STATISTICAL METHODS FOR ATTENUATION CORRECTION IN ECT

STATISTICAL METHODS FOR ATTENUATION CORRECTION IN ECT
ECT 衰减校正的统计方法
批准号:
2443039
负责人:
JEFFREY A FESSLER
金额:
$10.46万
依托单位国家:
美国
项目类别:
财政年份:
1993
资助国家:
美国
项目状态:
已结题
起止时间:
1993-07-01 至 1998-06-30

项目摘要

项目成果

JEFFREY A FESSLER的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
For emission computed tomography (ECT) to be quantitatively accurate and diagnostically efficacious, one must correct for the effects of photon absorption or attenuation. Since attenuation within the human thorax is nonuniform, each patient's attenuation correction factors (ACFs) are computed from a transmission scan that usually precedes the radiotracer injection. conventional methods for this computation are suboptimal, and consequently the transmission scans are inordinately long. Reducing the transmission scan time will greatly enhance the clinical utility of positron emission tomography (PET). We propose to develop, implement, and investigate improved data- processing methods that significantly reduce the transmission scan time through better utilization of the transmission measurements. To accomplish this goal, we will focus on penalized, weighted least-squares (PWLS) methods for statistical segmentation of attenuation maps. By using PWLS segmentation methods, we can directly process the transmission measurements, rather than processing an intermediate transmission image as is necessary for other methods. In addition to reducing pre-injection transmission scan time, we will investigate applying the PWLS methods to post-injection transmission measurements of the thorax. Unlike conventional methods, the PWLS methods can accommodate the contributions due to radiotracer emissions through covariance adjustments. An effective method for attenuation correction from post-injection transmission measurements would be of significant clinical value, particularly for PET oncologic imaging using delayed FDG scans.
期刊论文(9)
专著(0)
科研奖励(0)
会议论文
Emission image reconstruction for randoms-precorrected PET allowing negative sinogram values.
随机预校正 PET 的发射图像重建允许负正弦图值。
DOI: 10.1109/tmi.2004.826046
发表时间: 2004
期刊: IEEE transactions on medical imaging
影响因子: 10.6
作者: [Ahn,Sangtae, Fessler,JeffreyA]
通讯作者: Fessler,JeffreyA
A comparison of rotation- and blob-based system models for 3D SPECT with depth-dependent detector response.
具有深度相关探测器响应的 3D SPECT 的基于旋转和基于斑点的系统模型的比较。
DOI: 10.1088/0031-9155/49/11/003
发表时间: 2004
期刊: Physics in medicine and biology
影响因子: 3.5
作者: [Yendiki,A, Fessler,JA]
通讯作者: Fessler,JA
Fast Functional MRI with Sparse Sampling and Model-Based Reconstruction
Accelerated statistical image reconstruction methods for X-ray CT
Accelerated statistical image reconstruction methods for X-ray CT
Model-Based Image Reconstruction for X-ray CT in Lung Imaging