EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras.

EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras.
复制标题

DOI:
10.1186/s41824-019-0058-2
复制
发表时间:
2019-07-02
影响因子:
1.7
通讯作者:
Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)
Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)
中科院分区:
其他
文献类型:
--
作者:
Hyafil F;Gimelli A;Slart RHJA;Georgoulias P;Rischpler C;Lubberink M;Sciagra R;Bucerius J;Agostini D;Verberne HJ;Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)

文献摘要

参考文献

被引文献

相似文献

欧洲越来越多的核医学中心正在使用以心脏为中心的伽马相机进行心肌灌注造影(MPS)。目前在欧洲最常用的有三种心脏中心伽马相机:D-SPECT(Spectrum Dynamics)、Alcyone(Discovery NM 530 c和Discovery NM/CT 570 c; General Electric Medical Systems)和IQ-SPECT(Siemens Healthcare)。这三种以心脏为中心的系统的心肌计数灵敏度增加,使得注射给患者进行心肌灌注成像的放射性药物的活性降低,从而降低了患者的辐射暴露。在制定MPS方案时,总体目标应是保持MPS的高诊断准确性,同时注入可合理实现的最低放射性,以降低患者和工作人员的辐射暴露水平。这些指南旨在为使用心脏中心相机的采集协议和图像解释提供建议。由于每种成像系统都具有特定的图像采集和分析设计和功能,因此针对每种伽马相机系统,这些指南分为三个部分。这些建议由EANM心血管委员会的成员撰写,并基于他们自己对这些系统的经验和现有文献。
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
DOI: 10.1007/s00259-011-1877-y
发表时间: 2011-11-01
影响因子: 9.1
作者:
Fiechter, Michael;Ghadri, Jelena R.;Kaufmann, Philipp A.
通讯作者: Kaufmann, Philipp A.
DOI: 10.1093/ehjci/jev312
发表时间: 2016-09-01
影响因子: 6.2
作者:
Caobelli, Federico;Akin, Muharrem;Bengel, Frank M.
通讯作者: Bengel, Frank M.
DOI: 10.1007/s12350-013-9827-7
发表时间: 2014-02-01
影响因子: 2.4
作者:
Esteves, Fabio P.;Galt, James R.;Garcia, Ernest V.
通讯作者: Garcia, Ernest V.
DOI: 10.1007/s00259-013-2505-9
发表时间: 2013-12-01
影响因子: 9.1
作者:
Giorgetti, Assuero;Masci, Pier Giorgio;Marzullo, Paolo
通讯作者: Marzullo, Paolo