Early vascular response of ultra-thin bioresorbable polymer sirolimus-eluting stents assessed by optical frequency domain imaging: the EVALUATION study
Early vascular response of ultra-thin bioresorbable polymer sirolimus-eluting stents assessed by optical frequency domain imaging: the EVALUATION study
复制标题
通过光频域成像评估超薄生物可吸收聚合物西罗莫司洗脱支架的早期血管反应:评估研究
DOI:
10.1007/s12928-020-00689-9
复制
发表时间:
2020
影响因子:
3.2
通讯作者:
Kuwahara Koichiro
中科院分区:
文献类型:
--
作者:
Miura Takashi;Ueki Yasushi;Senda Keisuke;Otagiri Kyuhachi;Tachibana Takahiro;Saigusa Tatsuya;Ebisawa Soichiro;Motoki Hirohiko;Ikeda Uichi;Kuwahara Koichiro
This study aimed to evaluate the early vascular response of ultra-thin strut bioresorbable polymer sirolimus-eluting stents (BP SES) using optical frequency domain imaging (OFDI). Ultra-thin strut BP SES have superior outcomes in terms of efficacy and safety endpoints when compared to other thin strut new-generation stents. However, the factors contributing to the superiority of BP SES over other thin strut new-generation stents are unclear. A total of 32 patients with multivessel disease requiring staged procedures at 1 month were enrolled from 3 cardiovascular institutions; of these, 31 were immediately assessed by OFDI (n= 31). All patients were assessed at 1 month after ultra-thin strut BP SES implantation. The primary endpoint was % of uncovered struts. A total of 1723 cross sections (17,014 struts) were analyzed at baseline and 1 month after percutaneous coronary intervention. The % uncovered struts at 1-month follow-up was 7.7% (4.0, 13.8). Furthermore, the covered strut % (88.4% and 80.4%,P= 0.013) and malapposition rate (2.7% and 4.3%,P= 0.012) were significantly different between the 60-μm and 80-μm stents. Ultra-thin strut BP SES implantation may feasibly achieve early vascular responses due to the ultra-thin struts. This may ultimately lead to lower stent thrombosis and target lesion failure rates.Clinical trial registrationUniversity Hospital Medical Information Network Clinical Trials Registry (No. UMIN000033406).
登录
查看更多内容
影响因子:
5.4
作者:
Zbinden R;Piccolo R;Heg D;Roffi M;Kurz DJ;Muller O;Vuilliomenet A;Cook S;Weilenmann D;Kaiser C;Jamshidi P;Franzone A;Eberli F;Jüni P;Windecker S;Pilgrim T
通讯作者:
Pilgrim T
影响因子:
37.8
作者:
Bangalore, Sripal;Toklu, Bora;Stone, Gregg W.
通讯作者:
Stone, Gregg W.
DOI:
10.1016/j.cjca.2019.07.633
发表时间:
2019
期刊:
The Canadian journal of cardiology
影响因子:
--
作者:
T. Shinke;T. Itoh;M. Ishida;H. Otake;D. Terashita;T. Fusazaki;T. Kikuchi;T. Okamura;T. Morita;Takatoshi Hayashi;T. Sawada;Y. Yasaka;Takumi Inoue;Akira Matsuura;M. Kawata;A. Kozuki;J. Shite;T. Kataoka;K. Hibi;S. Ishihara;T. Akasaka;T. Kubo;Y. Ino;S. Sonoda;Jungo Furuya;Teppei Sugaya;Yoshisato Shibata;N. Kuriyama;N. Igarashi;Daisuke Matsumoto;Noritoshi Hiranuma;Yoritaka Otsuka;Y. Morino
通讯作者:
Y. Morino
影响因子:
4.8
作者:
Kitabata, Hironori;Kubo, Takashi;Akasaka, Takashi
通讯作者:
Akasaka, Takashi
DOI:
10.1016/j.ijcha.2018.08.001
发表时间:
2018-09
期刊:
International journal of cardiology. Heart & vasculature
影响因子:
--
作者:
Sato T;Taya Y;Suzuki N;Yuasa S;Kishi S;Koshikawa T;Fuse K;Fujita S;Ikeda Y;Kitazawa H;Takahashi M;Okabe M;Aizawa Y
通讯作者:
Aizawa Y