FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0.
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0.
复制标题
DOI:
10.1007/s00259-014-2961-x
复制
发表时间:
2015-02
影响因子:
9.1
通讯作者:
Krause, Bernd J.
中科院分区:
文献类型:
--
作者:
Boellaard, Ronald;Delgado-Bolton, Roberto;Oyen, Wim J. G.;Giammarile, Francesco;Tatsch, Klaus;Eschner, Wolfgang;Verzijlbergen, Fred J.;Barrington, Sally F.;Pike, Lucy C.;Weber, Wolfgang A.;Stroobants, Sigrid;Delbeke, Dominique;Donohoe, Kevin J.;Holbrook, Scott;Graham, Michael M.;Testanera, Giorgio;Hoekstra, Otto S.;Zijlstra, Josee;Visser, Eric;Hoekstra, Corneline J.;Pruim, Jan;Willemsen, Antoon;Arends, Bertjan;Kotzerke, Joerg;Bockisch, Andreas;Beyer, Thomas;Chiti, Arturo;Krause, Bernd J.
The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings.
登录
查看更多内容
影响因子:
5.9
作者:
Coulden, Richard;Chung, Peter;Abele, Jon
通讯作者:
Abele, Jon
DOI:
10.1016/j.ijrobp.2006.03.015
发表时间:
2006-08-01
影响因子:
7
作者:
Andrade, Regiane S.;Heron, Dwight E.;Avril, Norbert
通讯作者:
Avril, Norbert
影响因子:
9.3
作者:
Boellaard, Ronald
通讯作者:
Boellaard, Ronald
影响因子:
9.3
作者:
Coleman, R. Edward;Hillner, Bruce E.;Siegel, Barry A.
通讯作者:
Siegel, Barry A.
影响因子:
8.4
作者:
Borst, GR;Belderbos, JSA;Lebesque, JV
通讯作者:
Lebesque, JV