Tomosynthesis for improved pulmonary nodule detection
Tomosynthesis for improved pulmonary nodule detection
批准号:
6949544
负责人:
JAMES T DOBBINS
金额:
$36.19万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1998
资助国家:
美国
项目状态:
已结题
起止时间:
1998-12-01 至 2007-07-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant):The purpose of these studies is to evaluate whether digital tomosynthesis can serve as an adjunct to conventional chest radiography for improving clinical detection of pulmonary nodules. Digital tomosynthesis augments a conventional chest exam by providing three-dimensional information through a series of longitudinal slice images. These slice images are reconstructed from a set of discrete projection images acquired at different angles, using a conventional x-ray tube and a new digital flat-panel x-ray detector. The tomosynthesized images may be viewed slice-by-slice or as a 3-D volume-rendered projection in a "virtual fluoroscopy'' viewing environment. The diagnostic benefit of tomosynthesis is the use of 3-D information to improve detection and discrimination of pulmonary nodules by eliminating the confusion of overlying structures. CT would remain the gold standard for clinical workup once nodules are detected, with tomosynthesis providing a low-dose/low-cost method for improving initial detection accuracy. Clinically the tomosynthesis images would be acquired whenever a digital PNlateral chest exam is taken, but with reduced exposure for the lateral image such that the total patient dose from the PA/lateral/tomosynthesis exam would be about comparable to the overall dose from a conventional PNlateral chest exam. It is anticipated that tomosynthesis will enable higher sensitivity and specificity for pulmonary nodule detection than conventional chest radiography alone, and hence will potentially lead to earlier detection of lung cancer, at a cost significantly less than low-dose CT.
This proposal is a competing continuation of a previous study that developed and optimized the tomosynthesis technique. The present study will conduct a clinical evaluation of tomosynthesis for pulmonary nodule detection in a cohort of human subjects with CT-proven nodules. This study will have three parts: (1) an evaluation of tomosynthesis using radiologists as observers, (2) development and evaluation of a computer-aided diagnosis (CAD) method using three-dimensional tomosynthesis data for pulmonary nodule detection, and (3) a measurement of the accuracy with which radiologists can use tomosynthesis to localize the depth and diameter of nodules. The specific aims of the project also include pilot studies to optimize the tomosynthesis method before the large-scale collection of human subject data. These pilot studies will characterize and minimize effects of patient motion, optimize the number of reconstructed planes and patient entrance exposure, and evaluate slice viewing vs volume rendering.
期刊论文(20)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
DOI:
10.1118/1.3671939
发表时间:
2012-02
期刊:
Medical physics
影响因子:
3.8
作者:
[Jiahui Wang;J. Dobbins;Qiang Li]
通讯作者:
Jiahui Wang;J. Dobbins;Qiang Li
Chest tomosynthesis: technical principles and clinical update.
胸部合成:技术原理和临床更新。
DOI:
10.1016/j.ejrad.2009.05.054
发表时间:
2009-11
期刊:
EUROPEAN JOURNAL OF RADIOLOGY
影响因子:
3.3
作者:
[Dobbins, James T., III, McAdams, H. Page]
通讯作者:
McAdams, H. Page
Stochastic noise characteristics in matrix inversion tomosynthesis (MITS).
矩阵反演断层合成 (MITS) 中的随机噪声特性。
DOI:
10.1118/1.3103399
发表时间:
2009
期刊:
Medical physics
影响因子:
3.8
作者:
[Godfrey,DevonJ, McAdams,HP, Dobbins,JamesTThird]
通讯作者:
Dobbins,JamesTThird
Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.
数字射线照相系统的有效 DQE (eDQE) 和速度:一种实验方法。
DOI:
10.1118/1.3171690
发表时间:
2009
期刊:
Medical physics
影响因子:
3.8
作者:
[Samei,Ehsan, Ranger,NicoleT, MacKenzie,Alistair, Honey,IanD, Dobbins3rd,JamesT, Ravin,CarlE]
通讯作者:
Ravin,CarlE
Evolving and experimental technologies in medical imaging.
医学成像的不断发展和实验技术。
DOI:
10.1148/radiol.2381041602
发表时间:
2006
期刊:
Radiology.
