Acoustic Mist Ionization Mass Spectrometry for Ultrahigh-Throughput Metabolomics Screening.
Acoustic Mist Ionization Mass Spectrometry for Ultrahigh-Throughput Metabolomics Screening.
复制标题
DOI:
10.1021/acs.analchem.1c01616
复制
发表时间:
2021-07-06
影响因子:
7.4
通讯作者:
Viant MR
中科院分区:
文献类型:
--
作者:
Smith MJ;Ivanov DP;Weber RJM;Wingfield J;Viant MR
Incorporating safety data early in the drug discovery pipeline is key to reducing costly lead candidate failures. For a single drug development project, we estimate that several thousand samples per day require screening (<10 s per acquisition). While chromatography-based metabolomics has proven value at predicting toxicity from metabolic biomarker profiles, it lacks sufficiently high sample throughput. Acoustic mist ionization mass spectrometry (AMI–MS) is an atmospheric pressure ionization approach that can measure metabolites directly from 384-well plates with unparalleled speed. We sought to implement a signal processing and data analysis workflow to produce high-quality AMI–MS metabolomics data and to demonstrate its application to drug safety screening. An existing direct infusion mass spectrometry workflow was adapted, extended, optimized, and tested, utilizing three AMI–MS data sets acquired from technical and biological replicates of metabolite standards and HepG2 cell lysates and a toxicity study. Driven by criteria to minimize variance and maximize feature counts, an algorithm to extract the pulsed scan data was designed; parameters for signal-to-noise-ratio, replicate filter, sample filter, missing value filter, and RSD filter were all optimized; normalization and batch correction strategies were adapted; and cell phenotype filtering was implemented to exclude high cytotoxicity samples. The workflow was demonstrated using a highly replicated HepG2 toxicity data set, comprising 2772 samples from exposures to 16 drugs across 9 concentrations and generated in under 5 h, revealing metabolic phenotypes and individual metabolite changes that characterize specific modes of action. This AMI–MS workflow opens the door to ultrahigh-throughput metabolomics screening, increasing the rate of sample analysis by approximately 2 orders of magnitude.
登录
查看更多内容
影响因子:
7.4
作者:
Guillaume-Gentil, Orane;Rey, Timo;Vorholt, Julia A.
通讯作者:
Vorholt, Julia A.
影响因子:
2.1
作者:
Zhang, Xing;Romm, Michelle;Baker, Erin S.
通讯作者:
Baker, Erin S.
影响因子:
6.1
作者:
Ramirez T;Strigun A;Verlohner A;Huener HA;Peter E;Herold M;Bordag N;Mellert W;Walk T;Spitzer M;Jiang X;Sperber S;Hofmann T;Hartung T;Kamp H;van Ravenzwaay B
通讯作者:
van Ravenzwaay B
DOI:
10.2174/138620709789104924
发表时间:
2009-09-01
影响因子:
1.8
作者:
Jonas, Maxine;LaMarr, William A.;Ozbal, Can
通讯作者:
Ozbal, Can
影响因子:
2
作者:
Donegan, M;Tomlinson, AJ;Juhasz, P
通讯作者:
Juhasz, P