课题基金 / 基金详情

INTERACTION OF SPIN LABELS WITH TRANSITION METALS

INTERACTION OF SPIN LABELS WITH TRANSITION METALS
自旋标记与过渡金属的相互作用
批准号:
2391826
负责人:
Gareth R Eaton
金额:
$19.66万
依托单位国家:
美国
项目类别:
财政年份:
1977
资助国家:
美国
项目状态:
已结题
起止时间:
1977-07-01 至 2000-03-31

项目摘要

项目成果

Gareth R Eaton的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
The measurement of distances between parts of biological macromolecules, such a proteins, is a major challenge, especially for membrane-bound proteins. Our preliminary results demonstrate the feasibility of measuring the distance between two paramagnetic centers, especially in the distance range of 10-25 Angstroms, which fills the gap between the ranges in which NMR and fluorescence energy transfer are most useful. Some biomolecules have two paramagnetic centers in their native form. One or more non-native paramagnetic centers can be introduced into proteins by metal replacement, by spin labeling, or by site-directed mutagenesis to create new sites for metals and for spin labels. Thus, an EPR method for measuring distance is of general applicability. We have developed new theoretical models, confirmed by preliminary experiments on spin-labeled low-spin methemoglobin, for the measurement of distances between metals and spin labels. We have demonstrated, both theoretically and experimentally, the importance of knowing the relaxation times of the paramagnetic centers in the absence of interaction, and the dependence of the relaxation times on the position in the EPR Spectrum. We propose to extend the theory and experiments to other metal-spin states, testing the effects of metal hyperfine, g-anisotropy, and zero-field splitting (for spin> 1/2), to validate the models and find the limits of their applicability. To this end we will make mutant myoglobins with spin labels at selected distances and angular orientations relative to the heme ring, and use high-spin iron(III) and other metals in spin-labeled hemoglobin to refine the calculations. We predict that longer distances can be measured at microwave frequencies lower than the normal X-band, and we will test this prediction. The result of this research will be a validated model, and specific guidelines to other workers telling what range of distances can be measured for various pairs of paramagnetic centers, and what the uncertainties are, as a function of how much information is available for each center.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Preclinical Electron Paramagnetic Resonance Tumor Imager
Preclinical Electron Paramagnetic Resonance Tumor Imager
Preclinical Electron Paramagnetic Resonance Tumor Imager
Preclinical Electron Paramagnetic Resonance Tumor Imager
海外基金