Development and clinical application of non-invasive cardiac output measurement in dogs and cats
Development and clinical application of non-invasive cardiac output measurement in dogs and cats
批准号:
16580267
负责人:
YAMASHITA Kazuto
金额:
$2.18万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2004
资助国家:
日本
项目状态:
已结题
起止时间:
2004 至 2005
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Maintaining optimal cardiac output (CO) is an important goal of intraoperative hemodynamic management. The development of non-invasive methods for determining CO provides a potential solution to this goal. In this study, partial carbon dioxide rebreathing indirect Fick technique (NICO system) was evaluated for non-invasive CO measurementCO determined using NICO system (NICO) and thermodilution (TDCO) were compared in sevoflurane anesthetized 6 beagle dogs (body weight : 9.1-13.0kg). Thirty paired measurements of TDCO and NICO were collected during low, intermediate, and high values of CO achieved by varying the depth of anesthesia and the administration of dobutamine. The CO values ranged from 0.70-2.60L/min for NICO compared to 0.89-4.45L/min for TDCO. There was good correlation between TDCO and NICO (r=0.883, p<0.0001). The limits of agreement and relative bias were -1.04±0.54L/min (±56.2%) and -39.9±11.6%. In conclusion, NICO provided a low agreement to TDCO in beagle dogs.NICO system was evaluated in 89 large-breed dogs (body weight : 20.0-67.6kg) anesthetized for surgery. The dogs were classified into three groups : breathed spontaneously and maintained adequate arterial blood pressure (ABP) before skin incision (SB, n=23), required artificial ventilation to control respiratory depression and maintained adequate ABP (CV, n=52), or required artificial ventilation and showed hypotension (Hypo-CV, n=14). Cardiac index (CI) in Hypo-CV (62±13ml/min/kg) were significantly lower than SB (97±27ml/min/kg, p<0.001) and CV (84±26ml/min/kg, p=0.004). The CI in Hypo-CV increased significantly after the treatment for hypotension (79±19ml/min/kg, p<0.001). Changes in CI agreed with changes in ABP. In conclusion, NICO system is a useful method for non-invasive cardiac output monitoring during anesthesia in large-breed dogs. We recommend the value of 0.1 L/min/kg as a standard NICO value for adequate cardiac in anesthetized large-breed dogs.
期刊论文(4)
专著(0)
科研奖励(0)
会议论文
Non-invasive Determination of Cardiac Output by Transthoracic Bioimpedance,Partial Carbon Dioxide Rebreathing,and Transesophageal Doppler Echocardiography in Beagle Dogs
比格犬经胸生物阻抗、部分二氧化碳再呼吸和经食管多普勒超声心动图无创测定心输出量
DOI:
--
发表时间:
2006
期刊:
Journal of Veterinary Medical Sciences 68(審査中)
影响因子:
--
作者:
[Bartolome JA, Kamimura S, et al., 佐藤れえ子, Kazuto Yamashita]
通讯作者:
Kazuto Yamashita
Non-invasive Determination of Cardiac Output by Transthoracic Bioimpedance, Partial Carbon Dioxide Rebreathing, and Transesophageal Doppler Echocardiography in Beagle Dogs
通过经胸生物阻抗、部分二氧化碳再呼吸和经食管多普勒超声心动图对比格犬的心输出量进行无创测定
DOI:
--
发表时间:
2006
期刊:
Journal of Veterinary Medical Science 68(under review)
影响因子:
--
作者:
[Kazuto YAMASHITA, Yukie UEYAMA, Kenjiro MIYOSHI, Ritsuyo IGARASHI, Tokiko KUSHIRO, Mohammed A.UMAR, William W. Muir.]
通讯作者:
William W. Muir.
Development of general anesthesia method of horse environmentally friendly kind to animals project.
-
批准号:22580366
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.33万
-
财政年份:2010
-
负责人:YAMASHITA Kazuto
-
依托单位:
海外基金