Carbon monofilament electrodes for unit recording and functional MRI in same subjects.

Carbon monofilament electrodes for unit recording and functional MRI in same subjects.
复制标题

DOI:
10.1016/j.neuroimage.2018.10.082
复制
发表时间:
2019-02-01
期刊:
影响因子:
5.7
通讯作者:
Lee JH
Lee JH
中科院分区:
医学1区
文献类型:
--
作者:
Chuapoco MR;Choy M;Schmid F;Duffy BA;Lee HJ;Lee JH

文献摘要

参考文献

被引文献

相似文献

Extracellular electrophysiology and functional MRI are complementary techniques that provide information about cellular and network-level neural activity, respectively. However, electrodes for electrophysiology are typically made from metals, which cause significant susceptibility artifacts on MR images. Previous work has demonstrated that insulated carbon fiber bundle electrodes reduce the volume of magnetic susceptibility artifacts and can be used to record local field potentials (LFP), but the relatively large diameter of the probes make them unsuitable for multi- and single-unit recordings. Although single carbon fiber electrodes have recently been used to record single-unit activity, these probes require modifications in order to aid insertion and the use of these probes in fMRI has yet to be validated. Therefore, there is a need for a single-carbon fiber electrode design that (1) minimizes the volume of the susceptibility artifact, (2) can record from a wide frequency band that includes LFP and multi- and single-unit recording, and (3) is practical to insert without additional modifications. Here, we demonstrate that carbon-fiber electrodes made from single carbon monofilaments (35 μm in diameter) meet all of these criteria. Carbon monofilament electrodes modified with the conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) have lower impedances and higher signal-to-noise ratio recordings than platinum-iridium electrodes, a current gold standard for chronic single-unit recording. Furthermore, these probes distort a significantly smaller volume of voxels compared to tungsten and platinum-iridium electrodes in agarose phantom and in vivo MR images, leading to higher contrast-to-noise ratio in regions proximal to the electrode implantation site during fMRI. Collectively, this work establishes that carbon monofilaments are a practical choice for combined electrophysiology-fMRI experiments.
DOI: 10.1016/j.brainres.2013.03.011
发表时间: 2013-05-20
期刊: Brain research
影响因子: 2.9
作者:
Kahn I;Knoblich U;Desai M;Bernstein J;Graybiel AM;Boyden ES;Buckner RL;Moore CI
通讯作者: Moore CI
DOI: 10.1002/mrm.22508
发表时间: 2010-10
影响因子: 3.3
作者:
Airaksinen, Antti M.;Niskanen, Juha-Pekka;Chamberlain, Ryan;Huttunen, Joanna K.;Nissinen, Jan;Garwood, Michael;Pitkanen, Asia;Grohn, Olli
通讯作者: Grohn, Olli
细胞外田地和电流的起源-EEG,ECOG,LFP和尖峰。
DOI: 10.1038/nrn3241
发表时间: 2012-05-18
期刊: Nature reviews. Neuroscience
影响因子: --
作者:
Buzsáki G;Anastassiou CA;Koch C
通讯作者: Koch C
DOI: 10.1114/1.1581292
发表时间: 2003-07-01
影响因子: 3.8
作者:
Geddes, LA;Roeder, R
通讯作者: Roeder, R
DOI: 10.1088/1741-2560/10/4/046016
发表时间: 2013-08
影响因子: 4
作者:
Guitchounts G;Markowitz JE;Liberti WA;Gardner TJ
通讯作者: Gardner TJ