for minimally-invasive surgery that facilitates the use of laparoscopic ultrasound during MIS interventions, in order to reduce patient injury rates. The system offers three-dimensional guidance for accurate placement of needles or other interventional instruments into structures seen in the laparoscopic ultrasound image, so that the surgeon can conduct the procedure more easily and more safely.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Registered Ultrasound-Endoscope
-
批准号:7993881
-
项目类别:
-
资助金额:$37.99万
-
财政年份:2010
-
负责人:Sharif Razzaque
-
依托单位:
A Needle Guidance System for Hepatic Tumor Ablation That Fuses Real-Time Ultrasou
-
批准号:8463473
-
项目类别:
-
资助金额:$54.73万
-
财政年份:2009
-
负责人:Sharif Razzaque
-
依托单位:
A Needle Guidance System for Hepatic Tumor Ablation That Fuses Real-Time Ultrasou
-
批准号:7671127
-
项目类别:
-
资助金额:$14.97万
-
财政年份:2009
-
负责人:Sharif Razzaque
-
依托单位:
A Needle Guidance System for Hepatic Tumor Ablation That Fuses Real-Time Ultrasou
-
批准号:8314235
-
项目类别:
-
资助金额:$65.28万
-
财政年份:2009
-
负责人:Sharif Razzaque
-
依托单位:
Registered Ultrasound-Endoscope
-
批准号:7670135
-
项目类别:
-
资助金额:$9.95万
-
财政年份:2009
-
负责人:Sharif Razzaque
-
依托单位:
海外基金