The development of two-dimensional position-sensitive counter for high-energy X rays provided from synchrotron radiation facility
The development of two-dimensional position-sensitive counter for high-energy X rays provided from synchrotron radiation facility
批准号:
06452071
负责人:
ITO Shin
金额:
$3.52万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for General Scientific Research (B)
财政年份:
1994
资助国家:
日本
项目状态:
已结题
起止时间:
1994 至 1995
中文摘要
点击翻译按钮获取中文摘要
英文摘要
In this research, we have made basic studies for the development of two-dimensional position-sensitive detector for high energy X rays of 10 - 100keV range, being based on the drift chamber principle. Our achievements are as follows :1) Operational mechanism of high-pressure proportional counter in the region of limited proportionality (RLP) (a) Detailed analysis was performed for the halo effect due to characteristic X rays, and the response of proportional counter caused by this effect was fully explained. It was first found that, in RLP,the degree of gas amplification for the halo events is greater than that for the photo-peak events. From the practical view-point, this fact helps since a simple pulse-height selection is able to exclude the halo events which is known to deteriorate position resolution. The results are published in the article No. (1). (b) It was confirmed that the sudden change of avalanche mode due to structural change of primary-electron cloud exists in 7-atm Ar+3 … More 0% CH_4. (the article No. (2)) (c) The feasibility of our position-sensitive proportional counter (PSPC) was examined in charged-particle accelerator experiment. The result showed that high-energy (position) resolving power of the PSPC enables to analyze trace elements to be studied in PIXE.(the article No. (4)) The performance of the PSPC for 10-60 KeV high-energy photon beams was tested in KEK Photon Factory. Fairly good position resolution of 122mum (fwhm) for 20-keV X rays and 140mum for 35-keV X rays were obtained. A part of the results is given in the article No. (3).2) Fabrication of drift detector for X rays (a) A drift detector for X rays with a large sensitive area of 110 x 110 mm^2 was made. The drift space consists of field wires of 25 layrs in drift direction and 4 laryers in counter-depth direction. 4 anode wires are extended for the 4 layrs, the thicknesses of which are 2,4,6 and 8 mm, respectively. (b) The potential distribution was calculated and the adequate flat potential for the 6-mm layr is realized. It was found that the distribution of the potential near the anode wire is important to efficiently collect primary electrons. (c) Test experiments of the drift counter were carried out by using 5-7 Mev proton beams. Owing to the window materials such as Kapton films, fine collimation of the beam was not possible. The beam broadening is peculiar aspect for the charged particles, but not the case for X rays. Thus, it is hoped that, in the well-collimated photon beam experiment scheduled in this June, much better result can be obtained. Less
期刊论文(28)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Shin Ito: "Development of Position-Sensitive Proportional Counter for High-Resolution X-Ray Measurement" Activity Report of Tandem van de Graaff Accelerator 1995, Department of Physics, Faculty of Science, Kyoto University. (in press).
Shin Ito:“用于高分辨率 X 射线测量的位置敏感比例计数器的开发”1995 年 Tandem van de Graaff 加速器活动报告,京都大学理学院物理系。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Shin Ito: "Characteristic Counter Response of Position-Sensitive Proportional Counter Filled with High-Pressure Counting Gases" KEK Photon Factory Activity Report. 1993. 429 (1994)
Shin Ito:“充满高压计数气体的位置敏感比例计数器的特征计数器响应”KEK Photon 工厂活动报告。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Shin Ito: "Gas ampliffication of proportional and SOS modes observed as a function of the radial distance of the position of primary innization" Nucl.Instr.and Meth. A348. 297-302 (1994)
Shin Ito:“观察到比例和 SOS 模式的气体放大作为初级内化位置的径向距离的函数”Nucl.Instr.and Meth。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Shin Ito: "Effect of self-induced space charge in a high pressure position-sensitive proportional counter" Nucl. Instr. and Meth.A368. 738-744 (1996)
Shin Ito:“高压位置敏感正比计数器中自感空间电荷的效应”Nucl。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Shin Ito: "Gas amplification of proportional and SQS modes observed as a function of the radial distance of the position of primary ionization" Nucl. Instr. and Meth.A348. 297-302 (1994)
Shin Ito:“观察到的比例和 SQS 模式的气体放大作为初级电离位置的径向距离的函数”Nucl。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 6 条
Building a Learning Environment for Music Education that Respects Cultural Diversity in Germany
-
批准号:19K02761
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.75万
-
财政年份:2019
-
负责人:ITO Shin
-
依托单位:
Niban expression of multistep head and neck squamous cell carcinogenesis
-
批准号:23791935
-
项目类别:Grant-in-Aid for Young Scientists (B)
-
资助金额:$2.66万
-
财政年份:2011
-
负责人:ITO Shin
-
依托单位:
The analysis of high coagulant microparticles on venous thromboembolism complicated with ovarian cancer
-
批准号:23790633
-
项目类别:Grant-in-Aid for Young Scientists (B)
-
资助金额:$2.83万
-
财政年份:2011
-
负责人:ITO Shin
-
依托单位:
Academic Achievement inGerman Music Education
-
批准号:22730709
-
项目类别:Grant-in-Aid for Young Scientists (B)
-
资助金额:$1.58万
-
财政年份:2010
-
负责人:ITO Shin
-
依托单位:
Study of satellite structure of the rare-earth Lγ x rays reflecting many-electron effect of 4f-electronic state
-
批准号:14550051
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.79万
-
财政年份:2002
-
负责人:ITO Shin
-
依托单位:
Development of a 2-dim. position-sensitive detector for high-energy x rays from SR
-
批准号:09559010
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$6.66万
-
财政年份:1997
-
负责人:ITO Shin
-
依托单位:
The development of gas-sealed type position-sensitive counter utilizing peculiar electron-avalanche mode
-
批准号:06559009
-
项目类别:Grant-in-Aid for Scientific Research (A)
-
资助金额:$3.97万
-
财政年份:1994
-
负责人:ITO Shin
-
依托单位:
海外基金