Application of tuned-Aperture Computed Tomography in dentistry
Application of tuned-Aperture Computed Tomography in dentistry
批准号:
12671839
负责人:
YAMAMOTO Kazuhiro
金额:
$0.7万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2000
资助国家:
日本
项目状态:
已结题
起止时间:
2000 至 2001
中文摘要
点击翻译按钮获取中文摘要
英文摘要
To compare depth discrimination by using Tuned-Aperture Computed Tomography (TACT) variously beam projection arrays. Beam projection geometry is important for the accurate depth discrimination of TACT reconstructed images. A conical beam array is ideal.To compare the diagnostic information yield of interactive TACTslices and conventional dento-alveolar images for the imaging and localization of impacted maxillary incisor teeth.With IB approval, 20 patients were examined. TACT image sets were compared for diagnostic utility against available conventional radiographs including periapical, occlusal, rotational panoramic and/or lateral cephalograms. Sixteen dentists independently evaluated the image clarity of the impacted tooth and selected surrounding anatomic details. Estimation of confidence in clinical assessment was made together with determination of TACT's potential for effecting treatment plan modifications. Both TACT slices were studied. The number of component projections per TA … More CT reconstruction was either five or six a conical beam-projection array was employed in every case. The fiduciary marker was an X-Spot lead pellet (Beekley, USA). The detector was an VG-ui (Trophy adiology, France/Yoshida Dental Corporation, Japan).TACT significantly improved depiction of the buccal/palatal position of the impacted tooth and its relationship with adjacent teeth (p〈0.0001)irrespective of the availability of lateral cephalograms. Subjective assessments for clinical decision-making approximated a 10% increase in confidence ratings with TACT. The added diagnostic yield with TACT varied from case to case. Morphology and position of vertically impacted teeth were clearly demonstrated by TACT ; however, horizontal impadtions occasioned less perceived information gain.Interactive 2D TACT slices were perceived to be diagnostically more informative for assessing impacted maxillary incisor teeth and their relation to surrounded tissues than conventional methods in some but not all cases. TACT occasionally altered treatment option selection. Less
期刊论文(17)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
山本, 一普: "Tuned-Aperture Computed Tomography(TACT^【○!R】)の歯科臨床応用"歯科放射線. 42・2. (2002)
山本一风:“调谐孔径计算机断层扫描的临床牙科应用(TACT^【○!R】)”牙科放射学(2002)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Hayakawa, Yoshihiko: "Improvement in digital readout methods and advanced・・・・・"Radiology. 217. 655 (2000)
Hayakawa, Yoshihiko:“数字读出方法的改进和先进......”放射学。217. 655 (2000)
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
山本一普: "Evaluation of tuned-aperture computed tomography depth discrimination........"Oral surg Oral Med Oral Pathol Oral Radiol Endod. 89・6. 766-770 (2000)
Kazufu Yamamoto:“调谐孔径计算机断层扫描深度辨别的评估......”口腔外科 Oral Med Oral Pathol Oral Radiol Endod 89・6(2000)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Kazuhiro, Yamamoto: "Evaluation of Diagnostic Information Yield Obtained from Tuned-Aperture Computed Tomography and Conventional Dento-alveolar Imaging Modalities for Assessing Impacted Teeth"Radiology. 221. 689 (2001)
Kazuhiro, Yamamoto:“评估从调谐孔径计算机断层扫描和传统牙槽成像方式获得的诊断信息产量,用于评估受影响的牙齿”放射学。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Farman, A.G.: "Tuned-Aperture Computed Tomography accuracy in tomosynthetic assessment for dental procedures"Computer assisted radiology and surgery CARS 2001. 654-658 (2001)
Farman, A.G.:“牙科手术断层合成评估中的调谐孔径计算机断层扫描准确性”计算机辅助放射学和外科手术 CARS 2001. 654-658 (2001)
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 17 条
Practical use of the muon profile monitor using diamond for the high-intensity neutrino experiment
-
批准号:24540307
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.24万
-
财政年份:2012
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
A Study of turbulent flame structure and extinction mechanism by laser diagnostics
-
批准号:23560223
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.33万
-
财政年份:2011
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Commercially adaptable technology on shallow junction of silicon by ultra-low energy ion implantation
-
批准号:21560381
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.5万
-
财政年份:2009
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Testing gravity theory on the cosmological scales using the next generation dark energy surveys
-
批准号:21540270
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.83万
-
财政年份:2009
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Simulation on Gas-Solid Heat Transfer in Diesel Combustion
-
批准号:20560188
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.0万
-
财政年份:2008
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
On the relationship among human capital accumulation, innovation and international trade
-
批准号:19730176
-
项目类别:Grant-in-Aid for Young Scientists (B)
-
资助金额:$1.95万
-
财政年份:2007
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Development of ultra-low energy ion implantation of silicon for ultra-shallow junction
-
批准号:19560330
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.33万
-
财政年份:2007
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Study on future galaxy redshift survey for testing dark energy
-
批准号:18540277
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.39万
-
财政年份:2006
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Development of ultra shallow doping of semiconductors by ultra low energy ion beams
-
批准号:17560299
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.79万
-
财政年份:2005
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Gene expression profiling in hypertrophied heart as the determinant of phenotype of heart failure
-
批准号:15590742
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.05万
-
财政年份:2003
-
负责人:YAMAMOTO Kazuhiro
-
依托单位:
Lattice Gauge Theories as Problems of Constructive Quantum Field Theory
-
批准号:10640161
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$0.83万
-
财政年份:1998
-
负责人:YAMAMOTO Kazuhiro
-
依托单位: