60-S Retrogated Compressed Sensing 2D Cine of the Heart: Sharper Borders and Accurate Quantification.
60-S Retrogated Compressed Sensing 2D Cine of the Heart: Sharper Borders and Accurate Quantification.
复制标题
DOI:
10.3390/jcm10112417
复制
发表时间:
2021-05-29
影响因子:
3.9
通讯作者:
Pontana F
中科院分区:
文献类型:
--
作者:
Longère B;Gkizas CV;Coisne A;Grenier L;Silvestri V;Pagniez J;Simeone A;Hennicaux J;Schmidt M;Forman C;Toupin S;Montaigne D;Pontana F
Background and objective: Real-time compressed sensing cine (CSrt) provides reliable quantification for both ventricles but may alter image quality. The aim of this study was to assess image quality and the accuracy of left (LV) and right ventricular (RV) volumes, ejection fraction and mass quantifications based on a retrogated segmented compressed sensing 2D cine sequence (CSrg). Methods: Thirty patients were enrolled. Each patient underwent the reference retrogated segmented steady-state free precession cine sequence (SSFPref), the real-time CSrt cine and the segmented retrogated prototype CSrg sequence providing the same slices. Functional parameters quantification and image quality rating were performed on SSFPref and CSrg images sets. The edge sharpness, which is an estimate of the edge spread function, was assessed for the three sequences. Results: The mean scan time was: SSFPref = 485.4 ± 83.3 (SD) s (95% CI: 454.3–516.5) and CSrg = 58.3 ± 15.1 (SD) s (95% CI: 53.7–64.2) (p < 0.0001). CSrg subjective image quality score (median: 4; range: 2–4) was higher than the one provided by CSrt (median: 3; range: 2–4; p = 0.0008) and not different from SSFPref overall quality score (median: 4; range: 2–4; p = 0.31). CSrg provided similar LV and RV functional parameters to those assessed with SSFPref (p > 0.05). Edge sharpness was significantly better with CSrg (0.083 ± 0.013 (SD) pixel−1; 95% CI: 0.078–0.087) than with CSrt (0.070 ± 0.011 (SD) pixel−1; 95% CI: 0.066–0.074; p = 0.0004) and not different from the reference technique (0.075 ± 0.016 (SD) pixel−1; 95% CI: 0.069–0.081; p = 0.0516). Conclusions: CSrg cine provides in one minute an accurate quantification of LV and RV functional parameters without compromising subjective and objective image quality.
登录
查看更多内容
DOI:
10.1186/1532-429x-15-55
发表时间:
2013-06-20
期刊:
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
影响因子:
--
作者:
Klinke V;Muzzarelli S;Lauriers N;Locca D;Vincenti G;Monney P;Lu C;Nothnagel D;Pilz G;Lombardi M;van Rossum AC;Wagner A;Bruder O;Mahrholdt H;Schwitter J
通讯作者:
Schwitter J
影响因子:
3.3
作者:
Feng, Li;Srichai, Monvadi B.;Lim, Ruth P.;Harrison, Alexis;King, Wilson;Adluru, Ganesh;Dibella, Edward V. R.;Sodickson, Daniel K.;Otazo, Ricardo;Kim, Daniel
通讯作者:
Kim, Daniel
影响因子:
5.7
作者:
Knauth, A. L.;Gauvreau, K.;Geva, T.
通讯作者:
Geva, T.
影响因子:
6.7
作者:
Haubenreisser, Holger;Henzler, Thomas;Papavassiliu, Theano
通讯作者:
Papavassiliu, Theano
影响因子:
1.3
作者:
Goebel, Juliane;Nensa, Felix;Nassenstein, Kai
通讯作者:
Nassenstein, Kai