影响因子:
--
作者:
[Wolbarst,AnthonyB, Hendee,WilliamR]
通讯作者:
Hendee,WilliamR
共 7 条
Cross-disciplinary Training in Medical Physics
-
批准号:7233336
-
项目类别:
-
资助金额:$8.81万
-
财政年份:2007
-
负责人:JAMES T DOBBINS
-
依托单位:
Cross-disciplinary Training in Medical Physics
-
批准号:7870413
-
项目类别:
-
资助金额:$16.79万
-
财政年份:2007
-
负责人:JAMES T DOBBINS
-
依托单位:
Cross-disciplinary Training in Medical Physics
-
批准号:7440318
-
项目类别:
-
资助金额:$13.32万
-
财政年份:2007
-
负责人:JAMES T DOBBINS
-
依托单位:
Cross-disciplinary Training in Medical Physics
-
批准号:7609067
-
项目类别:
-
资助金额:$17.78万
-
财政年份:2007
-
负责人:JAMES T DOBBINS
-
依托单位:
Cross-disciplinary Training in Medical Physics
-
批准号:8076822
-
项目类别:
-
资助金额:$15.84万
-
财政年份:2007
-
负责人:JAMES T DOBBINS
-
依托单位:
TOMOSYNTHESIS FOR IMPROVED PULMONARY NODULE DETECTION
-
批准号:6174245
-
项目类别:
-
资助金额:$30.87万
-
财政年份:1999
-
负责人:JAMES T DOBBINS
-
依托单位:
TOMOSYNTHESIS FOR IMPROVED PULMONARY NODULE DETECTION
-
批准号:6377030
-
项目类别:
-
资助金额:$31.54万
-
财政年份:1999
-
负责人:JAMES T DOBBINS
-
依托单位:
TOMOSYNTHESIS FOR IMPROVED PULMONARY NODULE DETECTION
-
批准号:2901910
-
项目类别:
-
资助金额:$32.59万
-
财政年份:1999
-
负责人:JAMES T DOBBINS
-
依托单位:
Tomosynthesis for improved pulmonary nodule detection
-
批准号:6543161
-
项目类别:
-
资助金额:$36.19万
-
财政年份:1998
-
负责人:JAMES T DOBBINS
-
依托单位:
Tomosynthesis for improved pulmonary nodule detection
-
批准号:6783357
-
项目类别:
-
资助金额:$36.19万
-
财政年份:1998
-
负责人:JAMES T DOBBINS
-
依托单位:
Tomosynthesis for improved pulmonary nodule detection
-
批准号:6647103
-
项目类别:
-
资助金额:$36.19万
-
财政年份:1998
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL-ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:2096592
-
项目类别:
-
资助金额:$17.71万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:2330800
-
项目类别:
-
资助金额:$20.9万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL-ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:3199928
-
项目类别:
-
资助金额:$17.37万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:2654081
-
项目类别:
-
资助金额:$21.65万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:2096594
-
项目类别:
-
资助金额:$19.87万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DUAL-ENERGY SCREENING FOR NODULAR DISEASE
-
批准号:3199927
-
项目类别:
-
资助金额:$20.46万
-
财政年份:1992
-
负责人:JAMES T DOBBINS
-
依托单位:
DIGITAL CHEST RADIOGRAPHY WITH A DIGITAL BEAM ATTENUATOR
-
批准号:3447017
-
项目类别:
-
资助金额:$4.53万
-
财政年份:1986
-
负责人:JAMES T DOBBINS
-
依托单位:
DIGITAL CHEST RADIOGRAPHY WITH A DIGITAL BEAM ATTENUATOR
-
批准号:3447016
-
项目类别:
-
资助金额:$3.75万
-
财政年份:1986
-
负责人:JAMES T DOBBINS
-
依托单位:
DIGITAL CHEST RADIOGRAPHY WITH A DIGITAL BEAM ATTENUATOR
-
批准号:3447015
-
项目类别:
-
资助金额:$4.08万
-
财政年份:1986
-
负责人:JAMES T DOBBINS
-
依托单位:
海外基金