Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.
Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.
复制标题
DOI:
10.2967/jnumed.109.069112
复制
发表时间:
2010-09
期刊:
影响因子:
--
通讯作者:
Sorensen AG
中科院分区:
文献类型:
--
作者:
Catana C;van der Kouwe A;Benner T;Michel CJ;Hamm M;Fenchel M;Fischl B;Rosen B;Schmand M;Sorensen AG
A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. An MR-DUTE-based AC method was implemented considering all these factors and our preliminary results suggest that this method could potentially be as accurate as the segmented CT method and it could be used for quantitative neurological MR-PET studies.
登录
查看更多内容
影响因子:
1.8
作者:
Watson, CC
通讯作者:
Watson, CC
影响因子:
9.3
作者:
Hofmann, Matthias;Steinke, Florian;Pichler, Bernd J.
通讯作者:
Pichler, Bernd J.
影响因子:
82.9
作者:
Judenhofer, Martin S.;Wehrl, Hans F.;Pichler, Bernd J.
通讯作者:
Pichler, Bernd J.
影响因子:
19.7
作者:
Schlemmer, Heinz-Peter W.;Pichler, Bernd J.;Claussen, Claus D.
通讯作者:
Claussen, Claus D.
影响因子:
5.7
作者:
Fischl, B;Salat, DH;Dale, AM
通讯作者:
Dale, AM