课题基金 / 基金详情

SPECIMEN CHARGING

SPECIMEN CHARGING
样品加料
批准号:
6504528
负责人:
MICHAEL B SHERMAN
金额:
$13.47万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2000
资助国家:
美国
项目状态:
已结题
起止时间:
2000-12-01 至 2001-11-30

项目摘要

项目成果

MICHAEL B SHERMAN的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
We have developed methods for the rapid detection and evaluation of the charge which builds up on biological specimens when they are examined by electron cryomicroscopy. Charging is assessed from images of protein crystals suspended in thin layers of glucose or vitreous ice. Effects of charging are manifested as an apparent increase in mass in areas illuminated by the electron beam and an effective increase in the strength of the objective lens. We assess the influence of a variety of factors related to the charging phenomena. A mechanism of charging is proposed in terms of the emission of secondary electrons upon irradiation of the specimen creating an electrostatic lens of variable strength at the specimen. This study has improved our understanding of specimen charging and demonstrated that charging can be substantially reduced by including part of the adjacent carbon film in the irradiated specimen area. This constitutes a viable strategy for high resolution imaging of specimens that are susceptible to charging. In order to deposit a layer of carbon film on the biological specimens already embedded in vitreous ice, we modified the Gatan coater by outfitting it with a new chamber that replaced ion-beam deposition with thermal evaporation of carbon rods. This chamber is larger in size to reduce thermal load on the specimens. It has an airlock to insert a cryo-specimen and a cryo-shield to protect the specimen from contamination. A separate variable transformer connected to a timer and a high-power relay allowed control of the amount of carbon evaporated onto the specimen surface. Frozen, hydrated specimens mounted in the Gatan 626 cryoholder at -168- C were inserted and coated in the modified coater with ~100  layer of carbon and transferred into a JEOL4000EX electron cryomicroscope operating at 400 kV. Ice-embedded catalase crystals prepared over holes were used as test specimens to estimate the effectiveness of coating cryospecimens with a thin carbon layer to minimize charging. The images were recorded, digitized and analyzed for their diffraction quality as shown in the IQ-plot. The plot shows reflections of IQ } 4 up to 3  resolution. Images obtained from carbon-coated catalase crystals tilted to 50- also show reflections of the same quality up to 4  resolution. These high resolution image data demonstrate the reduction of charging using our modified coater.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Center for Ultrastructural Studies of Infectious Pathogens (CUSIP)
CCD CAMERA CHARACTERIZATION FOR 400 KEV ELECTRON MICROSCOPY
  • 批准号:
    6611289
  • 项目类别:
  • 资助金额:
    $13.47万
  • 财政年份:
    2001
  • 负责人:
    MICHAEL B SHERMAN
  • 依托单位:
SPECIMEN CHARGING
  • 批准号:
    6611288
  • 项目类别:
  • 资助金额:
    $13.47万
  • 财政年份:
    2001
  • 负责人:
    MICHAEL B SHERMAN
  • 依托单位:
SPECIMEN CHARGING
  • 批准号:
    6568619
  • 项目类别:
  • 资助金额:
    $13.47万
  • 财政年份:
    2001
  • 负责人:
    MICHAEL B SHERMAN
  • 依托单位:
海外基金