课题基金 / 基金详情

项目摘要

项目成果

Jeffrey Kapatoes的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
 DESCRIPTION (provided by applicant): Modern day radiotherapy has developed in complexity to the degree that significant treatment errors are both difficult to detect and difficut to completely avoid. In the current day radiotherapy department it is common to have a large number of patients being treated with Intensity Modulated Radiotherapy (IMRT) techniques. When treating patients with these techniques it can be difficult to detect patient setup errors and virtually impossible to detect beam collimation errors without the use of automated secondary checks. Incorrect dose delivery or dose delivered to the wrong area is also an ongoing treatment risk. Despite gains in the implementation of automated mechanisms for detection of errors the incidence of concerning treatment misadministrations is still significant. Treatment delivery errors in the modern era have been reported by several authors as occurring during from 1 to 2 % of patients' courses of treatment. While most of these are judged to not be of clinical importance, the rate of significant treatment errors is still thousands of incidents per yar in the United States alone. Compromised radiotherapy treatments can lead to lower control rates and/or higher complication rates. We will develop a system that will provide the radiotherapy clinic with the capability to completely and independently measure the geometric alignment and dosimetric compliance of an individual treatment fraction in real time as the patient is treated with any arbitrarily complex treatment technique. The system will consist of a high density cloak of radiation detectors deployed in a ring centered on the treatment apparatus isocenter and within the rotational circle of the head(s) of the radiation delivery system. The detector cloak will surround the area within the patient being treated and will measure the radiation fluence both entering and exiting the patient. The dosimetric data acquired at the time of treatment will allow for the calculation of the complete dose distribution actually delivered to the patient for each and every treatment session. The detection system will be physically and electronically independent of the treatment system thereby providing a truly comprehensive secondary monitor of the delivered dose. Development and clinical deployment of a completely independent treatment verification system for radiotherapy has the potential to significantly reduce radiotherapy treatment errors. The reduction of treatment delivery errors can increase local tumor control rates, reduce the rate of treatment complications or both. The ongoing compilation of actual treatment delivery compliance data will serve as invaluable confirmation of the benefit, or lack thereof, of newly implemented quality assurance techniques.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
A Fully Independent Real Time Treatment Verification System for Radiotherapy
  • 批准号:
    9261158
  • 项目类别:
  • 资助金额:
    $132.39万
  • 财政年份:
    2015
  • 负责人:
    Jeffrey Kapatoes
  • 依托单位:
国内基金
海外基金
层出镰刀菌氮代谢调控因子AreA 介导伏马菌素 FB1 生物合成的作用机理
  • 批准号:
    2021JJ40433
  • 项目类别:
    省市级项目
  • 资助金额:
    --
  • 批准年份:
    2021
  • 负责人:
    孙磊
  • 依托单位:
寄主诱导梢腐病菌AreA和CYP51基因沉默增强甘蔗抗病性机制解析
  • 批准号:
    32001603
  • 项目类别:
    青年科学基金项目
  • 资助金额:
    24.0万元
  • 批准年份:
    2020
  • 负责人:
    段真珍
  • 依托单位:
AREA国际经济模型的移植.改进和应用
  • 批准号:
    18870435
  • 项目类别:
    面上项目
  • 资助金额:
    2.0万元
  • 批准年份:
    1988
  • 负责人:
    史树中
  • 依托单位: